THE DESIGN OF RADIOLOGY VIEWING BOX USING POTENTIOMETER SYSTEM Diartama, Anak Agung Aris; Suswaty, Susy; Priantoro, Win; Sudiyono, Sudiyono; Sugiyanto, Sugiyanto; Anwar, Muhammad Choiroel; Latifah, Leny; Santjaka, Aris; Amri, Faisal; Mulyantoro, Donny Kristanto
Proceedings of the International Conference on Applied Science and Health No 1 (2017)
Publisher : Proceedings of the International Conference on Applied Science and Health

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (589.82 KB)

Abstract

Background: In the process of work to gain the maximum results, a radiologist needs a viewing box tool to read radiographs. Aims: to create a viewing box tool by using a potentiometer system. Methods: This study used applied research method by creating and using the design of viewing box tool by using a potentiometer system and testing the viewing box tool created by using a Lux meter and 15 respondents consisting of five radiologists and 10 radiographers who should fulfill the questionnaire form. Results: The mean of viewing box illumination reached 220 lux. The results of the questionnaire showed that 100% radiologist gave an A (excellent) and expressed that the viewing box tool created could be used properly and 90% radiographers provided an A (excellent) and expressed that the viewing box tool created could be used properly, while 10% radiographer gave a value of B (moderate). Conclusion: viewing box tool created could be used properly and obtained optimal results as a tool in reading radiographs. Potentiometer system contained in the viewing box was very helpful in reading radiographs because it allowed to adjust the light intensity according to user needs. 
The design of radiology viewing box using light emitting diode and potentiometer Diartama, Anak Agung Aris; Suswaty, Susy; Priantoro, Win; Sugiyanto, Sugiyanto; Sudiyono, Sudiyono; Anwar, M. Choiroel; Latifah, Leny; Santjaka, Aris; Amri, Faisal; Mulyantoro, Donny Kristanto
Global Health Management Journal Vol 1, No 1 (2017)
Publisher : Yayasan Aliansi Cendekiawan Indonesia Thailand (Indonesian Scholars' Alliance)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (662.16 KB)

Abstract

Background: In the process of work to gain the maximum results, a radiologist needs a viewing box tool to read radiographs. Therefore, the authors want to develop a viewing box tool, which in general the work if this tool resembles the factory manufactured tool. The viewing tool box made can adjust the intensity of the light produced.Objective: to create a viewing box tool by using a potentiometer system.Methods: This study used applied research method by creating and using the design of viewing box tool by using a potentiometer system and testing the viewing box tool created by using a Lux meter and 15 respondents consisting of five radiologists and 10 radiographers who should fulfill the questionnaire form.Results: The mean of viewing box illumination reached 220 lux. The results of the questionnaire showed that 100% radiologist gave an A (excellent) and expressed that the viewing box tool created could be used properly and 90% radiographers provided an A (excellent) and expressed that the viewing box tool created could be used properly, while 10% radiographer gave a value of B (moderate).Conclusion: viewing box tool created could be used properly and obtained optimal results as a tool in reading radiographs. Potentiometer system contained in the viewing box was very helpful in reading radiographs because it allowed to adjust the light intensity according to user needs.Keywords       :  Viewing box, Potentiometer Bibliography   : 1980-2011