Analisis Distribusi Medan Listrik pada Isolator Gantung Jenis Polimer akibat Pengaruh Kontaminan Fahmi, Daniar; Yulistya, I Made; Asfani, Dimas Anton; Afif, Yusrizal
JURNAL NASIONAL TEKNIK ELEKTRO Vol 4, No 2: September 2015
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (896.631 KB) | DOI: 10.25077/jnte.v4n2.158.2015

Abstract

The paper investigates the electric field distribution in polymer suspension insulator when exposed to contaminants. The analyzed suspension insulator has glass core and will be simulated using FEM (Finite Element Method) software. Contaminant used is sea water. Simulations carried out by comparing the condition of the electric field on the surface of the insulator which is contaminated by seawater with normal conditions. In addition, the influence of the contact angle on the characteristics of the electric field distribution in insulators will also be analyzed. Therefore, the shape of contaminants are varied by considering the contact angle Then, to determine the deeper influence of contaminant, the analysis is carried out in three different places, which is the core part, the surface of the insulator and the fin closest to the working voltage insulator. From the conducted analysis, it is known that the contaminants are not much affected the electric field distribution at the core, but became very influential in the distribution of the electric field at the surface of the insulator and the fin closest to the working voltage insulator. Furthermore, the contact angle of contaminants affects the characteristics of the distribution of the electric field significantlyKeywords : Glass Core Rod, Polymer Suspension Insulator, Sea Water Contaminant, Contact Angle Abstrak—Paper ini menyelidiki distribusi medan listrik pada isolator gantung berbahan polimer ketika isolator tersebut terkena kontaminan. Isolator gantung yang dianalisis mempunyai inti gelas dan akan disimulasikan menggunakan perangkat lunak berbasis FEM (Finite Element Method). Kontaminan yang digunakan adalah air laut. Simulasi dilakukan dengan membandingkan kondisi medan listrik pada permukaan isolator yang terkontaminasi air laut dengan kondisi normal. Selain itu, juga akan dianalisis pengaruh sudut kontak terhadap karakteristik distribusi medan listrik di isolator. Oleh karena itu, bentuk kontaminan divariasikan dengan mempertimbangkan sudut kontak Kemudian, untuk mengetahui pengaruh lebih dalam, analisis dilakukan di tiga tempat yang berbeda, yaitu pada bagian inti, permukaan isolator dan sirip terdekat dengan tegangan kerja isolator. Dari analisis yang dilakukan, diketahui bahwa kontaminan yang menempel tidak banyak mempengaruhi persebaran medan listrik pada bagian inti, namun menjadi sangat berpengaruh pada persebaran medan listrik di permukaan isolator dan sirip terdekat dengan tegangan kerja isolator. Lebih jauh lagi, sudut kontak dari kontaminan mempengaruhi besar dan karakteristik dari persebaran medan listrik secara signifikan.Kata Kunci : Batang Inti Bahan Gelas, Isolator Gantung Polimer, Kontaminan Air Laut, Sudut Kontak
Sistem Monitoring Charging Station Mobil Listrik berbasis Embedded Web Server Suwito, Suwito; Asfani, Dimas Anton; P, Gilang Dwi
JAVA Journal of Electrical and Electronics Engineering Vol 13, No 2 (2015)
Publisher : JAVA Journal of Electrical and Electronics Engineering

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (753.884 KB)

