IPAL EFEKTIVITAS BIOFILTER DALAM MEREDUKSI POLUTAN PADA AIR LIMBAH RUMAH SAKIT DI KOTA PALU Pitriani Pitriani; Mutmainnah Maulani; Trivena Tatulus; Farida Indriani; Kiki Sanjaya; Nurdin; Lusia Salmawati
Afiasi : Jurnal Kesehatan Masyarakat Vol. 7 No. 1 (2022): Afiasi
Publisher : Universitas Wiralodra

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31943/afiasi.v7i1.196

Abstract

The existence of pollutants in hospital wastewater has the potential to pollute the environment, so they are obliged to process the liquid waste before it is released into nature. To ensure that wastewater is feasible to be discharged into the environment, it is necessary to treat it through a Wastewater Treatment Plant, one of which is the aerobic anaerobic biofilter method. This study aims to determine the effectiveness of anaerobic aerobic biofilter in reducing pollutants in wastewater in terms of the physical, chemical and biological parameters. This study uses a quasi experiment with sampling technique composite sample by time. Color and odor parameters were checked organoleptically, while pH and temperature were measured insitu using a multifunctional portable device. Parameters of BOD, COD, NH3, TSS and MPN Coliform analyzed in the laboratory for quality assurance of each sample is checked duplo. The study results of the Anutapura Hospital's wastewater treatment are still a slighly cloudy but odorless, this is not in accordance with the wastewater quality standards in the Minister of Environment Regulation Number 5 of 2014, on the contrary at Madani Hospital the color and odor parameters have met the quality standards. The values of temperature, pH, BOD, COD and TSS have met the quality standard requirements at both hospitals even from the inlet point. this is because it is good of preliminary treatment to be carried out before the wastewater flows into the biofilter. While the value of TSS and MPN coliform, at the inlet and outlet point has exceeded the quality standard. The effectiveness percentage of BOD reduction in Anutapura Hospital and Madani Hospital is 70.2% and 47.6%, for COD reduction is 53.4% and 27%, NH3 reduction 95.9% and 69.4% and TSS reduction is 65.2% and 70.2%. Based the data, concluded that increasing the percentage of biofilter effectiveness is still necessary. Keywords: anaerobic, aerobic, biofilter, WWTP
Factors Affecting Work Fatigue in Workers of Process Plan Department Area at PT Citra Palu Minerals Muhammad Sabri Syahrir; Lusia Salmawati; Muhammad Zikra; Arwan
Tadulako Social Science and Humaniora Journal Vol. 4 No. 2 (2024): Tadulako Social Science and Humaniora Journal
Publisher : LPPM Universitas Tadulako

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22487/sochum.v5i1.17182

Abstract

Work fatigue is a condition that causes a decrease in a person's efficiency and performance, so it can increase the occurrence of work accidents, and harm themselves and their companies, due to decreased productivity. The purpose of this study was to examine the effect of length of service, nutritional status, and workload on work fatigue in the processing planning department area at PT Citra Palu Minerals. This study uses quantitative research with a Cross-Sectional approach. The sampling technique in this study was determined by incidental sampling with a total sample of 54 respondents. Data collection using questionnaires, measuring instruments finger pulse oximeter, and body mass index calculation. Data analysis used is univariate, bivariate, and multivariate analysis. The results showed workload p value = 0.006 means it has a relationship with fatigue, nutritional status p value = 1,000 and tenure has p value = 0.188 means it does not have a significant relationship to fatigue in workers. The most influential factor on fatigue is workload with an Exp (B) value = 7.500.