Influencing Power Flow and Transient Stability by Static Synchronous Series Compensator Md. Imran Azim; Md. Abdul Wahed; Md. Ahsanul Haque Chowdhury
Indonesian Journal of Electrical Engineering and Informatics (IJEEI) Vol 3, No 2: June 2015
Publisher : IAES Indonesian Section

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.52549/ijeei.v3i2.144

Abstract

In the present world, modern power system networks, being a complicated combination of generators, transmission lines, transformers, circuit breakers and other devices, are more vulnerable to various types of faults causing stability problems. Among these faults, transient fault is believed to be a major disturbance as it causes large damage to a sound system within a certain period of time. Therefore, the protection against transient faults, better known as transient stability control is one of the major considerations for the power system engineers. This paper presents the control approach in the transmission line during transient faults by means of Static Synchronous Series Compensator (SSSC) in order to stabilize Single Machine Infinite Bus (SMIB) system.  In this paper, SSSC is represented by variable voltage injection associated with the transformer leakage reactance and the voltage source. The comparative results depict that the swing curve of a system increases monotonically after the occurrence of transient faults However, SSSC is effective enough to make it stable after a while.
Harmonic Analysis of a Single Phase Modulated Inverter Md. Imran Azim; S. M. Mohiuddin
Indonesian Journal of Electrical Engineering and Computer Science Vol 2, No 3: June 2016
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijeecs.v2.i3.pp607-616

Abstract

This paper portrays an approach of an analysis that provides information regarding the presence of harmonics at the inverter output terminal. It is certainly true that harmonics cause unbalance and excessive neutral currents, interference in nearby communication networks and disturbance to other consumers. More importantly, torque pulsations in electric motor drives are caused by them. Thus, the minimization of the harmonics contained in the output of a single phase current controlled inverter undergoing hysteresis modulation technique is important so as to get rid of these detrimental effects. A model of an LC low pass filter has been provided in this paper for harmonics reduction purpose, as it blocks the harmonics and passes approximately a sinusoidal output. Moreover, the paper contains the method of Fast Fourier Transform (FFT) for fulfilling the desire of understanding not only the fundamental component but also the harmonics component flawlessly. It has been found from the simulation that the Total Harmonic Distortion (THD) in ideal case is 0%. On the other contrary, during the presence of harmonics, it steeps to 41.415% that can be mitigated to 0.0092% by implementing an LC low pass filter in a precise manner.