Rancang Bangun Alat Bantu Pemeriksaan Knee Joint pada Kasus Osteoarthritis Bagus Dwi Handoko; Agung Bayu Pamungkas; Akhmad Haris Sulistiyadi
Jurnal Imejing Diagnostik (JImeD) Vol 7, No 1: JANUARY 2021
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v7i1.5855

Abstract

Background : The Knee joint is a hinge joint with a change formed by the two condyls of the femur that are jointed with the superior surface of the tibial tube. Radiographic examination of the knee joint on AP weight bearing and lateral weight bearing projections is a good projection in revealing joint gaps in the knee joint. The constraints on this examination are when patients who have little difficulty standing on one leg when doing lateral projection of weight bearing. So that a knee joint examination tool is needed in the case of osteoarthrithis.Methods : The purpose of this study was to describe the design, study the function tests and performance tests of knee joint hearing aids in the case of osteoarthrithis.This research is a type of experimental research with the design of a one shoot case study. Data collection is obtained by a check list of results of functional tests and performance test tools. The data obtained was assessed by Guttman's scale and conclusions and suggestions were drawn.This study produced a design in the form of a knee joint examination tool. The tool is made of stainless steel pipes, on a pedestal made of wooden boards, foam and cloth. Based on the calculation of the check list using the Guttman scale.Result: The function test results were 100% and the performance test results were 96%. Until the knee joint examination tool in the case of osteoarthrithis is said to be feasible to use.Conclusion : This knee joint examination aid has a number of parts, a pedestal made of wood sheets, adjustable footrests, and a patient's padded arms. The auxiliary framework uses a 3 cm diameter stainless steel pipe with a thickness of 1 mm. Based on the functional tests in the Radiology Installation of Prof. Dr. Margono Soekarjo Purwokerto obtained results 100% for knee joint examination in osteoarthritis cases with AP weight bearing projections and lateral weight bearing. Based on performance tests which involved 5 respondents who were radiographers were said to be very appropriate with a percentage of 96% with an excess of ease in operation, reducing the movement of patients, and helping the radiographers to produce informative radiographs.
Efektifitas Penambahan Source to Image Distance (SID) terhadap Penurunan Dosis Radiasi pada Pemeriksaan Radiografi Cranium Angga Yosainto Bequet; Panji Wibowo Nurcahyo; Akhmad Haris Sulistiyadi
Jurnal Imejing Diagnostik (JImeD) Vol 8, No 1: JANUARY 2022
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v8i1.8043

Abstract

Background: Cranial radiographs are routinely made in 2 projections, namely Antero Posterior (AP) and Lateral with a minimum distance of 100 cm from the radiation source to the image receptor. In addition, it has been shown that increasing the SID from 40 to 48 inches reduces the skin dose even when the requirement for an increase in mAs is considered. A 44-inch or 48-inch SID is recommended where departmental equipment and protocols allow. This study aims to determine the effectiveness of the addition of SID to decrease the radiation dose on cranium radiographs.Methods: This type of research is a pre-experimental quantitative. The study was conducted at the radiology laboratory of Diploma Three Program of Radiology Purwokerto, Semarang Health Politechnic of Ministry of Health. The research subject is a Radiographic Xray Cranial Phantom. At the time of exposure, the radiation dose was measured and the resulting image was measured CNR value.Results: The results of radiation dose measurements at each SID setting for AP cranium radiographs are shown in the table above. setting SID 100 cm produces a radiation dose of 5.58 mSv, SID 110 cm produces a radiation dose of 5.16 mSv, SID 120 cm produces a radiation dose of 5.02 mSv, SID 130 cm produces a radiation dose of 4.84 mSv, SID 140 cm produces a radiation dose of 4.64 mSv and SID 150 cm produces a radiation dose of 4.36 mSv. There are differences in radiation dose values between SID settings of 100 cm, 110 cm, 120 cm, 130 cm, 140 cm and 150 cm with a statistical test p-value 0.001. The results of statistical tests on the Contrast to Noise Ratio value on changes in the SID value of the AP cranium radiography examination showed no significant difference. The p-value of the statistical test is 0.274 which means there is no difference in the CNR value between the SID settings of 100 cm, 110 cm, 120 cm, 130 cm, 140 cm and 150 cm.Conclusions: An increase in SID causes a decrease in radiation dose. The increase in SID did not cause a significant difference to the quality of the Contrast to Noise Ratio on the AP cranium radiograph image.
INFORMASI DIAGNOSTIK GAMBARAN RADIOGRAF CERVICAL HASIL MULTIPLANAR RECONSTRUCTION CT-SCAN KEPALA Panji Wibowo Nurcahyo; Merliana Devina; Akhmad Haris Sulistiyadi; Siti Daryati
JRI (Jurnal Radiografer Indonesia) Vol. 4 No. 2 (2021)
Publisher : Perhimpunan Radiografer Indonesia (PARI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (203.123 KB) | DOI: 10.55451/jri.v4i2.94

