Claim Missing Document
Check
Articles

Found 2 Documents
Search

Pengujian Instrumen Pendeteksi Kelainan Ritme Jantung Menggunakan Data Fisiologi MIT-BIH M. S. Hendriyawan A.; Indah Soesanti; Litasari
Jurnal Nasional Teknik Elektro dan Teknologi Informasi Vol 2 No 2: Mei 2013
Publisher : Departemen Teknik Elektro dan Teknologi Informasi, Fakultas Teknik, Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1044.755 KB)

Abstract

MIT-BIH database provides authentic ECG signal data that can be used as a source to test the system with varied type of disorders and duration of observation. MIT-BIH ECG signals are converted to analog signals using 11-bit DAC with 360 Hz frequency conversion. Microcontroller converts the analog signals from the output of the generator using an internal 10-bit ADC with a sampling frequency of 200 Hz. Cardiac abnormalities are then analysed based on data sampling. Abnormal heart rhythms are identified using R peak parameter. By measuring the interval between R peaks, the number of beats per minute (bpm) and the interval variation between R peaks can measured to determine abnormal heart rhythms. Results show that DAC output obtains error range from 6.72 milivolt to 14.58 milivolt, whereas ADC output obtains error range from 1 bit to 2 bit. Statistically, test results show significance values from ideal values are greater than α = 0,05 meaning that there is no significant difference between measured R-R intervals with the original R-R intervals by 95% confidence level. The test method successfully detects multiple type of heart rhythms with category: normal, bradycardia, tachycardia, and irregular.
Perancangan Jaringan Nirkabel untuk Infrastruktur Monitoring Deformasi Bendungan Sermo Addin Suwastono; Bambang Sutopo; Litasari
Jurnal Nasional Teknik Elektro dan Teknologi Informasi Vol 1 No 3: Agustus 2012
Publisher : Departemen Teknik Elektro dan Teknologi Informasi, Fakultas Teknik, Universitas Gadjah Mada

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (610.699 KB)

Abstract

Wireless local area networks is used by Sermo’s GNSS-CORS to renew its reference position from Department of Engineering Universitas Gadjah Mada’s CORS.The problem is, that wireless local area network should meet the bandwidth requirement and the operation should not break the frequency usage regulation in Indonesia.This reseach was conducted to study the bandwidth needs of Sermo’s dam deformation monitoring system, to design the topology, and calculating EIRP of all wireless network link in the system that meet the regulations of the Ministry of Communications and Information Republik of Indonesia. Wireless local area networks was built to connect Sermo, Faculty of Engineering Universitas Gadjah Mada and Balai Besar Wilayah Sungai Serayu Opak’s office.Design implementation and testing of broadband wireless equipment at unlicence frequency of 2.4 GHz (Motorola PTP 100) and 5.8 GHz (Motorola Motorola PTP and PTMP 5750AP/5760SM 58 300) resulted in 2.22 Mbps bandwidth that is much greater than that required, 128.7 kbps, and the average round trip delay of 19.2 ms. Antenna alignment information can be used as a reference for wireless communications equipment maintenance.