Andrey Nino Kurniawan
Jurusan Teknik Radiodiagnostik dan Radioterapi Poltekkes Kemenkes Semarang

Published : 3 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 3 Documents
Search

ANALISIS PERBEDAAN INFORMASI ANATOMI PADA PEMERIKSAAN CT SCAN ABDOMEN ANTARA PENGGUNAAN PROTOKOL SURE EXPOSURE DAN TANPA SURE EXPOSURE Devita Rizkania Indarsari; Jeffry Ardiyanto; Andrey Nino Kurniawan
Jurnal Imejing Diagnostik (JImeD) Vol 5, No 2: July 2019
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jimed.v5i2.4468

Abstract

Background : Image quality Abdomen CT scan is said to be either indicated by low noise or image noise values within acceptable standard limits. One of the parameters affecting image noise is mAs. On CT Scan aircraft there is an auto mAs setting facility called Sure exposure to ensure constant image quality at the lowest possible dose. The purpose of this study was to determine the difference of anatomical information to the use of sure exposure protocol and without sure exposure on CT scan of Abdomen and to know better protocols in producing quality on CT Scan Abdomen between usage protocol sure exposure and without sure exposure.Method : This research is a kind of quantitative research with experimental approach. This study used the CT Scan Multislice 128 plane on CT scan of Abdomen with the use of sure exposure protocol and without sure exposure. The results were obtained based on respondents assessment through Liver, Spleen, Adrenal Gland, Kidney, Pancreas and Abdominal Wall. Analyze this research data using statistical test.Result : The results of the questionnaires of respondents on liver, spleen, adrenal gland, kidney, pancreas and abdominal wall showed no significant difference. This is followed by the value of Mann Whitney's overall significance of the abdominal anatomy is 0.549 (p value 0.05). Protocol Sure Exposure is better on the organ of adrenal glands, kidneys and pancreas, whereas protocols without sure exposure are better in liver, spleen, kidney, pancreas, and abdominal wall. The use of protocols without sure exposure better in generating information.Conclusion : In general the protocol of sure exposure and without sure exposure has the same clarity of anatomical information. But the protocol without a sure exposure has more information than the sure exposure protocol.
ANALISIS INFORMASI CITRA ANATOMI MSCT SCAN ORBITA POTONGAN AXIAL DENGAN VARIASI KERNEL DENGAN WINDOW SINUS DAN WINDOW BASE ORBITA PADA KASUS TRAUMA Endang Dwi Endarti; Jeffry Ardianto; Andrey Nino Kurniawan
JRI (Jurnal Radiografer Indonesia) Vol. 2 No. 2 (2019)
Publisher : Perhimpunan Radiografer Indonesia (PARI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (433.494 KB) | DOI: 10.55451/jri.v2i2.35

Abstract

Background: Trauma on the Orbits is very precisely evaluated by MSCT Scan and can analyze well the bone structure and surrounding soft tissue. One of the main parameters on MSCT Scan is the algorithm or kernel reconstruction. The improper use of the kernel can affect spatial resolution and contrast resolution, so evaluating MSCT Scan image information of Orbits with the use of window and the kernel variation is the main problem discussed. The purpose of this study was to determine differences in anatomical information on MSCT Scan of Orbits images with sinuses window variations and base orbits window with kernel of H30s Medium Smooth, H40s Medium, H70s Sharp in trauma cases and find out the best window and kernel variations in displaying anatomical information of Orbits MSCT Scan. Methods: This research is quantitative research. The research subjects were 2 Radiology Specialists as research respondents. The sample used was 10 patients. The raw data acquisition that has been obtained is reconstructed into a sinuses window and orbits base window with kernel H30s Medium Smooth, H40s Medium, H70s Sharp. Data obtained between respondents were carried out by the Cohen’s Kappa test, then the Friedman test with significance <0.05 and the best variation was obtained from the mean rank Friedman test. Results: The results of the study show that. In the variation of medium smooth H30s window and medium H40s and very sharp H70s sinus window featuring orbital walls. and most clearly in the sinus window H70s very sharp. In the window base the orbitals H30s medium smooth and H40s medium. Show clarity in the anterior chamber, lens and medial rectus muscle. Conclusion: The orbital H70s window base is very sharp showing clarity on the optic nerve, anterior chamber, lateral rectus muscle and orbital wall. Based on the results of the mean rank, the Friedman test showed that variations in the orbits window base with the Sharp H70s kernel were the best variations in each anatomic area.
PROSEDUR PEMERIKSAAN MSCT ANGIOGRAFI KEPALA DENGAN KLINIS STROKE Karina Widya Armelia; Jeffri Ardiyanto; Andrey Nino Kurniawan
JRI (Jurnal Radiografer Indonesia) Vol. 2 No. 2 (2019)
Publisher : Perhimpunan Radiografer Indonesia (PARI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (386.28 KB) | DOI: 10.55451/jri.v2i2.38

Abstract

Background : Reconstruction used to showing the patology of stroke is MPR (Multi Planar Reconstruction). Procedure reformat and filming of MSCT Angiography examination with the clinical of stroke in Radiology Hospital Dr. Moewardi just used 3D MIP, but there was dissatisfaction with the radiologist, so the radiologist do additional reformat independently. The purpose of this study was to explain the procedure of head angiography with MSCT examination in case of stroke to know the reason for head Angiography scanning and to know the reason for using reformat and filming just in 3D MIP. Methods : The type of research used a qualitative researchwith case study appoarch. The data were collected from March to April at Radiologi Hospital Dr. Moewardi by observation, interview with radiology technologist, radiologost and referring physician, and also documentation. Data were analyzed by using interactive model. Results : The result of the research shows that the procedure of Head Angiography examination with MSCT in stroke cases is done by the area from mandibula to vertex. Injection contrast media 370 mg/mL in intra vena with 90 mL and ringer laktat 30 mL. The examination began with scanning of the scanogram, pre contrast, and post contrast. Reformat and filming just in 3D MIP with AP projection, lateral, right oblique and left oblique several in positive and negative. Conclusion : The reason reformat and filming just in 3D MIP because it has revealed vascularization from various angles to be evaluated and the results obtained look like a picture of Digital Substraction Angiography (DSA), making it easier for the referring physician to carry out further examination of coiling with the DSA method.