R. Abd. Rahman
Universiti Tun Hussein Onn Malaysia

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

The effect of short circuit fault on one winding to other windings in FRA N. F. M. Yasid; M. F. M. Yousof; R. Abd. Rahman; H. Zainuddin; S. A. Ghani
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 10, No 2: June 2019
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (396.17 KB) | DOI: 10.11591/ijpeds.v10.i2.pp585-593

Abstract

Monitoring and diagnosis of power transformer in power systems have been examined and debated significantly in last few decades. Recently, more researchers have expressed their interest in these issues as the utilities and network operators operating under a rising cost-effecting pressure. Especially, in studying to monitor winding faults which is found to be the most common fault within transformers. This paper addresses the issue of the effect of inter-windings short circuit fault in a Dyn11 connected transformer. The specific aim is to study the effect of fault at winding of other phases to the response of measured phase. Frequency Response Analysis (FRA) which is discovered to be a powerful and sensitive method to examine and evaluate the condition, including the mechanical reliability of the transformer windings is used.
Conductor sag comparison for 132 kV overhead transmission line improvement in Malaysia H. M. Luqman; M. N. R. Baharom; N. A. M. Jamail; N. A. Othman; R. Abd. Rahman; M. F. M. Yousof; Irshad Ullah
Bulletin of Electrical Engineering and Informatics Vol 9, No 1: February 2020
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (517.533 KB) | DOI: 10.11591/eei.v9i1.1863

Abstract

This paper presents conductor sag comparison for 132 kV overhead transmission line improvement in Malaysia. Increasing industrialization and population growth around the world demands higher electricity supply. Power generation has yet to decline but transmitting sufficient electricity to consumers is worrisome due to scarce land space occupied by rapid urbanization. Hence reconductoring method was chosen to improve existing 132 kV overhead transmission line in Malaysia. A group of selected conductors were chosen for comparison where the high temperature low sag conductor stood out the most producing up to 40% sag reduction. This paper focuses on providing conductor alternatives to improve maximum sag of lowest conductor to ground for 132 kV transmission line in Malaysia in accordance to her climate and geographical factor.