Load characteristic analysis of a double-side internal coreless stator axial flux PMG Wirtayasa, Ketut; Irasari, Pudji; Kasim, Muhammad; Widiyanto, Puji; Hikmawan, Muhammad Fathul
Journal of Mechatronics, Electrical Power and Vehicular Technology Vol 10, No 1 (2019)
Publisher : Research Centre for Electrical Power and Mechatronics, Indonesian Istitutes of Sciences

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2867.192 KB) | DOI: 10.14203/j.mev.2019.v10.17-23

Abstract

The main issue of using a permanent magnet in electric machines is the presence of cogging torque. Several methods have been introduced to eliminate it, one of which is by employing a coreless stator. In this paper, the load characteristic analysis of the double-side internal coreless stator axial flux permanent magnet generator with the specification of 1 kW, 220 V, 50 Hz, 300 rpm and 1 phase is discussed. The purpose is to learn the effect of the load to the generator performance, particularly the output power, efficiency and voltage regulation. The design and analysis are conducted analytically and numerically with two types of simulated loads, pure resistive and resistive-inductive in series. Each type of load provides power factor 1 and 0.85 respectively. The simulation results show that when loaded with resistive load, the generator gives a better performance at the output power (1,241 W) and efficiency (91 %), whereas a better voltage regulator (5.86 %) is achieved when it is loaded with impedance. Since the difference in the value of each parameter being compared is relatively small, it can be concluded that the generator represents good performance in both loads.
Torque Characteristic Analysis of Outer Rotor Permanent Magnet Generator for Low Head Hydro Power Application Irasari, Pudji; Hikmawan, Muhammad Fathul; Widiyanto, Puji
Jurnal IPTEK Vol 23, No 2 (2019)
Publisher : LPPM Institut Teknologi Adhi Tama Surabaya (ITATS)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31284/j.iptek.2019.v23i2.524

Abstract

This paper analyzes the torque characteristics of outer rotor PMG for low head hydro power application. The aim is to prevent the generator torque from exceeding the turbine torque as the prime mover so that the system can work properly in both start and steady state conditions. The PMG is of outer rotor type and the torques are calculated analytically and numerically. The analysis is focused only on the PMG without connecting it to the turbine. Two analyzed torques include electromagnetic torque and starting torque, which comprises cogging torque, hysteresis torque and friction torque. The electromagnetic torque was obtained by loading the PMG with resistance and impedance (RL-LL in series) respectively. The results indicate that electromagnetic torque is the highest among all the investigated torques although its value is only 5.6% of the turbine torque, and cogging torque is the highest among the starting torque. From those results, it can be concluded that the hydro turbine torque can overcome the generator torque both at start and steady state conditions.