cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota lhokseumawe,
Aceh
INDONESIA
Teras Jurnal
ISSN : -     EISSN : -     DOI : -
Core Subject : Social, Engineering,
Teras Jurnal is a journal that communicates the results of research within the scope of civil engineering and scientific development as well as aspects of practitioners. The process of manuscript submission is open throughout the year. All submitted manuscript will be screened with double-blind peer review and editorial review before they are accepted to publish. Teras Jurnal receives a manuscript from the following area below civil engineering science and development with the interdisciplinary and multidisciplinary approach:
Arjuna Subject : -
Articles 300 Documents
Efektivitas Penggunaan Difa SS Pada Soil-Bottom Ash Dan Soil Cement Dalam Meminimalkan Kerusakan Sub-Grade Jalan Sumiati sumiati; Mahmuda Mahmuda; Siswa Indra
TERAS JURNAL Vol 12, No 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.690

Abstract

Abstrak Salah satu penyebab kerusakan jalan adalah seringnya struktur perkerasan jalan terendam air saat musim hujan. Tanah lempung berplastisitas tinggi mempunyai sifat fisik dan teknik yang kurang baik jika digunakan sebagai lapisan tanah dasar (sub grade), karena mempunyai sifat kembang susut yang tinggi dan nilai CBR yang rendah jika terendam air. Stabilisasi menggunakan chemical additive dan limbah pabrik merupakan salah satu cara untuk memperbaiki sifat fisik dan teknik tanah, di mana akan memberikan hasil yang memadai jika komposisi campuran yang digunakan sesuai dan tepat. Oleh sebab itu akan diteliti efektifitas penggunaan aditif Difa SS pada Soil-Bottom ash dan Soil-Cement dengan melakukan pengujian CBR laboratorium unsoaked dan soaked. Hasil penelitian didapatkan bahwa penambahan Difa SS tidak memberikan peningkatan nilai CBR soaked pada Soil-bottom ash. Nilai CBR soaked Soil-Cement menunjukkan peningkatan dan lebih besar dibandingkan nilai CBR unsoaked sehingga Difa SS lebih efektif digunakan sebagai chemical additive pada Soil-Cement dalam usaha meminimalkan kerusakan jalan. Kata kunci: tanah-bottom ash, tanah-semen, Difa soil stabilizer.  Abstract One of the causes of road damage is that the pavement structure is often submerged in water during the rainy season. High plasticity clays soils have poor physical and technical properties when used as a subgrade layer, because they have high sweeling and shrinkage properties and low CBR values when submerged in water. Stabilization using chemical additives and factory waste is one way to improve the physical and engineering properties of the soil, which will give adequate results if the composition of the mixture used is appropriate and appropriate. Therefore, the effectiveness of the use of Difa SS additive in Soil-Bottom ash and Soil-Cement will be investigated by conducting unsoaked and soaked laboratory CBR testing. The results showed that the addition of Difa SS did not increase the soaked CBR value in soil-bottom ash. Soil-Cement soaked CBR value shows an increase and is greater than the unsoaked CBR value so that Difa SS is more effectively used as a chemical additive in Soil-Cement in an effort to minimize road damage. Keywords: soil-bottom ash, soil-cement, Difa soil stabilizer  
Pengaruh Abu Sekam Kayu Pada Nilai Unconfined Compression Strength Lempung Plastisitas Tinggi Terstabilisasi Semen Kapur Soewignjo Agus NUGROHO; Muhammad Faisal Al Ridho; Ferry Fatnanta
TERAS JURNAL Vol 12, No 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.688

