Claim Missing Document
Check
Articles

Found 2 Documents
Search

The effect of short circuit fault on one winding to other windings in FRA N. F. M. Yasid; M. F. M. Yousof; R. Abd. Rahman; H. Zainuddin; S. A. Ghani
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 10, No 2: June 2019
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (396.17 KB) | DOI: 10.11591/ijpeds.v10.i2.pp585-593

Abstract

Monitoring and diagnosis of power transformer in power systems have been examined and debated significantly in last few decades. Recently, more researchers have expressed their interest in these issues as the utilities and network operators operating under a rising cost-effecting pressure. Especially, in studying to monitor winding faults which is found to be the most common fault within transformers. This paper addresses the issue of the effect of inter-windings short circuit fault in a Dyn11 connected transformer. The specific aim is to study the effect of fault at winding of other phases to the response of measured phase. Frequency Response Analysis (FRA) which is discovered to be a powerful and sensitive method to examine and evaluate the condition, including the mechanical reliability of the transformer windings is used.
AC breakdown behavior of SF6/N2 gas mixtures under non-uniform field electrode configurations N. F. Ambo; H. Zainuddin; M. S. Kamarudin; J. M. Wari; A. Zahari
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 17, No 5: October 2019
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v17i5.12806

Abstract

Sulphur hexafluoride (SF6) gas owns remarkable properties as insulation medium and current interrupter, which make it being widely used in gas-insulated equipment up to now. However, SF6 gas has a drawback that gives adverse effect to the environment since it is a strong greenhouse gas. As the effort to minimize the SF6 usage, this study was conducted to investigate the AC breakdown behavior of SF6/N2 gas mixtures with 10/90 ratio at low pressure levels (i.e. 0.11 MPa to 0.15 MPa) under non uniform field (i.e. R0.5-plane and R6-plane electrodes configurations). The results of the study indicate that the breakdown voltage of SF6/N2 gas mixtures in non-uniform field increases linearly with the increase of gas pressure and electrodes gap distance. As a function of gap distance, a higher increasing rate of breakdown voltage values were achieved at lowest pressure of 0.11 MPa compared to other pressure levels. In addition, it is also found that a higher breakdown voltage values was obtained under R6-plane configuration. But, the difference in breakdown voltage values between R0.5-plane and R6-plane configuration is less significant as the gap distance is increased. It is also observed that the field efficiency factor of R6-plane is higher than R0.5-plane which indicates a more uniform field exists between the electrodes.