EVALUASI KINERJA INSTALASI PENGOLAHAN AIR LIMBAH (IPAL) DI WADUK MELATI, KOTA JAKARTA PUSAT Mahardika Saputra; Etih Hartati; Nico Halomoan
Jurnal Teknik Lingkungan Vol. 22 No. 2 (2016)
Publisher : ITB Journal Publisher, LPPM ITB

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.5614/j.tl.2016.22.2.6

Abstract

Abstrak: Instalasi Pengolahan Air Limbah (IPAL) Waduk Melati berfungsi untuk mengurangi beban pencemaran air limbah yang masuk ke dalam waduk yang dapat berpotensi menyebabkan adanya pencemaran air dan berdampak pada kesehatan. Penelitian ini bertujuan untuk mengevaluasi kinerja IPAL Waduk Melati dengan membandingkan  efisiensi dan kriteria desain unit pengolahan. Data kualitas air dibandingkan dengan baku mutu Permen LH No. 68 Tahun 2016, sedangkan kriteria desain dibandingkan dengan literatur menurut Qasim (1985). Hasil evaluasi terhadap efisiensi unit pengolahan menunjukan parameter total coliform tidak memenuhi baku mutu yang dipersyaratkan. Berdasarkan hasil evaluasi unit pengolahan terhadap kriteria desain diketahui bahwa pada unit bar screen yang tidak memenuhi kriteria desain adalah jarak antar bar coarse screen dan jarak antar bar fine screen. Sedangkan pada unit RBC yang tidak memenuhi kriteria desain adalah waktu detensi organic loading rate dan hydarulic loading rate. Pada tangki aerasi yang tidak memenuhi kriteria desain yaitu volumetric loading, rasio makanan terhadap mikroorganisme dan waktu detensi. Dan pada bak sedimentasi yang tidak memenuhi kriteria desain yaitu overflow rate  dan solid loading. Kata kunci: air limbah domestik, IPAL Waduk Melati., RBC, tangki aerasi,Abstract: Wastewater Treatment Plant (WWTP)  Waduk Melati serves to reduce of wastewater pollution loading goes into Waduk Melati that can potentially cause pollution and impact to health. This study aims to evaluate the performance of WWTP, compare againts efficiency and design criteria of the processing unit. Water quality data compared to the quality standard  from Minister of  Environment Regulations No. 68 Year 2016, while the design criteria are compared with the literature according to Qasim (1985). The result of evaluation of treatment units showed the total coliform parameter did not meet the regulation. Based on the evaluation of the processing unit on the design criteria, it is known that on bar screen unit that do not meet the design criteria are the distance between the coarse screen barand the distance between the fine screen bar. While the RBC unit that does not meet the design criteria is the detention time, organic loading rate and hydarulic loading rate. In aeration tanks that do not meet the design criteria of volumetric loading the ratio of food to microorganisms and detention time. And on the sedimentation basin that does not meet the design criteria of overflow rate and solid loading.  Keywords: domestic wastewater, WWTP Waduk Melati, RBC, aeration tank,.