Abstract

Abstrak Perbaikan lempung dengan semen, kapur, dan abu sekam (RHA) terbukti meningkatkan kuat geser dan daya dukung. Kandungan silika abu sekam kayu (ASK) hampir sama dengan RHA. Penelitian melihat pengaruh ASK pada lempung terstabilisasi semen dan kapur. Pengujian Tekan bebas (UCS) dilakukan untuk membandingkan nilai kuat tekan bebas (qu) lempung asli, lempung distabilisasi semen, dan kombinasi semen dan kapur dan/atau ASK. Sampel diuji pada empat kondisi. Hasil UCS tanpa pemeraman, nilai qu seragam. Pada kondisi tanpa pemeraman dan perendaman, nilai qu semua variasi relatif sama. Pada kondisi pemeraman dan tanpa perendaman, nilai qu berkisar 365 kPa sampai dengan 485 kPa untuk campuran dengan ASK dan kombinasi kapur dengan ASK. Penambahan kapur 10% meningkatkan nilai qu lebih 1100 kPa. Hasil UCS membuktikan, kapur lebih optimal meningkatkan nilai qu dibanding ASK. Penggantian kapur dengan ASK 4% sampai 6% meningkatkan nilai qu menjadi 485 kPa (rendaman) dan menjadi 475 kPa (tanpa rendaman). Kata kunci: Abu sekam Kayu, Kapur, lempung, semen, stabilisasi  Abstract Clay stabilized with cement, lime, and rice hush ash (RHA) has been increasing shear strength and bearing capacity. The silica content of wood husk ash (ASK) is almost the same as RHA. The study seen effect of ASK on clay-cement and lime. Unconfined Compression Strength (UCS) is performed and compare unconfining strength values (qu) of clay, clay-cement, and cement and lime and/or ASK. Sampel was tested on four conditions. UCS results without watering, uniform qu value. Conditions non-curing and soaked, the qu values of all variations are relatively the same. In curing and unsoaked conditions, qu values range from 365 kPa to 485 kPa for ASK and lime with ASK. Adding 10% lime increases qu value more than 1100 kPa. Stabilized with lime is more optimal than ASK to increase qu. Subtitution lime with ASK 4% to 6% increases qu value to 485 kPa (soaked) and to 475 kPa (unsoaked). Keywords: clay, cement, lime, sawdust ash, stabilization 
Analisis Kelayakan Ekonomi Bangunan Bronjong Tebing Sungai Dalam Upaya Pengendalian Erosi dian febrianti; Meylis Safriani; Zakia Zakia
TERAS JURNAL Vol 12, No 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.611

Abstract

Abstrak Studi Kelayakan sangat diperlukan oleh banyak kalangan seperti investor atau pemerintah. Salah satu program pemerintah untuk mensejahterakan masyarakat adalah dengan membangun fasilitas atau konstruksi yang dapat berpengaruh pada perekonomian masyarakat atau untuk keselamatan masyarakat, salah satunya yaitu bronjong. Pembangunan bronjong sebagai tebing sungai di Desa Padang Mancang, Kecamatan Kaway XVI, Kabupaten Aceh Barat diharapkan dapat memberikan keselamatan bagi warga yang tinggal di sekitar sungai dikarenakan pengikisan tebing sungai yang semakin parah. Pembangunan bronjong ini disarankan dapat menjadi bahan evaluasi bagi Dinas PU Pengairan untuk mengetahui tentang studi kelayakan ekonominya. Biaya modal yang dikeluarkan untuk pembangunan bronjong adalah sebesar Rp. 8.684.106.116,- dan biaya tahunan yang dikeluarkan (biaya operasional dan pemeliharaan) adalah sebesar Rp. 37.111.565,-. Manfaat yang diperoleh dengan adanya pembangunan bronjong didapat senilai Rp. 7.214.000.000,-. Studi Kelayakan Ekonomi Pada Pembangunan Bronjong Tebing Sungai bertujuan untuk mengetahui layak atau tidak proyek tersebut dijalankan dengan menggunakan metode NPV (Net Present Value), dan BEP (Break Even Point). Studi kelayakan ini menggunakan suku bunga 5% dan umur ekonomi bangunan 65 tahun. Hasil nilai NPV yang diperoleh sebesar Rp. 397.600.237,- atau NPV > 0 dan BEP terjadi pada tahun ke-60 bulan ke-6, sehingga waktu pengembalian modal kurang dari umur ekonomis proyek, yaitu 65 tahun. Kesimpulan dari hasil penelitian ini menunjukkan bahwa proyek pembangunan bronjong ini layak dilaksanakan dan dibangun untuk menghindari erosi pada tebing sungai. Kata kunci: Studi Kelayakan, bronjong, NPV, BEP.  Abstract A feasibility study is needed by many groups such as investors or the government. One of the government's programs for the welfare of the community is to build facilities or construction that can affect the economy of the community or for the safety of the community, one of which is the gabion. The construction of gabions as river cliffs in Padang Mancang Village, Kaway XVI District, West Aceh Regency is expected to provide safety for residents living around the river due to the increasingly severe erosion of river cliffs. The construction of gabions is suggested to be used as evaluation material for the Dinas PU Pengairan to find out about its economic feasibility study. The capital cost spent for the construction of gabions is Rp. 8,684,106,116, - and the annual cost incurred (operational and maintenance costs) is Rp. 37,111,565, -. The benefits obtained from the construction of gabion are valued at Rp. 7,214,000,000, -. The Economic Feasibility Study on the Development of the River Cliffs Gabion aims to determine whether the project is feasible or not to be carried out using the NPV (Net Present Value) and BEP (Break Even Point) methods. This feasibility study uses primary data, secondary data and assumptions to be used in the calculation of cash flow analysis. By using an interest rate of 5% and an economic age of 65 years, the NPV value obtained is Rp. 397,600,237, - and BEP occurs in the 60th year of the 6th month. The results of the three methods indicate that the gabion construction project is feasible to implement or build. Keywords: Feasibility Study, Gabion, NPV, BEP
Evaluasi Karakteristik Air Limbah Hasil Pengolahan Waste Stabilazion Pond di Kota Jakarta Yesaya Emeraldy Priutama; Ariyanti Sarwono; I Wayan Koko Suryawan
TERAS JURNAL Vol 12, No 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.657

