Claim Missing Document
Check
Articles

Found 2 Documents
Search

Review pengaruh penetrasi photovoltaic terhadap loss of life dan kinerja transformator Rahman Azis Prasojo; Rohmanita Duanaputri; Jamik Apriliasari; Rosina Ahda Dini; Devi Soviati Mahmudah
JURNAL ELTEK Vol 20 No 2 (2022): ELTEK Vol 20 No 2
Publisher : Politeknik Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (222.016 KB) | DOI: 10.33795/eltek.v20i2.357

Abstract

ABSTRAK Salah satu peralatan yang penting dalam sistem distribusi tenaga listrik adalah transformator. Penuaan transformator disebabkan oleh kerusakan isolasi yang diakibatkan dari proses degradasi kimia yang terakselerasi oleh oksidasi dan peningkatan suhu. Maka dari itu, untuk menilai loss of life transformator yang paling umum digunakan adalah menggunakan karakteristik thermal transformator. Peningkatan penggunaan photovoltaic (PV) yang mulai menyebar di berbagai daerah adalah salah satu bukti mulai diandalkannya energi terbarukan. Hal ini membawa dampak positif maupun negatif, baik bagi sistem tenaga secara keseluruhan, maupun bagi peralatan listrik. Artikel ini membahas berbagai penelitian terdahulu yang meneliti tentang pengaruh penggunaan PV terhadap penurunan kondisi transformator distribusi. Artikel review ini dibagi menjadi tiga bagian. Yang pertama membahas tentang akibat pemasangan PV yang mempengaruhi kinerja dari isolasi transformator berdasarkan pembebanan yang dialami saat operasi. Yang kedua membahas tentang pengaruh harmonisa yang dihasilkan oleh sistem PV terhadap penuaan transformator. Yang terakhir membahas tentang beberapa penelitian terdahulu yang membahas pendekatan untuk mengatasi harmonisa pada sistem. ABSTRACT One of the most important equipment in an electric power distribution system is a transformer. Transformer aging is caused by insulation breakdown resulted from chemical degradation processes that are accelerated by oxidation and increasing temperature. To assess the loss of life of the transformer, the most commonly used is to use the thermal characteristics of the transformer. The increasing use of photovoltaic which is starting to spread in various regions is one proof that renewable energy is starting to be relied on. This has both positive and negative impacts, both for the power system as a whole and for electrical equipment. This article discusses various previous studies that examined the effect of the use of photovoltaic on the deterioration of the distribution transformer condition. This review article is divided into three parts. The first is the effect of PV penetration which affects the performance of the transformer insulation based on the loading during operation. The second is the effect of harmonics generated by the PV system on the transformer aging. The last is to discuss some of the previous studies that proposed methods in reducing harmonics in the system.
Analisis Audit Energi di Hotel Kota Malang Menggunakan Web-Based Monitoring System Ahmad Hermawan; Rosina Ahda Dini; Chandra Wiharya
Elposys: Jurnal Sistem Kelistrikan Vol. 10 No. 2 (2023): ELPOSYS vol. 10 no. 2 (2023)
Publisher : Politeknik Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33795/elposys.v10i2.1219

Abstract

Energy audits are evaluation activities carried out to determine the condition of the energy used in a system. Audits are carried out to provide the efficiency of an electrical system. The first energy audit conducted was the initial energy audit. By using the specifications of the installed electrical system and using monitoring data. Followed by a detailed energy audit, to determine the condition of a more specific electrical system. The data used is measurement/monitoring data, and data calculations are then compared with the provision of the electricity standard. In calculating the intensity of energy consumption in the initial energy audit process, the IKE Fave Hotel results were still by the standards with an IKE value of 213.59 kWh/m2. Meanwhile, based on the results of a detailed energy audit, it was found that the lighting system and cooling system were not up to standard because the lux results for several rooms showed results that were less than the lux standard. Thus, it is necessary to provide recommendations for improvements to the lighting and cooling system. Providing lighting recommendations can use dialux as a calculation comparison. In the lighting system, it is necessary to replace some of the lamp specifications installed because they are far from standard values. This also needs to be done on the cooling system, by replacing the installed air conditioner according to existing calculations. This replacement was carried out to save energy for the continuity of the hospitality industry process at Fave Hotel Malang.