Abstract

ABSTRACT Introduction : Data at Kenyatta National Hospital (KNH) from 2012 to 2016 recorded that there were 1,432 patients with a head injury diagnosis. Of the patients diagnosed with moderate or severe head injury, 11 (3.07%) patients had head and neck injuries. The clinical pathway in the diagnosis of head injury, CT-Scan of the brain (preferably with the inclusion of the cervical vertebrae) is now the rule in assessing traumatic brain injury. At the Radiology Installation of the Salatiga City Hospital, a head CT scan with a head injury diagnosis used a scan of the area from cervical 7 to the vertex, then cervical radiographs were made using MPR. Methods : This study uses a qualitative method with a case study approach. Data collection was carried out in March 2020 by direct observation, in-depth interviews, and documentation studies.Results : Patients diagnosed with CKS and CKB were shown cervical MPR. This MPR image has no superposition, which usually shows cervical 1 and 2 superposition with the mandible even at an angle, and in the lateral projection, cervical 7 superposition with the shoulder. The disadvantage is that the radiation dose received by the patient increases, but on radiological examination there is a justification principle, namely even though using a CT-Scan with greater radiation, the benefits obtained are also greater. In addition, burst fractures can be seen on cervical radiographs from MPR. There are fractures in trauma victims that are not fully demonstrated on radiographs at cervical 1 to cervical 2, cervical 6 to 7 cervical levels, and most involve the transverse process because the patient is uncooperative. Helical CT scanning can depict significant fractures that cannot be demonstrated on conventional radiographs and should be added to the initial screening for suspected cervical trauma.Conclusion : The cervical MPR image aims to obtain four cervical projections, namely AP, lateral, right oblique, and left oblique without conventional projections with the aim of minimizing movement in patients who are at risk of aggravating spinal cord injury. Diagnostic information from MPR results is to obtain structural visualization. specific, determine the extent of the lesion, localize the lesion and bone fragments. However, the radiation dose received is greater than conventional radiographic examinations.
Hubungan Pengetahuan dan Kepatuhan Penerapan Proteksi Radiasi: Studi pada Mahasiswa Praktik Klinik Jurusan Teknik Radiodiagnostik dan Radioterapi, Poltekkes Kemenkes Semarang Akhmad Haris Sulistiyadi; Bagus Abimanyu; Yeti Kartikasari; Susi Tri Isnoviasih
Jurnal Imejing Diagnostik (JImeD) Vol 9, No 1: JANUARY 2023
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v9i1.10442

Abstract

Background: Radiation protection is very important for patient and personnel safety in radiology services. It has been given in the college through classical lectures, including in Radiodiagnostic and Radiotherapy Department Poltekkes Kemenkes Semarang. The student’s knowledge is routinely evaluated but their compliance in the clinical activities has never been specifically observed. This study aims to find out the relationship between knowledge toward compliance of the application of radiation protection on clinical practice students.Methods: This is quantitative research with a cross-sectional design. Research was conducted on 90 second-year clinical internship students of the Radiodiagnostic and Radiotherapy Department. The level of knowledge was measured by written test, while the level of compliance was observed by clinical observation. The affecting factors are investigated through indepth interview. Data were analyzed by Spearman Rank Correlation.Results: The knowledge levels among the students were "excellent” (18%), "good" (68%), and "fair" (14%). The radiation protection compliance levels were "good" (73%) and "very good" (27%). There was a significant relationship between radiation protection knowledge level toward radiation protection compliance (p value 0.05). The strength of the relationship was low (coefficient interval = 0.257). Conclusions: There was a relationship between knowledge and the level of compliance, but it was not the only influencing factor. The environment tends to have an effect on the level of compliance. Radiographers and clinical instructors should be good role model in applying radiation protection.