Analysis of the Effect of Loading on the Transformers Usage Time Ritonga, Adi Syahputra; Muthalib, Muchlis Abdul; Daud, Muhammad; Lubis, Hamdi Akmal; Pokhrel, Biswas Babu; Phuyal, Sudip; Gohatre, Umakant B.
Journal of Renewable Energy, Electrical, and Computer Engineering Vol 1, No 2 (2021): September 2021
Publisher : Institute for Research and Community Service, Universitas Malikussaleh, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/jreece.v1i2.5237

Abstract

The reliability and stability of the system in the operation of the electric power system is very important, in order to provide comfort in service to consumers. The transformer is a very important component in the electric power system, because it is used as a voltage adjuster for the load being served. This study discusses the effect of loading and temperature on the life shrinkage of 36/60 MVA power transformers in block 3 and block 4 carried out at PT. PJB UBJ O&M PLTMG Arun Lhokseumawe, Aceh. From the calculation results after 4 years the transformer operates, if the transformer is given a 100% load, the transformer will experience an age difference of 2.52 p.u/day so that it has a remaining life for of 10 years. As for the transformer that is given a load of 90%, the transformer will experience an age difference of 1.44 p.u/day so that it has a remaining life to perform operations for another 18 years. Then for a transformer that is given a load of 80%, the transformer will experience an age difference of 0.67 p.u/day so that it will have a remaining life to carry out the operation again for another 38 years. From the above calculation, the origin of the temperature obtained for the ONAN type of cooler in block 3 is 0.71 p.u/day and in block 4 it is 0.70 p.u/day. While the ONAF type of cooler in block 3 is 0.004 p.u/day and in block 4 it is 0.005 p.u/day. This is in accordance with the regulation SPLN50/1982 regarding transformer life shrinkage.
Voltage Profile Improvement of Distribution System via Integration of Distributed Generation Resources Pokhrel, Biswas Babu; Shrestha, Ashish; Phuyal, Sudip; Jha, Shailendra Kumar
Journal of Renewable Energy, Electrical, and Computer Engineering Vol 1, No 1 (2021): March 2021
Publisher : Institute for Research and Community Service, Universitas Malikussaleh, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/jreece.v1i1.3519

Abstract

This study attempts to identify the causes and possible solutions for voltage profile issues in the lower land of Nepal, and is specifically focused on Laukahi feeder, a radial distribution system with an approximate length of 65 km and distributed at 11KV system voltage. Currently, the end-users feeding through this feeder are getting extremely poor voltage along with frequent interruptions in the power supply. In this study, a forward/ backward sweep algorithm is used to analyze the load flow of the distribution system, whereas ant colony optimization (ACO) technique is used to identify the best location for the Distributed Generator (DG) penetrations. After completion of this study, it is found that, the branch loss of the feeder can be reduced up to 87.22%, and voltage profile can be improved from 0.828 pu to 0.982 pu by integrating some form of DGs.