Abstract

Abstrak Kota Jakarta merupakan kota metropolitan yang tidak lepas dari permasalahan lingkungan seperti adanya timbulan air limbah domestik. Air limbah domestik di kota Jakarta salah satunya diolah dengan waste stabilization pond (WSP) dan dengan sistem terpusat. Peningkatan jumlah pelayanan dan berubahnya karakteristik air limbah dapat mempengaruhi kinerja WSP. Tujuan dari studi ini adalah untuk mengevaluasi kinerja pengolahan air limbah dengan WSP di kota Jakarta. Adapun pengukuran dilakukan pada inlet dan outlet sistem WSP dan pengukuran berdasarkan parameter dari Biological Oxygen Demand (BOD5), Chemical Oxygen Demand (COD), Total Suspended Solids (TSS), pH dan amonia. Berdasarkan standar yang ditetapkan oleh pemerintah Indonesia, semua parameter tersebut telah memenuhi baku mutu. Efisiensi penyisihan parameter BOD, COD, TSS, amonia masing-masing adalah 96,22%; 88,66%, 96,19%, 98,62%. pH hasil pengolahan juga berada pada kondisi netral yaitu 6,5-8,5. Hasil dari pengolahan dengan WSP dapat dikatakan berjalan dengan baik dan diperlukan upaya untuk peningkatan yang berkelanjutan seperti perencanaan penggunaan ulang air hasil pengolahan. Kata kunci: waste stabilization pond, air limbah, efisiensi, parameter Abstract The city of Jakarta is a metropolitan city that cannot be separated from environmental problems such as the generation of domestic wastewater. One of the domestic wastewaters in the city of Jakarta is treated with a centralized system and treated with a waste stabilization pond (WSP). Increasing the number of services and changing wastewater characteristics can affect WSP performance. The purpose of this study is to evaluate the performance of wastewater treatment with WSP in the city of Jakarta. The measurements were carried out at the inlet and outlet of the WSP system and based on the parameters of Biological Oxygen Demand (BOD5), Chemical Oxygen Demand (COD), Total Suspended Solids (TSS), pH and Ammonia. Based on the standards set by the Indonesian government, all of these parameters have met the quality standards. Efficiency of removal of parameters BOD, COD, TSS, ammonia is 96.22% respectively; 88.66%, 96.19%, 98.62%. The pH of the processing is also in a neutral pH condition, namely 6.5-8.5. The results of the treatment with WSP can be said to be going well and efforts are needed for continuous improvement such as planning for the reuse of treated water. Keywords: waste stabilization pond, wastewater, efficiency, parameters
Analisis Daya Dukung Axial Pondasi Tiang Pancang Dengan Menggunakan Metode Kalendering Hasil Uji Pile Driving Analyzer Munirwansyah Munirwansyah; Reza Pahlevi Munirwan; Fauzan Mufid
TERAS JURNAL Vol 12, No 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.618

