Review pengaruh penetrasi photovoltaic terhadap loss of life dan kinerja transformator Rahman Azis Prasojo; Rohmanita Duanaputri; Jamik Apriliasari; Rosina Ahda Dini; Devi Soviati Mahmudah
JURNAL ELTEK Vol 20 No 2 (2022): ELTEK Vol 20 No 2
Publisher : Politeknik Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (222.016 KB) | DOI: 10.33795/eltek.v20i2.357

Abstract

ABSTRAK Salah satu peralatan yang penting dalam sistem distribusi tenaga listrik adalah transformator. Penuaan transformator disebabkan oleh kerusakan isolasi yang diakibatkan dari proses degradasi kimia yang terakselerasi oleh oksidasi dan peningkatan suhu. Maka dari itu, untuk menilai loss of life transformator yang paling umum digunakan adalah menggunakan karakteristik thermal transformator. Peningkatan penggunaan photovoltaic (PV) yang mulai menyebar di berbagai daerah adalah salah satu bukti mulai diandalkannya energi terbarukan. Hal ini membawa dampak positif maupun negatif, baik bagi sistem tenaga secara keseluruhan, maupun bagi peralatan listrik. Artikel ini membahas berbagai penelitian terdahulu yang meneliti tentang pengaruh penggunaan PV terhadap penurunan kondisi transformator distribusi. Artikel review ini dibagi menjadi tiga bagian. Yang pertama membahas tentang akibat pemasangan PV yang mempengaruhi kinerja dari isolasi transformator berdasarkan pembebanan yang dialami saat operasi. Yang kedua membahas tentang pengaruh harmonisa yang dihasilkan oleh sistem PV terhadap penuaan transformator. Yang terakhir membahas tentang beberapa penelitian terdahulu yang membahas pendekatan untuk mengatasi harmonisa pada sistem. ABSTRACT One of the most important equipment in an electric power distribution system is a transformer. Transformer aging is caused by insulation breakdown resulted from chemical degradation processes that are accelerated by oxidation and increasing temperature. To assess the loss of life of the transformer, the most commonly used is to use the thermal characteristics of the transformer. The increasing use of photovoltaic which is starting to spread in various regions is one proof that renewable energy is starting to be relied on. This has both positive and negative impacts, both for the power system as a whole and for electrical equipment. This article discusses various previous studies that examined the effect of the use of photovoltaic on the deterioration of the distribution transformer condition. This review article is divided into three parts. The first is the effect of PV penetration which affects the performance of the transformer insulation based on the loading during operation. The second is the effect of harmonics generated by the PV system on the transformer aging. The last is to discuss some of the previous studies that proposed methods in reducing harmonics in the system.
Penilaian Kualitas Gas SF6 Pada GISTET 500/150 kV Rahman Azis Prasojo; Devi Soviati Mahmudah; Imron Ridzki; Muhammad Fahmi Hakim; Priya Surya Harijanto
Elposys: Jurnal Sistem Kelistrikan Vol. 9 No. 3 (2022): ELPOSYS vol.9 no.3 (2022)
Publisher : Politeknik Negeri Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (613.186 KB) | DOI: 10.33795/elposys.v9i3.643

Abstract

The number of Gas Insulated Switchgear (GIS) in operation is increasing in Indonesia. GIS failure requires expensive costs andextensive blackouts. Asset reliability management such as SF6 is needed to ensure GIS performance. Several studies have tested thequality of SF6 gas to assess the feasibility and operation of the GIS. However, a complete GIS feasibility study based on SF6 gas qualityparameters has not found. In this study, a condition assessment of the GISTET Kembangan 500/150 kV was carried out based on applicableinternational standards. There is an interesting phenomenon in the form of dew point anomaly and moisture content in severalcompartments, indicating that the gas is moist. The results of this study indicate the operational feasibility of the GISTET Kembangan500/150 kV , the effect of high humidity on GIS operations, and maintenance recommendations.