Faults Diagnosis in Five-Level Three-Phase Shunt Active Power Filter L. Benyettou; T. Benslimane; O. Abdelkhalek; T. Abdelkrim; K. Bentata
International Journal of Power Electronics and Drive Systems (IJPEDS) Vol 6, No 3: September 2015
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (828.79 KB) | DOI: 10.11591/ijpeds.v6.i3.pp576-585

Abstract

In this paper, characteristics of open transistor faults in cascaded H-bridge five-level three-phase PWM controlled shunt active power filter are determined. Phase currents can’t be trusted as fault indicator since their waveforms are slightly changed in the presence of open transistor fault. The proposed method uses H bridges output voltages to determine the faulty phase, the faulty bridge and more precisely, the open fault transistor.