Abstract

Abstrak Pondasi adalah sebuah sistem rekayasa yang bekerja dengan meneruskan dan menopang beban serta beratnya sendiri ke tanah dasar (bearing layer) yang terletak di bawah pondasi. Jembatan Alue Lamteh merupakan jembatan yang berlokasi di Kecamatan Kuta Cot Glie, Kabupaten Aceh Besar berada pada koordinat 5°23’42,4” LU dan 95°29’35,9” BT. Jembatan ini masuk ke dalam Ruas Jalan Nasional Banda Aceh-Medan akan melayani pergerakan lalu lintas yang tergolong padat dengan banyak dilintasi oleh truk bermuatan besar. Tujuan dari penelitian ini adalah untuk menganalisis daya dukung dinamis pondasi tiang pancang melalui penggunaan data pengujian kalendering pada pekerjaan jembatan tersebut dengan menggunakan metode formula dinamik, ada tiga metode analisis yang digunakan, yaitu masing masing menggunakan metode Danish, metode AASHTO dan metode Gates dengan menggunakan data final set (s) capaian yang diizinkan untuk masing metode sebesar 24, 16 dan 12 mm.  Hasil analisis kapasitas daya dukung dinamik yang diperoleh dengan ketiga metode tersebut, yakni dengan menggunakan metode Danis. AASHTO dan Gates, masing-masing ditemukan daya dukung dinamik yang semakin meningkat dari 121,477 ton paling rendah, meningkat menjadi 241.047 ton dan menjadi 1267,051 ton sebagai daya dukung dinamis paling besar.   Kata kunci: Pondasi tiang pancang, pengujian kalendering, formula dinamis, final set.   Abstract The foundation is an engineering system that works by transmitting and supporting the load and its own weight into the subgrade (bearing layer) located below it. The Alue Lamteh Bridge is a bridge located in Kuta Cot Glie District, Aceh Besar Regency with coordinates at 5°23'42.4" North Latitude and 95°29'35.9" East Longitude. The bridge that enters the Banda Aceh-Medan National Road Section has a relatively heavy traffic movement with many large trucks being traversed. The purpose of this study was to analyze the dynamic bearing capacity of the pile foundation using calendaring test data on the Alue Lamteh Bridge widening project using the dynamic formula method, namely using the the Danis method, AASHTO method and the Gates method. Based on the results of the calculation of the carrying capacity of the carrying capacity using the the Danis method, AASHTO method and the Gates method, it was found that the largest dynamic carrying capacity value was using the Gates method, with the final set value 24, 16 and 12 mm respectively. of 121.477 ton, 241.047 ton and 1267,051 tons. while the large value of dynamic carrying capacity is using the Gates  method. Keywords: pile foundations, calendering test, dynamic formula, final set.  
Kinerja Campuran Asphalt Concrete Wearing Course Mengunakan Aspal Modifikasi Dengan Limbah Plastik Mukhlis Mukhlis; Fauna Adibroto; Syaifullah Ali; Ahmad Fauzi; Ivan Padilah
TERAS JURNAL Vol 12, No 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.648

