This Author published in this journals
All Journal TRANSIENT
Melfa Silitonga
Jurusan Teknik Elektro, Fakultas Teknik – Universitas Diponegoro Jln. Prof. Sudharto, SH. Kampus UNDIP Tembalang, Semarang 50275, Indonesia

Published : 1 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 1 Documents
Search

ANALISIS OPTIMUM DISTRIBUTED GENERATION PADA KELUARAN TRANSFORMATOR UNIT I KAPASITAS 30 MVA DI GI MRICA KABUPATEN BANJARNEGARA DENGAN SOFTWARE ETAP 7.0.0 Silitonga, Melfa; Karnoto, Karnoto; Handoko, Susatyo
Transient: Jurnal Ilmiah Teknik Elektro TRANSIENT, VOL. 3, NO. 1, MARET 2014
Publisher : Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (642.092 KB) | DOI: 10.14710/transient.3.1.37-44

Abstract

Abstrak Pembangkit Distribusi adalah pembangkitan dipasang di jaringan distribusi untuk mengurangi tegangan jatuh dan rugi-rugi daya karena impedansi saluran. Pembangkit terdistribusi yang digunakan pada PENELITIAN adalah pembangkit listrik tenaga mikrohidro (PLTMH). Gardu Induk (GI) Mrica 150 kV melalui Trafo I menyuplai daya listrik ke beban di penyulang Mrica 01, Mrica 03 dan Mrica Tapen. Penyulang Mrica 01 memiliki dua DG yaitu PLTMH Karangtengah 320 kVA dan PLTMH Singgi 200 kVA, penyulang Mrica 03 tidak memiliki DG dan penyulang Mrica Tapen memiliki tiga DG yaitu PLTMH Tapen 1000 kVA, PLTMH Siteki 1200 kVA  dan PLTMH Plumbungan 1600 kVA. Sistem diatas disimulasikan ke program ETAP 7.0.0 selanjutnya dianalisis susut energi, tegangan jatuh, rugi-rugi daya, profil tegangan. Objective function dari sistem dihitung dengan bantuan Microsoft Office Excel 2007. Hasil pengujian PENELITIAN pada Trafo Unit I saat terkoneksi dan tidak terkoneksi dengan DG menunjukkan bahwa selisih susut energi adalah 0,07 % dan selisih tegangan jatuh sebesar 0,08 %. Analisis kondisi terkoneksi dan tidak terkoneksi DG menghasilkan selisih daya reaktif dan daya aktif sebesar 212,2 kVAR dan 13,5 kW. Nilai objective function Trafo Unit I paling optimum sebesar 595656,1253. Hal ini membuktikan bahwa DG sangat berpengaruh meminimalkan rugi-rugi daya, tegangan jatuh dan objective function. Kata Kunci : Pembangkit Terdistribusi (DG) , Daya Aktif, Daya Reaktif, drop voltage, Objective function , Profil Tegangan, Software ETAP 7.0.0, Microsoft Office Excel 2007.  Abstract DG is a generation that installed in distribution network to reduce drop voltage, power losses because of line impedance. DG used in this final assigment is PLTMH. Substation Mrica 150 kV through the Trafo Unit I supplies electrical power to load feeders Mrica 01, Mrica 03, Mrica Tapen. Mrica 01 load feeder has two DG, those are PLTMH Karangtengah 320 kVA, PLTMH Singgi 200 kVA. Mrica 03 load feeder doesn’t have DG, Mrica Tapen load feeder has three DG, those are PLTMH Tapen 1000 kVA, PLTMH Siteki 1200 kVA, PLTMH Plumbungan 1600 kVA. It was simulated by ETAP 7.0.0 software, analysis the energy losses, drop voltage, power loss, profile of voltage. Objective function was made, calculated by Microsoft Office Excel 2007. Test result on the final project of Trafo Unit I when it was connected, not connected to DG shows in energy losses was 0,07 %, drop voltage was 0,08 %. Analysis it was connected, not connected to DG results a reative power, active power 212,2 kVAR, 13,5 kW consecutively. The most optimum Objective function of Trafo Unit I  was 595656,1253. The result proves that the DG is very important to minimize power losses, drop voltage and the objective function. Keyword :            Distributed generation ( DG ), Active Power , Reactive Power , drop voltage, Objective function , voltage profile , ETAP Software 7.0.0, Microsoft Office Excel 2007.