Abstract

Charging station merupakan tempat pengisian energi listrik bagi kendaraan listrik. Sistem charging station yang dimaksud disini dapat berupa Hybrid Power Generation, yang sumber energinya dari listrik jala-jala dan Photovoltaic (PV). Terdapat beberapa proses pengkondisian tegangan dan arus dari sumber menuju bus DC seperti Inverter, MPPT dan DC/DC converter. Dengan prinsip hall effect, sensor tegangan LV 25-P dan sensor arus LA 55-P digunakan untuk mengambil data tegangan dan arus di titik yang perlu di monitoring pada charging station. Sistem monitoring di desain menggunakan mikrokontroller arduino uno sebagai analog digital converter, ethernet shield sebagai modul ethernet untuk transmisi data, dan komputer sebagai database server. Data dari sistem monitoring ini dapat dilihat dan diakses dalam bentuk halaman web dengan mode real time dan data logger. Untuk data logger disajikan dalam bentuk tabel dan grafik 1000 data terakhir, dimana pengiriman data dari mikrokontroller terjadi setiap 10 detik. Hasil akuisisi data memiliki ketilitian 0.72% pada nilai tegangan 259.8 V DC dan 1.09% pada nilai arus 12.9 A DC. Pengukuran tersebut dilakukan pada keadaan yang sengaja dikondisikan dengan skala laboratorium.
Analisis Pengaruh Semen Konduktif Sebagai Media Pembumian Elektroda Batang Negara, I Made Yulistya; Fahmi, Daniar; Asfani, Dimas Anton; Prajanuarto, Bimo; M, Arief
JAVA Journal of Electrical and Electronics Engineering Vol 12, No 2 (2014)
Publisher : JAVA Journal of Electrical and Electronics Engineering

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (448.575 KB)

Abstract

Pada studi ini dilakukan metode pembumian dengan elektroda batang serta kombinasi peletakan semen konduktif untuk mengetahui penurunan resistansi pembumian sebelum dan setelah pemberian semen konduktif disekitar elektroda batang. Pada studi ini hasil pengujian secara langsung yang telah diperoleh digunakan sebagai acuan awal untuk dilakukan tinjauan selanjutnya. Studi ini dilakukan agar pembumian dapat dilakukan pada tanah yang tidak dapat digali dengan kedalaman yang cukup sehingga pemberian semen konduktif ini memungkinkan untuk dilakukannya pembumian yang baik. Pengkodisian tanah yang dilakukan pada studi ini yaitu dengan menggunakan elektroda batang (rod) yang ditanam kedalam tanah dengan kedalaman tetap, yang sebelumnya tanah telah di treatment dengan dengan mencampurkan semen konduktif pada tanah sebagai medium penurun resistansi tanah dengan volume dan posisi yang berbeda. Untuk mengetahui parameter tahanan yang akan diukur memakai alat earth resistance tester. Pengujian ini dilakukan berulang kali untuk mengetahui nilai rata – rata yang ditentukan analisa data dengan pengujian serta perhitungan matematik. Dari analisis telah diperoleh bahwa posisi peletakan semen konduktif mempengaruhi penurunan resistansi pembumian. Selain itu, pengaruh kerapatan material yang terkandung dalam tanah juga mempengaruhi penurunan resistansi pembumian.
Characteristic Analysis Of Arc Flash In Low Voltage Electrical Power Caused By The Effect Of Short Circuit Impedance Asfani, Dimas Anton; Negara, I Made Yulistya; Fahmi, Daniar; Hernanda, I.G.N Satriyadi; Irmawati, Novia Ayu
JAVA Journal of Electrical and Electronics Engineering Vol 14, No 1 (2016)
Publisher : JAVA Journal of Electrical and Electronics Engineering

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (772.147 KB)

Abstract

Fire cases caused by an electrical short circuit (arc flash) at low voltage are still very high in Indonesia recently. Several studies about characteristic analysis of arc flash at low voltage has been done. In this study, an experiments of arc flash phenomena at low voltages using an artificial short-circuit device is conducted.  The arc flash’s experiment is applied to low voltage stranded conductor cable 1.5mm2 (24 filaments) with resistive load using some objects as short-circuit media (metallic objects, non-metallic objects, and solution).  Low voltage arc flash characteristics such as maximum current, maximum power, duration and energy of each short circuit media to be analyzed. The results of this study is expected to design protective device (detector) that can be detected low voltage arc flash in future research
Sensitive Detection for High Impedance Fault on Transmission Line using Wavelet and Naive Bayes Asfani, Dimas Anton; Negara, I Made Yulistya; Rajavalens, Muhammad
JAVA Journal of Electrical and Electronics Engineering Vol 12, No 2 (2014)
Publisher : JAVA Journal of Electrical and Electronics Engineering

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (233.821 KB)

