Analysis of Waveform of Partial Discharge in Air Insulation Measured by RC Detector Sinurat, Michael Stevano; Khayam, Umar
Proceeding of the Electrical Engineering Computer Science and Informatics Vol 5: EECSI 2018
Publisher : IAES Indonesia Section

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (772.794 KB) | DOI: 10.11591/eecsi.v5.1686

Abstract

This study discusses the measurement of Partial Discharge (PD) in air insulation. Partial Discharge Measurement is very important to know the condition of electrical equipment. The cause of partial discharge is not only old equipment, but also from set-up errors and insulation problems. In this research partial discharge measurement was performed by using electrical methods. Electrical method use RC Detector. The modeling of partial discharge was done by using needle-plane electrode distant 1 cm in air insulation. Partial discharge measurement parameters include the measurement of Background Noise (BGN), Partial Discharge Inception Voltage (PDIV) and PD Waveform. The Partial Discharge measurement result show that Vpp of BGN ON is higher than Vpp of BGN OFF. The negative PDIV signal first appeared for the RC Detector at a voltage 3.55 KV and Positive PDIV at 4.01 KV. Negative and positive PD waveform for RC Detector at 5 KV, 5.5 KV, 6 KV, 6.5 KV and 7 KV respectively, it has been found that the fall time is greater than the rise time, and peak to peak voltage (Vpp) will be greater when the applied voltage is greater.
Application of Ultra-Wideband Double Layer Printed Antenna for Partial Discharge Detection Hamdani, Yuda Muhammad; Khayam, Umar
Proceeding of the Electrical Engineering Computer Science and Informatics Vol 5: EECSI 2018
Publisher : IAES Indonesia Section

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (784.888 KB) | DOI: 10.11591/eecsi.v5.1690

Abstract

Partial discharge (PD) is a local electrification phenomenon that partially connects insulation between the conductors and occurs either on the surface of the conductor or inside the insulation (void). During the PD there are several phenomena that accompany the occurrence of PD, such as impulse currents, heat radiation, electromagnetic waves, mechanical waves and chemical processes. This phenomenon is detected and measured to know the existence of PD. One of the PD measurements is ultra high frequency (UHF) method, by measuring the waves generated by PD using antenna. One of antenna having good characteristics is UWB double layer printed antenna. In this paper the application of ultra-wideband double layer printed antenna for partial discharge detection is reported. The application of antenna on PD measurement, shows that the antenna is able to detect PD. The characteristics of PD: PDIV, PDEV, PD waveform are measured using this antenna. Ultra-wideband (UWB) double layer printed antenna is an antenna developed from a square microstrip antenna with symmetrical T-shaped tethering. The proposed antenna is implemented on Epoxy FR-4 substrate with permittivity of 4.3, thickness of 1.6mm, and 72.8mm x 60.0mm in size. The VNA testing of the antenna shows that the antenna bandwidth is from 50MHz to 2.30GHz. The measured results of PD wave are PDIV, PD waveform and PDEV.
Determination of Appropriate Overhead Line Insulator in Sumatra due to Contamination Severity Zaeni, Arpan; Khayam, Umar; Viviantoro, Deny
Proceeding of the Electrical Engineering Computer Science and Informatics Vol 6: EECSI 2019
Publisher : IAES Indonesia Section

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eecsi.v6.2018

Abstract

Insulator is one of the important equipment to support electrical power delivery which flow through the transmission line. Considering its very important role, the selection of insulators must be certainly based on deep analysis so that the insulator we choose works properly. There are several standards that can be used in selecting isolators, but in this paper the standards that will be used for case study analysis are IEC and IEEE standards. Case studies that will be used for the selection of insulators are for Sumatra that located in Indonesia which is a tropical country and certainly has special environmental characteristics that can influence the selection parameters of an insulator. There are several parameters that are commonly used in selecting overhead isolators those are power frequency voltage, environmental condition (contamination), switching over voltage, and lightning over voltage. Using environmental condition, it is found that the pollution category of Sumatra area is heavy, which influence the selection of insulation material.
Measurement of Partial Discharge Induced Electromagnetic Wave using Loop Antenna Khayam, Umar; Fatoni, Fendi Imam
Proceeding of the Electrical Engineering Computer Science and Informatics Vol 4: EECSI 2017
Publisher : IAES Indonesia Section

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (360.855 KB) | DOI: 10.11591/eecsi.v4.1026

