Claim Missing Document
Check
Articles

Found 6 Documents
Search

Analisis Performa Turbin Angin Savonius Tipe U dengan Memvariasikan Jumlah Sudu Turbin Iwan Setyawan; Lutfi Laili Salim; Sri Poernomo Sari; Ridwan Ridwan
Jurnal Penelitian Enjiniring Vol 24 No 2 (2020)
Publisher : Center of Techonolgy (COT), Fakultas Teknik, Universitas Hasanuddin

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25042/jpe.112020.07

Abstract

Abstract Wind turbines are the main media that can be used to convert wind energy into electrical energy. The design of a good wind turbine determines the performance of a Wind Power Plant. The Savonius turbine on the vertical axis is an alternative for generating electrical energy because the development of the Savonius Turbine is directed at making economical ones, such as being able to operate at low wind speeds. This study aims to determine the performance of the Savonius turbine that has been made, the resulting generator power, and the efficiency of the generator used. The research was carried out using experimental methods by varying the number of blades 2,3 and 4. Testing was carried out directly in the coastal areas. The results were obtained from data processing are the largest turbine output power on the 2 blade turbine = 38.88 watts. The largest coefficient of power, the 2 blade turbine = 0.235. While the largest output power generated by the generator = 34.3 watts at the 4-blade turbine. The biggest generator efficiency is 12.02% on the 4 blade turbine.
Analisis Perancangan Tempat Pengolahan Limbah Masker Medis dengan Mengimplementasi Antropometri dan Ergonomic Function Deployment Yahya Zulkarnain; Ridwan Ridwan
JTI: Jurnal Teknik Industri Vol 8, No 2 (2022): DESEMBER 2022
Publisher : Universitas Islam Negeri Sultan Syarif Kasim Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24014/jti.v8i2.20038

Abstract

Awal tahun 2020 muncul virus baru yang menjadi ancaman bagi seluruh negara di dunia yaitu virus covid-19. Indonesia merupakan salah satu negara yang juga terdampak. Akibatnya, pemerintah Indonesia membatasi aktivitas dan mengurangi interaksi secara langsung. Pada Juli 2020, jumlah kasus penderita covid-19 di Indonesia mencapai 106.336 orang. Hal ini dikarenakan penularan virus tersebut sangat cepat. Penularan virus ini mendorong pemerintah Indonesia untuk menerapkan aktivitas baru yang biasa disebut protokol kesehatan, yaitu mencuci tangan, menjaga jarak dan menggunakan masker. Masker merupakan kebutuhan utama saat pandemi berlangsung, khususnya masker medis. Oleh karena itu penggunaan masker medis terus meningkat dan menyebabkan limbah masker medis terus meningkat pula. Hal tersebut mendorong penelitian ini tercipta, untuk dapat menurunkan tingkat limbah masker medis dengan melakukan perancangan tempat pengolahan limbah masker medis. Metode yang digunakan adalah Ergonomic Function Deployment dengan mengimplementasikan Antropometri dalam pengukurannya. Penelitian ini menggunakan 4 dimensi ukur, yaitu tinggi siku sebesar 124,40 cm, tinggi popliteal sebesar 25,78 cm, Panjang rentang tangan sebesar 79,5 cm dan rentang siku sebesar 73,67. Penyebaran kuesioner disebar kepada responden menghasilkan 14 poin kebutuhan pengguna yang dikategorikan menjadi 4 kategori, yaitu efektif, nyaman, aman, sehat dan efisien.
CFD Simulation With Ansys Effect Of Twisted Tape Ratio On Nusselt Number and Reynold Number Solar Collector singgah khairun okba; Ridwan Ridwan; Iwan Setyawan
Eksergi Vol 18, No 3 (2022): SEPTEMBER 2022
Publisher : Politeknik Negeri Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32497/eksergi.v18i3.3855