Abstract

This paper presents the combination method of wavelet transform and naive bayes classifier to detect and classify the high impedance fault of transmision line. The fault’s current signal is transformed using wavelet. The transformed signal produces coefficients with certain pattern according to the type of fault that occurs. Then, coefficients of transformed signal arevariated become 7 variabels, based on the algorithm of classification. Those variabels are classified using naive bayes classifier to detect and classify the fault of transmission line. Three types of mother wavelet used in this study are Daubechies- 5 (Db5), Daubechies-8 (Db8), and Coiflet-5 (Coif5). Every mother wavelet produces different coefficients. However, they have similar pattern to the algorithm of classification. The highest accuracy of classification was obtained using coeffisients of Daubechies-5 (Db5) at 5th level. The classification accuracy is 97.09% using normal distribution, and 99.78% using kernel distribution.
Analisis Persebaran Medan Listrik pada Quadruple Spacer Saluran Transmisi 500 kV akibat Pengaruh Polusi Udara Fahmi, Daniar; Negara, I Made Yulistya; Asfani, Dimas Anton
JAVA Journal of Electrical and Electronics Engineering Vol 10, No 2 (2012)
Publisher : JAVA Journal of Electrical and Electronics Engineering

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (169.498 KB)

Abstract

Pada studi ini dilakukan analisa medan listrik pada quadruple spacer yang digunakan pada transmisi 500 kv dengan menggunakan simulasi berbasis FEM (Finite Element Method) serta membandingkan medan listrik pada kondisi normal dengan kondisi berpolutan dan untuk mengetahui perbandingan medan listrik dengan kadar dan jenis yang berbeda. Polutan yang digunakan adalah polutan air garam (NaCl) dan debu (CaCO3) yang ditempatkan dengan menempelkannya pada kabel konduktor pada simulasi. Dari Studi ini diperoleh bahwa polutan mempengaruhi perubahan medan listrik pada spacer. Jenis polutan juga mempengaruhi besar kecilnya perubahan dimana polutan air garam (NaCl) memiliki nilai medan listrik yang lebih besar daripada polutan debu (CaCO3)
Testing and Simulation of Motor Insulation System under Some Artificial Environmental Conditions Yulistya Negara, I Made; Anton Asfani, Dimas; Sudatul Aisyah N, Siti
Proceeding of the Electrical Engineering Computer Science and Informatics Vol 1: EECSI 2014
Publisher : IAES Indonesia Section

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (985.386 KB) | DOI: 10.11591/eecsi.v1.343

Abstract

This study deals with the effect of humidity and contamination of salt on insulation resistance and polarization index. It investigated experimentally and is also analyzed by using its equivalent circuit. Surface leakage and absorption currents were measured to interpret the quality of insulation winding of a motor. The result shows that in all conditions, the value of absorption current is constant during the testing, meanwhile due to effect of humidity and contamination the leakage current is much larger than normal conditioned motor. Data obtained from insulation resistance test are used to calculate the resistance to ground (RTG) and capacitance to ground (CTG). RTG and CTG are then used as value of components on equivalent circuit for simulation matter. The simulation result using equivalent circuit is reasonable agree with the experiment done.
Designing and performance investigation of permanent magnet motor prototype for UTV electric drive train application Muhammad Nur Yuniarto; Yoga Uta Nugraha; I Made Yulistya Negara; Dimas Anton Asfani; Indra Sidharta
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 12, No 4: December 2021
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijpeds.v12.i4.pp2018-2029