Abstract

 Abstrak  Perkerasan jalan terutama pada perkerasan lentur sering mengalami kerusakan yang lebih cepat akibat beban muatan kendaraan. Penggunaan bahan tambah (additive) menjadi salah satu alternatif yang digunakan untuk mendapatkan kualitas lapis perkerasan yang baik. Penelitian ini bertujuan untuk mendapatkan nilai Kadar Aspal Optimum (KAO) dan mendapatkan kinerja VIM, VMA dan VFA campuran lapisan AC-WC dengan penambahan limbah plastik High Density Polyethylene (HDPE). Metode yang digunakan pada penelitian ini mengacu pada Spesifikasi Teknis Bina Marga 2018 Revisi 2 Divisi 6. nilai KAO dengan metode marshall sebesar 6,45% pada variasi 0% penambahan limbah plastik, 6,3% pada variasi 1% penambahan limbah plastik, 6,25% pada variasi 1,5% penambahan limbah plastik dan 6,2% pada variasi 2% penambahan limbah plastik. Berdasarkan hasil pengujian laboratorium nilai KAO Marshall yang didapatkan semakin menurun dengan penambahan limbah plastik dan penambahan limbah plastik 2% merupakan kadar terbaik yang dapat digunakan dalam campuran beraspal karena memiliki nilai VIM dan VMA yang rendah dan nilai VFA yang tinggi. Kata kunci: 1, Aspal 2, AC-WC 3, Limbah Plastik 4, HDPE 5 Marshall     Abstract   Road pavements, especially flexible pavements, often experience faster damage due to vehicle loads. The use of additives is one of the alternatives used to get a good quality pavement layer. This study aims to obtain the value of Optimum Asphalt Content (KAO) and to obtain the performance of VIM, VMA and VFA of a mixture of AC-WC layers with the addition of High Density Polyethylene (HDPE) plastic waste. The method used in this study refers to the Technical Specifications of Bina Marga 2018 Revision 2 Division 6. the KAO value with the Marshall method is 6.45% at 0% variation of addition of plastic waste, 6.3% to variation of 1% addition of plastic waste, 6, 25% in the 1.5% variation of the addition of plastic waste and 6.2% in the 2% variation of the addition of plastic waste. Based on the results of laboratory testing, the value of KAO Marshall obtained decreases with the addition of plastic waste and the addition of 2% plastic waste is the best level that can be used in asphalt mixtures because it has low VIM and VMA values and high VFA values.   Keywords: 1, Asphalt 2, AC-WC 3, Plastic Waste 4, HDPE 5 Marshall
Model NRECA Untuk Prediksi Ketersediaan Air di Daerah Irigasi Citanduy Kota Tasikmalaya Sulwan Permana; Adi Susetyaningsih
TERAS JURNAL Vol 12, No 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.693

Abstract

Abstrak Sektor pertanian masih merupakan primadona masyarakat dan dijadikan sebagai pekerjaan dalam menunjang kehidupan, meskipun banyak kawasan pertanian yang beralih fungsi menjadi pemukiman terutama di perkotaan. Hampir setiap tahun, luas panen mengalami penurunan. Untuk mengantisipasi hal tersebut, pemerintah dan pemerintah daerah telah banyak membangun infrastruktur keairan, terutama bendung dan bendungan. Daerah irigasi Citanduy dengan luas layanan 427 hektar merupakan salah satu daerah irigasi di Kota Tasikmalaya, sehingga sangat rentan terhadap alih fungsi lahan persawahan menjadi pemukiman. Ketersediaan air sangat penting dalam pemenuhan areal pertanian. Penelitian ini dilakukan untuk mengetahui debit andalan di DAS Citanduy-Sirnagalih seluas 474,65 km2. Terdapat 2 pos curah hujan yaitu Cigede dan Tejakalapa selama sepuluh tahun dari tahun 2009 hingga 2018. Curah hujan rata-rata bulanan dihitung dengan metode Thiessen dengan proporsi luas pengaruh adalah 0,4 dan 0,6. Evapotranspirasi dihitung menggunakan metode Penman-Monteith, dan pemodelan debit menggunakan metode NRECA. Pos duga air Asta-Cikunir digunakan sebagai acuan dalam menentukan parameter kalibrasi yaitu PSUB, GFW, dan tampungan air tanah awal dengan nilai 0,8, 0,29: 100, serta nilai NSE 0,719. Debit andalan Q80 adalah 17,4 m3/s. Debit andalan adalah ketersediaan air di daerah irigasi Citanduy. Berdasarkan debit andalan ini, musim tanam I dan II masih dapat dilakukan secara bersamaan. Kata kunci: debit andalan, kalibrasi, NSE, sungai Citanduy   Abstract The agricultural sector is still the prima donna of the community and is used as a job to support life. However, many agricultural areas have been converted into settlements, especially in urban areas. Almost every year, the harvested area has decreased. To anticipate this, the government and local governments have built a lot of water infrastructure, especially weirs and dams. The Citanduy irrigation area with a service area of 427 hectares is one of the irrigation areas in the City of Tasikmalaya, so it is very vulnerable to the conversion of rice fields into settlements. The availability of water is crucial in fulfilling agricultural areas. This research was conducted to determine the mainstay discharge in the Citanduy-Sirnagalih watershed covering an area of 474.65 km2. There are two rainfall posts, namely Cigede and Tejakalapa, for ten years from 2009 to 2018. The average monthly rainfall is calculated by the Thiessen method, with the proportion of the area of influence being 0.4 and 0.6. Evapotranspiration was calculated using the Penman-Monteith method and discharge modeling using the NRECA method. The Asta-Cikunir water gauge post is used as a reference in determining calibration parameters, namely PSUB, GFW, and initial groundwater reservoirs with values of 0.8, 0.29: 100, and NSE values of 0.719. The Q80's dependable flow is 17.4 m3/s. The mainstay of debit is the availability of water in the Citanduy irrigation area. Based on this reliable discharge, planting seasons I and II can still be carried out simultaneously. Keywords: dependable flow, calibration, NSE, Citanduy river 
Analisis Kelayakan Dimensi Landasan Pacu Bandar Udara Torea di Kabupaten Fakfak Propinsi Papua Barat Muhammad Yunus
TERAS JURNAL Vol 12, No 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.600

