Jurnal Imejing Diagnostik
Vol 5, No 2: July 2019

PERBEDAAN PENERAPAN ACCELERATION FACTOR TERHADAP KARAKTERISTIK CITRA DIAGNOSTIK T2WI FSE PADA MRI LUMBAL KASUSHERNIATED NUCLEUS PULPOSUS (HNP)

Maulidya Nasokha Ildsa (Jurusan Teknik Radiodiagnostik dan Radioterapi Poltekkes Kemenkes Semarang)
Gatot Murti Wibowo (Jurusan Teknik Radiodiagnostik dan Radioterapi Poltekkes Kemenkes Semara)
Emi Murniati (Jurusan Teknik Radiodiagnostik dan Radioterapi Poltekkes Kemenkes Semara)



Article Info

Publish Date
15 Jul 2019

Abstract

Background: Patients with HNP cases have a bigger chance to do a movement during MRI examination, and it causes poor MRI image. Quick time of MRI examination is needed to produce an optimal image. The technique of parallel imaging is a technique that can increase the speed of MRI data acquisition by passing through several lines of phase encoding in k-space. The GRAPPA technique is one of the methods used to reconstruct data on MRI parallel imaging techniques with better overall image quality. The technique of parallel imaging has a special parameter called acceleration factor. Acceleration factor (R-factor) will affect scan time. The purpose of this research is to know the difference of diagnostic image characteristic which is resulted in applying acceleration factor 2, 3 and 4 in parallel imaging of GRAPPA method and know the optimal acceleration factor to obtain MRI image of lumbar HNP case.Methods: This research type is quantitative research with descriptive approach. The study was conducted by MRI Siemens 3 T in RSUD Dr. Soedono Madiun. The data were 30 MRI images of lumbar sagittal of HNP cases on T2WI FSE with acceleration factor 2, 3 and 4 GRAPPA methodsResult: The results of this study indicate that there are differences in diagnostic image characteristics in the application of acceleration factor 2 and 4, 3 and 4 with VGA test. Acceleration factor value optimal with VGC test known is acceleration factor 2 and 3Conclusion: Based on the result there were differencediagnostic image characteristics of MRI Lumbar in sagital plane Fast Spin Echo (FSE)sequence with variation acceleration factor 2, 3 and 4 parallel imaging GRAPPA methode in case Herniated Nucleus Pulposus (HN0). The optimal value of variation acceleration factor value for MRI Lumbar examination of Heniated Nucleus Pulposus (HNP) is 2 dan 3.

Copyrights © 2019






Journal Info

Abbrev

jimed

Publisher

Subject

Health Professions Medicine & Pharmacology

Description

Jurnal Imejing Diagnostik (JImeD) memuat tulisan ilmiah dalam bidang radiologi berupa hasil penelitian dan non penelitian (konseptual). Jurnal Imejing Diagnostik (JImeD) terbit 2 kali dalam satu tahun yaitu pada bulan Januari dan Juli oleh Jurusan Teknik Radiodiagnostik dan Radioterapi, Politeknik ...