Abstract

The dynamic design specifications of a vehicle are used to define the required torque and speed of a permanent magnet motor. This is due to providing clear instructions on the intent, performance, and construction of a vehicle. Therefore, this study aims to determine an engineering design and prototyping process of a Permanent Magnet Motor, to be used as an electric powertrain in a Utility Vehicle. Based on being used in severe road condition (steep inclination and off road), the vehicle should be able to handle a 45° inclination with total payload of approximately 250 kg. Using a rear-wheel-drive traction, its weight should also be less than 1000 kg. Furthermore, the motor should be operated at a maximum battery voltage of 100 V. According to the requirements, the electric powertrain should further have the ability to deliver a torque of approximately 1600 Nm on both rear wheels. Using a finite element method to simulate performances, transmission was coupled to the motor in providing the required torque. In addition, the motor prototype was subsequently manufactured and tested using a dynamometer. The results showed that the motor produced 19.6 kW, 5600 RPM, and 75 Nm at 96 V. Therefore, the design and prototyping process of the motor satisfied all the required specification.
Desain Peralatan Pendeteksi Gangguan Hubung Singkat Belitan Stator Motor Induksi Menggunakan Arus Online Berbasis Mikrokontroler Ade Kurniawan Putra; Dimas Anton Asfani; Dedet Candra Riawan
Jurnal Teknik ITS Vol 4, No 2 (2015)
Publisher : Direktorat Riset dan Pengabdian Masyarakat (DRPM), ITS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (666.59 KB) | DOI: 10.12962/j23373539.v4i2.9802

Abstract

Motor induksi adalah salah satu peralatan utama dalam industri. Kerusakan pada bagian motor akan mempengaruhi proses dan hasil produksi. Oleh karena itu, deteksi dini kerusakan motor induksi sangat dibutuhkan untuk menghindari kerusakan yang lebih parah. Pada tugas akhir ini akan didesain sistem monitoring untuk menganalisa dan mendeteksi kerusakan pada motor berdasarkan pembacaan arus fasa dan tegangan fasa belitan motor induksi pada saat keadaan normal maupun gangguan melalui komputer. Pada layar komputer akan ditampilkan hasil pembacaan tegangan dan arus. Dari parameter tersebut dapat dilakukan diagnosa keadaan dari motor induksi apakah dalam keadaan normal atau tidak. Bila terjadi gangguan pada motor induksi, sistem ini dapat mendeteksi jenis gangguan yang terjadi pada motor induksi tersebut.   Kata Kunci : belitan stator, hubung singkat, motor induksi  
Deteksi Gangguan pada Saluran Transmisi menggunakan Wavelet dan Discriminant Analysis Febrianto Wahyu Utomo; I Gusti Ngurah Satriyadi Hernanda; Dimas Anton Asfani
Jurnal Teknik ITS Vol 2, No 2 (2013)
Publisher : Direktorat Riset dan Pengabdian Masyarakat (DRPM), ITS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (230.795 KB) | DOI: 10.12962/j23373539.v2i2.3402

Abstract

Sistem transmisi merupakan bagian penghubung antara pusat pembangkit tenaga karena saluran listrik dengan sistem distribusi yang akan diteruskan ke pusat-pusat beban. Penetuan gangguan pada saluran transmisi sangat penting untuk mempercepat proses perbaikan. Jika terjadi hubung singkat dengan resistansi begitu besar akan mengakibatkan arus gangguan sama dengan arus nominal. Kondisi tersebut dapat mengakibatkan kerugian yang tak terdeteksi. Salah satu metode yang dapat digunakan dalam penentuan gangguan yaitu dengan menggunakan kombinasi transformasi wavelet dan discriminant analysis.Transformasi wavelet digunakan untuk mengolah sinyal gangguan (transient) yang akan menghasilkan variabel input yang mempunyai korelasi dengan jenis gangguan. Pola antara variabel input dan jenis gangguan ini akan diklasifikasikan oleh discriminant analysis menggunakan Linear Discriminant Analysis (LDA) dan Quadratic Discriminant Analysis (QDA) untuk sistem deteksi jenis gangguan pada saluran transmisi. Variabel input dari ketiga mother wavelet memiliki nilai yang berbeda pada setiap kondisi gangguan yang sama namun tidak jauh berbeda untuk nilai tiap levelnya. Berdasarlan Hasil Simulasi dengan menggunakan LDA, mother wavelet terbaik dalam mengenali pola jenis gangguan pada saluran transmisi adalah wavelet haar level kelima sedangkan ketika menggunakan QDA, mother wavelet terbaik adalah wavelet discrete meyer pada level kelima. Dimana wavelet tersebut memiliki error paling kecil dibandingkan mother wavelet yang lain.