Abstract

Abstrak Perkembangan moda sektor transportasi khususnya moda transportasi udara dewasa ini mengalami perkembangan yang sangat signifikan. Hal ini disebabkan moda transportasi udara berupa pesawat terbang dapat membuat manusia berpindah tempat dengan sangat cepat, tidak seperti moda transportasi darat maupun laut yang memerlukan waktu yang lebih lama. Sehubungan hal tersebut maka dibutuhkan bandar udara yang memenuhi persyaratan dari segi keamanan dan keselamatan penerbangan. Tujuan penelitian untuk menganalisis dimensi landasan pacu (runway) serta mengevaluasi kelayakan dimensi landasan pacu (runway) Bandar Udara Torea di Kabupaten Fakfak Propinsi Papua Barat. Dari hasil penelitian yang dilakukan diperoleh dimensi panjang landasan pacu Bandar Udara Torea telah memenuhi persyaratan minimum yang ditetapkan oleh International Civil Aviation Organization (ICAO) tahun 2016 dengan panjang landasan pacu Bandar Udara Torea sepanjang 1201,8 m tetapi dari segi persyaratan untuk jenis pesawat ATR 72-600 belum memenuhi persyaratan sedangkan untuk standar dimensi lebar landasan lacu dan lebar bahu landasan pacu Bandar Udara Torea sesuai Peraturan Kementerian Perhubungan Direktorat Jenderal Perhubungan Udara Nomor : KP 39 Tahun 2015 tentang Standar Teknis dan Operasi Peraturan Keselamatan Penerbangan Sipil. Kata kunci: Moda transportasi, landasan pacu, bandar udara, pesawat ATR 72-600.   Abstract The development of transportation sector modes, especially air transportation modes, is currently experiencing a very significant development. This is because the mode of air transportation in the form of airplanes can make people move very quickly, unlike land and sea transportation modes which require a longer time. In this regard, an airport that meets the requirements in terms of flight security and safety is needed. The aims of the study was to analyze the dimensions of the runway and evaluate the feasibility of the runway dimensions at Torea Airport in Fakfak Regency, West Papua Province. From the results of the research conducted, it was found that the dimensions of the runway length of Torea Airport have met the minimum requirements set by the International Civil Aviation Organization (ICAO) in 2016 with a runway length of 1201.8 m Torea Airport but in terms of requirements for the type of aircraft ATR 72- 600 does not meet the requirements while for the standard dimensions of the runway width and the width of the runway shoulder of Torea Airport according to the Regulation of the Ministry of Transportation of the Directorate General of Civil Aviation Number: KP 39 of 2015 concerning Technical and Operational Standards of Civil Aviation Safety Regulations. Keywords: Modes of transportation, runway, airport, ATR 72-600 aircraft  
Studi Numerikal Grup Fondasi Elevated Pile Cap Pada Tanah Pasir Fathia Handayani Kamal; Widjojo Adi Prakoso; Mulia Orientilize
TERAS JURNAL Vol 12, No 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.682