Abstract

Solar collector is one of the tools used to harness solar power and then convert it into heat which is used to heat water. The solar collector used is a flat plate type solar collector, the drawback of this solar collector is its low efficiency value. One method that can be used to increase its efficiency is to add twisted tape. Twisted tape serves to increase the value of the nusselt number and reynold number, where the increasing nusselt number and reynold number means the efficiency will increase, the Twisted Tape Ratio is the ratio between the distance of two peaks (H) and the width of the pipe (D). In this study using three variations of the tape ratio, namely 5,4, and 3, at Y = 5 the highest nusselt value and the Reynold number 4000 and Nuselt Number 24 were used, this is because the Twisted Tape ratio is 4 and 3 forms of twisted tape inhibit the flow. which causes a decrease in the value of the nusselt number and reynold number.
PID Controller Simulation on Single Axis Solar Tracking System MUHAMMAD FAIZ SIGIT; RIDWAN RIDWAN; SRI POERNOMO SARI
Jurnal Elkomika Vol 11, No 1 (2023): ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektr
Publisher : Institut Teknologi Nasional, Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26760/elkomika.v11i1.58

Abstract

ABSTRAKEfisiensi yang rendah pada solar cell dipengaruhi oleh beberapa factor yaitu tingkat radiasi, suhu, dan sudut instalasi. Penelitian ini membahas upaya meningkatkan performa solar panel yaitu dengan menggunakan sistem pelacak surya sumbu tunggal. Dalam penelitian sistem pelacak surya sumbu tunggal ini dimodelkan dengan menggunakan PID controller pada software Matlab Simulink. Dalam metode tracking system, solar cell disimulasikan pada sumbu tunggal yang berorientasi pada sudut elevasi, sebagai masukan dan pengoptimasian kontrol posisi yang tepat terhadap arah pergerakan matahari pada pukul 07.00 – 17.00 wib. Hasil simulasi didapatkan penggunan kontrol PID pada perancangan single axis solar tracking system menunjukkan hasil yang baik, dimana kontroler yang dirancang dapat mendeteksi arah pergerakan matahari dengan cukup akurat. Sudut elevasi terendah yaitu 1,7 derajat dan tertinggi 68,21 derajat. Solar tracking system memiliki potensi menyerap lebih banyak radiasi matahari untuk mendapatkan output lebih baik yang dihasilkan dari solar cell.Kata kunci: solar cell, sumbu tunggal, tracking system, PID controller, Simulink Matlab ABSTRACTThe low efficiency of the solar cell is influenced by several aspect, namely radiation levels, temperature, and tilt angle. This research discusses improving solar panels' performance using a single-axis tracking system. This research modelled a singleaxis of solar cell tracking system using a PID controller in Matlab Simulink software. In the tracking system method, the solar cell is simulated on a single axis oriented to elevation angle as input and optimization of precise position control to direct the sun's movement at 07.00 – 17.00 WIB. The simulation results shown that using a PID control in designing a single-axis of solar cell tracking system shows significant results, where the controller design can accurately detect the direction of the sun's movement. Furthermore, the lowest elevation angle is 1.7 degrees, and the highest is 68.21 degrees. Furthermore, solar tracking systems have the potential to absorb more radiation for a greater output of solar cells.Keywords: solar cells, single axis, tracking system, PID controller, Simulink Matlab
ANALISIS KINERJA TERMAL DARI STRAIGHT HEAT PIPE DENGAN SUMBU SCREEN MESH PADA SUDUT KEMIRINGAN YANG BERBEDA Iwan Setyawan; Riski Mekasyah Putra; Ridwan Ridwan; Tri Mulyanto
Jurnal Ilmiah Teknologi dan Rekayasa Vol 27, No 3 (2022)
Publisher : Universitas Gunadarma

