ANALISA KOROSI PIPA SOLAR MESIN DIESEL DI SEBUAH PT. X Syafrizal
Jurnal Konversi Energi dan Manufaktur Vol 3 No 2 (2016): JKEM : Jurnal Konversi Energi dan Manufaktur UNJ Vol. 3 No 2 Tahun 2016
Publisher : Universitas Negeri Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (624.793 KB) | DOI: 10.21009/JKEM.3.2.4

Abstract

Telah terjadi korosi yang menimbulkan kebocoran pipa di Jakarta pusat dikarenakan pipa mengalami korosi, terkikis dan berlubang. Pipa bersentuhan dengan tanah cukup lembab dan diketahui tanah sekitar pipa memiliki kandungan garam dan ion Cl- yang dikenal cukup agresif, sehingga laju korosi pada pipa dapat terjadi lebih cepat. Lingkungan instalasi pipa sangat dekat dengan jalan raya dan bergetar, permukaan pipa lebih cepat terkikis, menipis dan berlubang seperti yang diperlihatkan pada gambar 2. Hasil pengukuran bahwa area kebocoran pipa (11 x 11,3)mm, karena minyak solar juga mengandung sulfur cukup tinggi sehingga membentuk larutan asam sulfat dengan air, asam sulfat dapat mempercepat laju korosi pada pipa baja. Untuk mencegah kejadian serupa maka telah diusulkan desain konstruksi pipa dengan tumpuan yang memungkinkan untuk sebuah solusi, karena dapat mencegah gesekan permukaan pipa dengan tanah dan mencegah reaksi garam dengan pipa. Penambahan biaya konstruksi pipa dengan tumpuan sekitar 5%, hal ini bukanlah angka yang besar jika dibandingkan dengan umur pakai. Secara keseluruhan 3 faktor desain tersebut lebih menguatkan bahwa pengembangan desain konstruksi pipa perlu dilakukan sehingga pipa lebih aman dari efek teknis dan korosi lingkungan, serta umur pakai pipa dapat lebih lama.
Analisis Kinerja R290 sebagai Pengganti R32 pada Unit AC-Split Kapasitas 9,000 Btuh/hr Widodo; Ade Irvan Tauvana; Fatkur Rachmanu; Lukman Nulhakim; Syafrizal; Mokhamad Is Subekti
Jurnal Asiimetrik: Jurnal Ilmiah Rekayasa & Inovasi Volume 4 Nomor 2 Tahun 2022
Publisher : Fakultas Teknik Universitas Pancasila

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35814/asiimetrik.v4i1.3466

Abstract

R290 is a type of natural refrigerant that has ODP = 0 and GWP = 4. While R32 from synthetic materials has ODP= 0 and GWP = 675 both are refrigerants used in Split AC. With this high GWP, it can have a damaging impact on the atmosphere. The advantage of R290 is that it has a lower density compared to R32, which can save the number of fillings in the AC unit by ±30% of the previous amount of refrigerant in the same volume. R290/R32 was flammable with LFL= 2%/13% and UFL= 10%/33%. The purpose of this study was to analyze the performance of R290 as a substitute for R32 on an AC-split unit with a capacity of 9,000 Btuh/hr. The steps used in the test are that the AC unit is placed in an open room with ambient temperature around 32°/80°C. The test was carried out until it reaches the optimal and stable temperature, then data is collected. The results of data collection from the evaporator air temperature R290/R32 = 21.4°C/23.0°C, condenser air temperature = R290/R32= 35°C/38.5°C, suction pressure= 90 psig/130 psig and discharge 200 psig/420 psig. The test data were analyzed and calculated using the Mollier Chart software with the results = R290/R32 = refrigeration effect = 344.8/272.2 kJ/kg, compression work = 12.18/13.02 kJ/kg, COP = 28.3/20.9, compression ratio = 2.2/3.2, strong electric current 4.98/5.73 A. From the decrease in electric current of R290 obtained a savings of 13.3% was obtained when converted to electricity bill payment and get a profit of 45,886/month.