Abstract

Partial discharge (PD) detection by detecting    the released   energy   in the form   of   electromagnetic (EM)   wave during discharge using Ultra-High Frequency (UHF) antenna is one of the methods to determine insulation system quality of power apparatus. The main advantage of UHF PD detection system by using antenna are the capability to detect PD signal without firstly shut down the power apparatus. Therefore, the PD measurement system based on EM wave induced by PD detected by the sensor is needed. First, the sensors which be able to detect PD induced EM wave in ultra wide band need to be designed and manufactured. Second, the characteristics of PD induced EM wave measured by the sensors need to be investigated. This paper deals with measurement of PD induced EM wave by using loop antenna. The results show that the further the distance of loop antenna to PD source is, the lower Vpp is. This is due to EM wave attenuation. At the distance 225 cm from PD source, Vpp of PD is equal to Vpp of the background noise (BGN). Therefore, the maximum distance of the loop sensor to PD source is 225 cm.
Measurement of Partial Discharge Inside Metal Enclosed Power Apparatus using Internal Sensor Khayam, Umar; Yushan, Yushan
Proceeding of the Electrical Engineering Computer Science and Informatics Vol 4: EECSI 2017
Publisher : IAES Indonesia Section

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (394.012 KB) | DOI: 10.11591/eecsi.v4.1065

Abstract

Partial discharge detection by detecting the released energy in form of electromagnetic wave during discharge using Ultra-High Frequency (UHF) antenna is one method to determine insulation system quality in high voltage system. UHF PD detection method has several advantages over conventional PD detection system such as IEC 60270 method. The advantages of UHF PD detection system are the capability to directly detect PD signal without firstly shut down, the installation system and their immunity from environmental noise. Nowadays most of electrical equipment are in form of metal enclosed model. This paper deals with measurement of PD occurrences inside metal enclosed equipment using internal sensor. The loop antenna is used for PD measurement. The experimental results show that the presence of metal box gives significant change on the PD signal detected by using loop antenna. Without metal box, the measurement sensitivity decreases because of the high level of background noise. The metal box acts as electromagnetic wave shielding and reduces the external noise. When the loop antenna placed inside metal box, the measurement sensitivity increases because of the low level of background noise inside metal box.
Pengaruh Keberadaan Partikel Asing Terhadap Karakteristik Medan Listrik Pada GIS Equilateral Tiga Fasa Pratama, Rizki Wahyu; Andre, Hanalde; Khayam, Umar
JURNAL NASIONAL TEKNIK ELEKTRO Vol 10, No 1: March 2021
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (7057.822 KB) | DOI: 10.25077/jnte.v10n1.850.2021

Abstract

This paper analyzes the effect of the presence of foreign particles on an equilateral arrangement of 3 phase gas insulated switchgear (GIS) insulation equipment. In this calculation, the electric field characteristics will be analyzed in 3-phase equilateral GIS by varying the location of the particles in the GIS tank. Particles are modeled to have a length of 5 mm and a thickness of 0.5 mm located in a 3 phase GIS equilateral arrangement with a tank diameter of 150 mm and a conductor diameter of 25 mm. The electric field calculations are reviewed at several points in the 3-phase equilateral GIS tank. The simulation and calculation of the electric field were calculated with FEM method software. The results of the calculations show that there are differences in the characteristics of the electric field between normal GIS and GIS where foreign particles are present. The difference in these characteristics can be seen in the magnitude of the electric field, and the ratio of eccentricity from some point of view. Keywords : gas insulated switchgear, equilateral, foreign particles, electric field, eccentricity ratioAbstrakPaper ini menganalisa tentang pengaruh keberadaan partikel asing pada peralatan hubung isolasi gas/ gas insulated switchgear (GIS) 3 fasa susunan equilateral. Pada perhitungan ini, akan dianalisa karakteristik medan listrik pada GIS equilateral 3 fasa dengan memvariasikan letak partikel dalam tangki GIS. Partikel dimodelkan memiliki panjang 5 mm dan ketipisan 0.5 mm terletak di dalam GIS 3 fasa susunan equilateral dengan diameter tangki 150 mm dan diameter konduktor 25 mm. Perhitungan medan listrik ditinjau pada beberapa titik dalam tangki GIS equilateral 3 fasa. Simulasi dan perhitungan medan listrik dilakukan dengan perangkat lunak menggunakan metode FEM. Hasil dari perhitungan menunjukkan adanya perbedaaan karakteristik medan listrik antara GIS normal dengan GIS yang terdapat partikel asing. Perbedaan karakteristik ini dapat dilihat pada besar medan listrik, dan rasio eksentrisitas pada beberapa titik tinjau keberadaan partikel. Kata Kunci : gas insulated switchgear,  equilateral, partikel asing, medan listrik, rasio eksentrisitas