International Journal of Advanced Health Science and Technology
Vol. 1 No. 1 (2021): November

Nine Channel Temperature Data Logger in Measuring the Effectiveness of the Sterilization Process of Medical Instruments with Dry Sterilization

Nurul Al Istigho Farola (Department of Medical Electronics Engineering Technology, Poltekkes Kemenkes Surabaya)
Her Gumiwang (Department of Medical Electronics Engineering Technology, Poltekkes Kemenkes Surabaya)
Sumber Sumber (Department of Medical Electronics Engineering Technology, Poltekkes Kemenkes Surabaya)



Article Info

Publish Date
24 Oct 2021

Abstract

Measuring the temperature on the dry sterilizer is very necessary because the temperature inside the dry sterilizer has the possibility that the temperature is not the same as the temperature that has been set and is displayed on the display. If the temperature in the dry sterilizer does not match the standard setting temperature for the sterilization process, then the sterilization process is said to be imperfect The purpose of this study is to record and monitor whether the distributed temperature in the sterilization chamber corresponds to the setting temperature. The workings of the temperature data logger tool is that the type K thermocouple temperature sensor will detect the temperature which then enters the analog signal conditioning circuit which then enters the ATMegga 2560 which has been given a program and processed in such a way, then the temperature will be displayed on a 4x20 character LCD. Temperature measurement data will be saved to the SD Card every 10 seconds in the form of a TXT file. This research has been used to record 2 sterilizers and compared with the Madgetech OctTemp2000 data logger. Based on data measurements and comparisons, the average error was obtained at a temperature of 50ºC with the smallest error value of 0.7% and the largest value of 3.9%. At a temperature of 100ºC, the smallest error value is 1.6% and the largest is 10.5%. Then at a temperature of 120ºC the smallest error value is 0.0% and the largest is 8.5%. This research can be used to help analyze the distribution of temperature in a room. With these measurement results, it can be said that this study still has afairly high error value at several measurement points.

Copyrights © 2021






Journal Info

Abbrev

ijahst

Publisher

Subject

Electrical & Electronics Engineering Health Professions Nursing Public Health

Description

International Journal of Advanced Health Science and Technology (IJAHST) publishes peer-reviewed, original research and review articles in an open-access format. Accepted articles span the full extent of the Public Health, Environmental Health, Nursing, Oral and Dental Health, Midwifery, Nutrition, ...