SENSOR-SENSOR PEMANTAU MENGGUNAKAN ARDUINO UNO DAN ESP8266 DIUNGGAH KE THINGSPEAK SERVER UNTUK PENGUKURAN GASDI TEMPAT PEMBUANGAN AKHIR MANGGAR BALIKPAPAN charles pangaribuan; agus beny imron
Jurnal Teknik Elektro Uniba (JTE UNIBA) Vol. 1 No. 1 (2016): Jurnal Teknik Elektro Uniba (JTE UNIBA)
Publisher : Lembaga Penelitian Universitas Balikpapan

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1192.635 KB)

Abstract

Abstract—Oil and gas industri is one of very development sector in technology. The data acquisition system or telemetry with remote monitoring and storage are one of them. Today, this technology can be applicated into society to be usefull and give more advantages. By using an open data platform for Internet of Things (IoT), it is very possible. -Final landfil has produced many gasses such as methane and carbondiokside, especially methane gas which is produced by deterioration of organic waste. These emit gasses are one global warming root caused, we call it green house effect gasses. The gas concentrations is hard to be measured without a device help, it is safe and prefered. -On this final project the we build build a prototype that contain Arduino Uno, ESP826 Wi-Fi module and Sensors. It detects reading for Methane (CH4) , Carbon Dioxide (CO2), Temperature and Humidity. All reading data for gasess, temperature and humidity then send throught Wi-Fi internet be uploaded into www.thingspeak.com,using internet browser we can view the reading graph from ThingSpeak, anyone who has internet acces can be seen all the dataremotel
Perancangan Alat Untuk Optimalisasi Pemakaian Energi Listrik untuk Rumah Tinggal Hemat Energi charles pangaribuan; iwan setiawan
Jurnal Teknik Elektro Uniba (JTE UNIBA) Vol. 1 No. 1 (2016): Jurnal Teknik Elektro Uniba (JTE UNIBA)
Publisher : Lembaga Penelitian Universitas Balikpapan

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (646.9 KB)

Abstract

Abstract— The use of electrical energy in houses sometimes not optimal and inefficient, because during the houses the have been left by the owner sometimes tedapat the lights or an electrical device that there was really no need operated but still operating, this is what lead to the use of electrical energy vain.To address this so perlulah made a an electronic device that beneficial to control the use of electrical energy home live that devices electricity unnecessary functioned can be made inactive by a device that fitted. A device that made is software of programming c language adjusted with the regulation discharging electricity energy planned and will be upload into device microcontroller electrical Circuit. This Microcontroller also have relay, keypad and other devices supporting from apparatus produces by results according to which planned namely device electricity can active or inactive at the device electicity made this is very effective used in building with installation that uses electric power large
ANALISA PROSES PENGUKURAN DAN TEST LOAD ALTERNATOR 35A, 60A DAN 100A DENGAN BEBAN BERVARIASI DI PT. U charles pangaribuan; imran saputra
Jurnal Teknik Elektro Uniba (JTE UNIBA) Vol. 1 No. 2 (2017): Jurnal Teknik Elektro Uniba (JTE UNIBA)
Publisher : Lembaga Penelitian Universitas Balikpapan

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (751.756 KB)

Abstract

Abstract-The charging system is part of the electricity in the machine, in the fuel refueling system for full load conditions as well as must. In doing the Overhoul Alternator must be ascertained the condition of the components such as Stator, Rotor and Diode Rectifier in good condition. A good Stator and Rotor have a 35 Ohm coil Resistance and a minimum resistance of 0.5 Mohm.. In performing Test Load Alternator, to get a good test results required data varying each 25%, 50%, 75% and 100% of the capacitance of each alternator. Test Load process using DURST TB-1900A. Varitive loading is seen from the large Alternator output current in which every Alternator load must have a stable output voltage of 27.5 Volts - 28.5 Volts.From test load Alternator results obtained that Alternator with capacity 35 A and 100 A in good condition while for Alternator with the capacity 60 A is not in good condition.