Vitruvian : Jurnal Arsitektur, Bangunan, dan Lingkungan
Vol 9, No 1 (2019)

PENGARUH BUKAAN SAMPING (CLERESTORY) TERHADAP KUALITAS KENYAMANAN TERMAL PADA FOOD CARNIVAL, MALL AEON BSD

Tathia Edra Swasti (Universitas Mercu Buana)



Article Info

Publish Date
13 Nov 2019

Abstract

ABSTRAK Mall saat ini marak menggunakan clerestory sebagai salah satu upaya untuk penerangan alami pada siang hari. Namun, cahaya matahari pada sore hari (barat) akan menghasilkan cahaya matahari yang lebih panas dan silau dibandingkan cahaya matahari pada pagi hari (timur). Oleh karena itu, dengan pemakaian clerestory yang cukup besar pada bangunan, masalah panas tentu tak dapat dihindari. Begitu pula dengan glare yang berasal dari pantulan sinar matahari. Salah satu Mall yang menggunakan clerestory adalah Mall AEON BSD. Pengukuran suhu udara, temperatur efektif, kelembaban udara, kecepatan angin, PMV (Predicted Mean Vote) dan PPD (Predicted Percentage of Dissatisfied) dilaksanakan pada 4 waktu dengan 5 lokasi titik ukur yang memiliki kondisi berbeda untuk membuktikan bahwa clerestory dapat mempengaruhi kenyamanan termal. Disimpulkan bahwa titik 2 yaitu titik yang berdekatan dengan clerestory sisi kanan (ukurannya lebih kecil daripada clerestory sisi kiri) memiliki temperatur efektif dan kelembaban udara yang lebih rendah dari titik lain, dan kecepatan udara (dipengaruhi oleh hembusan AC) lebih tinggi dari titik lain. Responden merasa nyaman saat berada di titik tersebut.Titik paling nyaman menurut responden adalah titik 2 dengan TE rata-rata berkisar 27,4˚C, kelembaban udara rata-rata berkisar 52,2%, kecepatan udara rata-rata berkisar 0,15 m/s, PMV berkisar 0,5 dan PPD berkisar 12,7%. Dengan begitu semakin kecil ukuran skylight terbukti mempengaruhi kenyamanan termal dan membuat kenyamanan termal dapat tercapai. Kata Kunci: Mall, Clerestory, PMV, PPD, Kenyamanan Termal ABSTRACT Nowadays mall is decorated with clerestory as an effort to lighten naturally during the day. However, sunlight in the afternoon (west) will produce more sunlight and glare than sunlight in the morning (east). Therefore, with the use of a fairly large clerestory in buildings, the problem of heat certainly can not be avoided. Similarly, glare that comes from the reflection of sunlight. One of the malls that use clerestory is BSD AEON Mall. Measurement of air temperature, effective temperature, air humidity, wind speed, PMV (Predicted Mean Vote) and PPD (Predicted Percentage of Dissatisfied) carried out at 4 times within 5 measuring spots that have different conditions, proving that clerestory can affect thermal comfort. It was concluded that point 2, which is the point adjacent to the right side clerestory (smaller in size than the left side clerestory) has an effective temperature and lower air humidity than other points, and air velocity (affected by blowing AC) is higher than other points. Respondents felt comfortable when they were at that point. The most comfortable point according to respondents was point 2 with TE averaging around 27.4˚C, air humidity averaged 52.2%, the average air speed ranged from 0.15 m / s, PMV ranges from 0.5 and PPD ranges from 12.7%. Thus, the smaller size of the clerestory is affecting thermal comfort and thermal comfort can be achieved. Keywords: Mall, Clerestory, PMV, PPD, Thermal Comfort

Copyrights © 2019






Journal Info

Abbrev

virtuvian

Publisher

Subject

Civil Engineering, Building, Construction & Architecture Engineering Environmental Science

Description

Jurnal Ilmiah VITRUVIAN adalah jurnal yang mencakup artikel bidang ilmu arsitektur, bangunan, dan lingkungan. Jurnal ilmiah Vitruvian terbit secara berkala yaitu 3 (tiga) kali dalam setahun, yaitu pada bulan Oktober, Februari, dan Juni. Redaksi menerima tulisan ilmiah tentang hasil penelitian yang ...