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35760/tr.2022.v27i3.7561

Abstract

Heat pipe, HP adalah salah satu alat pemindah kalor yang bekerja secara pasif.  Dalam HP, tekanan kapiler dibuat di sumbu yang memompa cairan kondensat kembali ke bagian evaporator. Diantara parameter operasi yang mempengaruhi kinerja termal HP, adalah sudut kemiringan yang memiliki dampak yang cukup besar.  Pada penelitian ini akan menginvestigasi kinerja termal straight heat pipe dengan sudut kemiringan yang berbeda. Pengujian dilakukan pada straight heat pipe dengan panjang 1500 mm menggunakan screen mesh 300 material stainless steel 2 layar. Pengujian dilakukan dengan memvariasikan input beban kalor 10W, 25W, 50W, 100W, 175W, dan 275W    dengan sudut kemiringan 0o (posisi horizontal), sudut kemiringan 45o dan sudut kemiringan 90o (posisi vertikal). Pengambilan data temperatur diambil menggunakan data aquisition Labjack U6 Pro. Hasil penelitian menunjukkan bahwa dengan beban kalor 10 W ~ 275 W, heat pipe berhasil start-up pada semua sudut kemiringan.  Walaupun berhasil start-up, tetapi untuk beban kalor 10 W pada semua sudut kemiringan, temperature coolant-in berfluktuasi.  Ini mengindikasikan beban kalor 10 W belum cukup  untuk membangkitkan uap dengan tekanan yang memadai untuk mendorong uap ke kondensor.  Nilai tahanan termal, Rth terbesar terjadi pada posisi sudut kemiringan 45o sebesar 0,05, sedangkan sudut kemiringan 90o dan sudut kemiringan 0o mempunyai Rth yang relatife sama, yakni sekitar 0,02.  Namun demikian, heat pipe dengant sudut kemiringan 0o mempunyai temperatur evaporator yang lebih kecil dibandingkan sudut 90o. Jadi, dapat disimpukan bahwa heat pipe memiliki kinerja termal terbaik ketika sudut kemiringan 0o (posisi horizontal). Hasil ini pula menunjukkan bahwa heat pipe yang relatife besar dengan panjang 1500 mm, relatf terpenpengaruh oleh gaya grafitasi.  Dengan pengaruh grafitasi menyebabkan sudut kemiringan  90o (posisi vertikal) mempunyai kinerja yang lebih baik dibandingkan sudut kemiringan 45oC.
Pengaruh Massa dan Kecepatan Kendaraan Terhadap Suhu Pada Rem Drum Ridwan Ridwan; Afrizal Riyantono; Rudi Irawan
Jurnal Sinergi Jurusan Teknik Mesin Vol 21, No 2 (2023): Oktober 2023
Publisher : Politeknik Negeri Ujung Pandang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31963/sinergi.v21i2.4600

Abstract

Brakes are a tool for slowing down or stopping a vehicle while it's in motion. They also serve as a safety mechanism when a vehicle is parked or at a stop. Brakes can convert kinetic and potential energy into heat through the frictional process between brake pads and the rotor, leading to heat transfer. In the world of transportation, analyzing the heat generated by the vehicle's brakes is a crucial process for evaluating and enhancing braking system performance. In this study, simulations were conducted on the brake rotor (drum brake) of a minibus with vehicle masses of 3500 kg and 5000 kg, using Abaqus software. Five different speed variations were considered: 60 km/h, 70 km/h, 80 km/h, 90 km/h, and 100 km/h. The simulation results for the vehicle with a mass of 3500 kg showed progressively increasing maximum temperatures in the brake rotor: 87.82°C, 106.55°C, 163.69°C, 216.34°C, and 275.04°C for the respective speeds. In the simulation with a vehicle mass of 5000 kg, the maximum rotor temperatures were 108.45°C, 126.33°C, 207.9°C, 269.03°C, and 299.31°C. Higher braking speeds result in higher heat generation in the brake rotor. However, the temperature increase is not linear concerning vehicle speed. The vehicle's mass significantly influences the heat generated in the rotor during braking. At the same speed, a higher-mass vehicle will produce more heat.