Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : JHP17 (Jurnal Hasil Penelitian)

ANALISA LUASAN LUBANG VENTILASI FACADE TERHADAP LUASAN LANTAI ., Mufidah; Murti, Farida; Bintarjo DH, Benny; Pratama, Hanny Chandra; Tri Putranto, Yunantyo
JHP17 (Jurnal Hasil Penelitian) Vol 1 No 02 (2016)
Publisher : Lembaga Penelitian Dan Pengabdian Kepada Masyarakat Universitas 17 Agustus 1945 Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Flat development is a response for citizen dwelling needs, especially for the citizen who have a lower economic, problem of lands high cost, and limited lands. Based for the problem, The Indonesian government has made a policy to built rental flats or belonging flats as a solution. On the flat development, one of criteria should applied is facade of a flat which can reduce heat thermal into buildings. This study is a second part which made a recommendation of flat mass to get comfortable thermal value by natural energy. While, this second study for identify a design recommendation of flat facade to get comfortable thermal value by natural energy. This method of study uses some literatures related on arranger a facade on the flats. The correlate variable is about materials and ventilation. Ventilation is about wide, position, and model of ventilation on the building. Besides that, explore the facade and analyze based for land efficiency, occupant’s behavior, building aesthetics, wind flow optimizing, sunlight optimizing and heat insulation into building. Result of this study is get a saving energy flat model on warm-humid climate. Focus on optimize the facade of the buildings to get comfortable value for the occupants.Keywords: flat facade, energy saving, warm-humid climate
OPTIMASI PENCAHAYAAN ALAMI PADA STUDIO ARSITEKTUR DI UNIVERSITAS 17 AGUSTUS 1945 SURABAYA Masruchin, Febby Rahmatullah; Mufidah, Mufidah
JHP17 (Jurnal Hasil Penelitian) Vol 4 No 2 (2019)
Publisher : Lembaga Penelitian Dan Pengabdian Kepada Masyarakat Universitas 17 Agustus 1945 Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The enthusiasm as the user of the room in the building can work well and comfortably, if in the building get enough lighting in accordance with the function of the room. Lighting in buildings comes from natural lighting, the source of which is sunlight and artificial lighting from light bulbs. The use of natural lighting in buildings, in addition to not having too much heat in the room, can also reduce the cost of using electricity. There are a lot of lecture rooms at Untag Surabaya campus, if in each lecture room can use natural lighting in the building, it will certainly be able to reduce the operational costs quite a lot. In this study, studio B's lecture room was selected in Untag Surabaya Architecture, to be simulated using Ecotect 5.5 software to obtain optimal natural lighting in the building. The building variables used as modifiers are window proportion, window position, color change, change in ceiling height, as well as the difference in the base of the building. The final results of this study are expected to get optimal classroom recommendations for learning by using natural lighting, so as to reduce the cost of using electricity.  Keywords : natural lighting, studio class room, saving electricity energy K