Roto Roto
Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Gadjah Mada, Sekip Utara PO BOX BLS 21 Yogyakarta 55281

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

Characterization of Butanediol-Alginate Ester as Candidate of Hemodialysis Membrane Choirul Amri; Mudasir Mudasir; Dwi Siswanta; Roto Roto
Indonesian Journal of Chemistry Vol 15, No 2 (2015)
Publisher : Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (374.355 KB) | DOI: 10.22146/ijc.21208

Abstract

An ester of butanediol-alginate has been studied as a possible hemodialysis membrane. With 1,4-butanediol molar ratio of 0.1, 0.5, and 1.0, it showed that the membrane mechanical properties, stability, protein adsorption, platelet adhesion and performance for urea and creatinine clearance are better than that of unmodified alginate. The increase in 1,4-butanediol molar ratio causes hemodialysis ratio to improve, and causes protein adsorption and platelet adhesion at the membrane surface to decrease. In the case of protein adsorption and platelet adhesion, the membrane with the molar ratio of 1.0 has better hemocompatibility properties. In the hemodialysis test for 4 h, using 2.742 mg cm-2 h-1 of urea and 0.058 mg cm-2 h-1 of creatinine flux, this membrane showed that 48.5% of urea and 44.2% of creatinine were cleaned.
PAN-Immobilized PVC-NPOE Membrane for Environmentally Friendly Sensing of Cd(II) Ions Moersilah Moersilah; Dwi Siswanta; Roto Roto; Mudasir Mudasir
Indonesian Journal of Chemistry Vol 17, No 1 (2017)
Publisher : Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (351.228 KB) | DOI: 10.22146/ijc.23544

Abstract

A simple, cheap and environmentally friendly analytical method of Cd(II) in the aqueous system has been developed by immobilization of 1-(2-pyridilazo)-2-naphtol (PAN) in poly vinyl chloride (PVC) matrix and nitrophenyl octyl ether (NPOE) as a plasticizer. Upon contact with Cd(II) in solution, the color of sensor membrane changes from dark yellow to dark red, which is due to the formation of Cd(II)–PAN complex. The best sensing results were obtained at pH 8.0 and λmax 558 nm. The dimension of the proposed sensor membrane was 0.8 cm x 2 cm with a thickness of 0.05 mm, the volume of sample was 2 mL with the Cd(II) concentration range of  0 – 1.2 ppm. The limit of detection of the method was found to be 0.432 + 0.104 ppm, which was reversible. The proposed methods have been applied in the determination of Cd(II) in water samples after addition of internal standard.