Padjadjaran Journal of Dentistry
Vol 31, No 2 (2019): July 2019

Comparison of the quality of the result of digitising panoramic analogue films using transmission and reflection scanner mode with direct digital imaging standard

Azhari Azhari (Universitas Padjadjaran)
Gianto Gianto (Bandung Institute of Technology)
Suprijanto Suprijanto (Bandung Institute of Technology)



Article Info

Publish Date
31 Jul 2019

Abstract

Introduction: The use of panoramic x-ray radiographs with analogue film negatives is still widely used. Contrast differences in the radiograph are determined by the level of light transmitted from the viewer to the film negative and visual perception of the radiologist, which can cause differences and errors of interpretation. This study was aimed to compare the quality of scanners produced by the transmission and reflection modes objectively with direct digital imaging standard. Methods: This study used a descriptive comparative design with purposive sampling method. Radiographic analysis was conducted towards 30 analogue radiographs of Radiology laboratory of Universitas Padjadjaran Dental Hospital. Digitisation was performed using a scanner with setting modes (reflection and transmission, 8-bit intensity resolution and spatial resolution of 800 dpi). Digitising the negative radiographs of analogue films into digital radiographs will get a range of percentage pixels. Histogram of radiographs with a percentage of pixels in the grey level range 0 - 64 exceeds 50%, including "under-exposed", in the grey level range 192 - 255 exceeding 50%, including "over-exposed". The evaluation was carried out to observe the radiograph exposure homogeneity by dividing the radiograph into 4 parts. Each part was calculated as the mean pixel value; then the standard deviation was searched for the four mean values (STDMI - standard deviation mean intensity) determined the homogeneity. Results: Digitising type of radiograph reflection was included under-exposed because the percentage of pixels in the grey level range 0 - 64 was 86.94%. STDMI consecutive reflection = 8.03, transmission = 18.05, direct digital imaging = 20.86. Conclusion: Digitisation with scanner transmission mode is the best result objectively because it approaches the quality value of direct digital imaging standard.Keywords: Objective quality, homogeneity, reflection, transmission

Copyrights © 2019






Journal Info

Abbrev

PJD

Publisher

Subject

Biochemistry, Genetics & Molecular Biology Dentistry Health Professions Immunology & microbiology Medicine & Pharmacology Public Health

Description

Padjadjaran Journal of Dentistry or known as PJD, is an English-language scientific periodicals published by the Faculty of Dentistry Universitas Padjadjaran thrice a year on every March, July and November. The submission process of manuscript is open throughout the year. All submitted manuscripts ...