This study was aimed at finding out the students’ perceptions of final report advisory services in English Department of State polytechnic of Sriwijaya. This would expectedly give insights on how well the tasks of providing services in terms of assisting students with their final report writing had been performed. Questionnaires were self-made, and therefore the validity and reliability test were conducted in which 19 students were involved. The results of this piloting project were analyzed by using the Pearson Product Moment Coefficient. To get the data, 77 students were requested to fill out the questionnaires. Through the use of statistic desriptive analysis, the data were processed and then described in words and numbers. The conclusion was that the lecturers of The English Department had performed their task porperly in providing final report advisory services to their students.
Automation of Load Electricity Operating System Using PLC (Programmable Logic Controller) Hairul; Fatahul Arifin; Romi Wilza; Zakaria Zakaria; Kurniawan; Yusuf Dewantoro Herlambang
International Journal of Research in Vocational Studies (IJRVOCAS) Vol. 3 No. 1 (2023): IJRVOCAS - April
Publisher : Yayasan Ghalih Pelopor Pendidikan (Ghalih Foundation)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53893/ijrvocas.v3i1.200

Abstract

Jakabaring PLTS on-grid with a capacity of 2 MW operates from 6:00 am to 5:00 pm. At 5:00 pm the PLTS connection to the load will be disconnected and replaced with PLN. If the PLN is off due to damage or during maintenance, a generator that is operated manually will be used. Problems in the process of combining energy sources from Solar Panels to PLN require a power target of up to 10 Kva where if the power is fulfilled then the energy source from Photovoltaic (PV) will be connected to PLN and vice versa. Errors and speed in operation can be minimized by means of automation of the system operating the power supply to the load by using a PLC (Programmable Logic Controller). Optimization as a step to optimize the electricity supply in the PLTS area makes it the first source of power generation that is connected to the load, the second order is PLN if the PLTS has no power output or there is a problem and the third order is generators if PLN and PLTS have no power output. For this reason, a tool is needed that functions to move the power source alternately using a PLC (Programmable Logic Controller) as an ATS (Automatic Transfer Switch) process controller, where the tool will work automatically changing the power source if there is a disturbance that causes it to be unable to supply electricity to the user's load and also as a priority regulator of solar power sources as the main source of electricity to the load. When transferring loads from one source to another with 3 different power sources, it is faster and more effective to use an ATS (Automatic Transfer Switch) with a PLC controller compared to Manual or COS (Change Over Switch).