Neila Yenni
Unknown Affiliation

Published : 2 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search

DEGRADASI SENYAWA PARAQUAT DALAM PESTISIDA GRAMOXONE® SECARA SONOZOLISIS DENGAN PENAMBAHAN TiO2-ANATASE Yenni, Neila; Safni, Safni; Suyani, Hamzar
Jurnal Riset Kimia Vol 3, No 2 (2010): March
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/jrk.v3i2.58

Abstract

 ABSTRACT Degradation of Paraquat compound in Gramoxone pesticide had been done by sonolysis, ozonolysis, and sonozolysis. Sonolysis methods were performed using an ultrasound VC-1, ozonolysis using a bio-ozone space age sterilizer, and sonozolysis by combining sonolysis and ozonolysis methods. The optimum condition for degradation of 4 mg/L paraquat by sonolysis was found at temperature 40±1°C. Percentage of degradation at optimum condition was 22.80% with 90 minutes treatment. Whereas, with using ozonolysis method percentage of degradation of paraquat 4 mg/L was 50.39% with 60 minutes treatment. The combination of sonolysis and ozonolysis method simultaneously, these so-called sonozolysis, for degradation of the same compound, extend the percentage of degradation to 45.87% with only 30 minutes treatment. Keywords: Paraquat, Sonolisis, Ozonolisis
DEGRADASI SENYAWA PARAQUAT DALAM PESTISIDA GRAMOXONE® SECARA SONOZOLISIS DENGAN PENAMBAHAN TiO2-ANATASE Neila Yenni; Safni Safni; Hamzar Suyani
Jurnal Riset Kimia Vol. 3 No. 2 (2010): March
Publisher : Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.25077/jrk.v3i2.58

Abstract

 ABSTRACT Degradation of Paraquat compound in Gramoxone pesticide had been done by sonolysis, ozonolysis, and sonozolysis. Sonolysis methods were performed using an ultrasound VC-1, ozonolysis using a bio-ozone space age sterilizer, and sonozolysis by combining sonolysis and ozonolysis methods. The optimum condition for degradation of 4 mg/L paraquat by sonolysis was found at temperature 40±1°C. Percentage of degradation at optimum condition was 22.80% with 90 minutes treatment. Whereas, with using ozonolysis method percentage of degradation of paraquat 4 mg/L was 50.39% with 60 minutes treatment. The combination of sonolysis and ozonolysis method simultaneously, these so-called sonozolysis, for degradation of the same compound, extend the percentage of degradation to 45.87% with only 30 minutes treatment. Keywords: Paraquat, Sonolisis, Ozonolisis