Jurnal MEKANIKAL
Vol 2, No 2 (2011)

ANALISIS PENGARUH KUALITAS UAP RATA-RATA TERHADAP KOEFISIEN PERPINDAHAN PANAS RATA-RATA PADA PIPA KAPILER DI MESIN REFRIGERASI FOCUS 808

Basri, Basri (Unknown)



Article Info

Publish Date
28 Feb 2012

Abstract

This study aimed to obtain the influence of the average steam quality of heat transfer coefficient on average that occurs in the capillary tube and the relationship between average steam qualities with heat transfer coefficient on average in the capillary tube. This research was conducted at the University Engineering Laboratory Cooling Tadulako. Test methods used in the study is testing them experimentally. Data were collected by taking a direct test data on test equipment. Data were analyzed theoretically based on the experimental test data. The results of this study, namely that the refrigerant mass flow rate affect the heat transfer coefficient on average that occurs in the capillary tube is in the form of equation is hcm = 59569.78 xm^1.52

Copyrights © 2011