Abstract

Abstrak Elevated Pile Cap (EPC) merupakan fondasi tertanam sebagian di dalam tanah yang rentan terhadap beban gempa karena momen fleksural yang terjadi lebih besar daripada jenis fondasi yang tertanam sepenuhnya. Studi numerikal dengan metode BNWF menggunakan aplikasi OpenSees berbasis eksperimen yang dilakukan peneliti lain dilakukan untuk mempelajari perilaku non-linear fondasi di tanah pasir. Fondasi berkonfigurasi tunggal, 2x2, dan 2x3 dimodelkan dan divalidasikan terhadap penelitian tersebut. Variasi nilai densitas pasir dan pemberian nilai p-multiplier yang berbeda diperhitungkan per baris fondasi grup. Analisis pushover monotonik dilakukan untuk mengetahui perilaku ineastik fondasi. Semua model membentuk sendi plastis pada sambungan dan di bawah tanah pada tiang leading row. Perbandingan respons individu tiap tiang dengan respons rata-rata fondasi per tiang digunakan untuk mengetahui distribusi gaya pada fondasi yang dipengaruhi oleh nilai p-multiplier. Kuat geser tanah divariasikan untuk mengetahui keelastisitasan tanah saat pembebanan di titik tertentu, di mana semakin padat tanah maka semakin cepat fase plastis tercapai. Secara keseluruhan, variasi kepadatan tanah dan nilai p-multiplier mempengaruhi perilaku inelastis fondasi. Kata kunci: EPC, fondasi grup, sendi plastis, p-multiplier, analisis pushover                                                Abstract Elevated Pile Cap (EPC), a partially-embedded foundation, is vulnerable under seismic loadings since it suffers more flexural moment than average foundations. A BNWF numerical study was performed using OpenSees based on an experiment conducted in China. The 1x1, 2x2, and 2x3 rectangular EPC groups were modeled and validated by the test result. Each model is embedded in sand with a varied density and A different value of p-multiplier for each pile rows was considered. Monotonic pushover analysis was performed, and its inelastic behavior were investigated. All models suffer double plastic hinges on the leading row, located in connection and underground, depending on the soil density. The ratio of each pile row response to the average pile group response is an indicator to examine the forces distribution, influenced by p-multiplier only. The soil shear strength was investigated to observe the elasticity of soil when it reach its yield, ultimate, and the formed of plastic hinges. The p-multiplier and varied soil density affects the soil strength for pile rows, the denser the soil, the faster it reaches its plastic state. Overall, both p-multiplier and soil density affect inelastic behavior of foundations. Keywords: EPC, group foundation, plastic hinge, p-multiplier, pushover analysis
Analisis Life Cycle Cost Pada Proyek Jembatan Merah Putih di Kota Ambon Dengan Pendekatan Nilai Ekuivalensi Hans Dermawan; Christy Vianty Patty
TERAS JURNAL Vol 12, No 2 (2022): Volume 12 Nomor 2, September 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i2.769

Abstract

Abstrak Pembangunan infrastruktur yang sangat pesat menjadi hal utama bagi pemerintah di Kota Ambon dalam meningkatkan pertumbuhan ekonomi masyarakat. Salah satu infrastruktur yang menjadi prioritas pemerintah setempat yaitu Jembatan Merah Putih di Kota Ambon yang dibangun sejak tahun 2011. Penelitian ini bertujuan untuk mengidentifikasi komponen biaya proyek Jembatan Merah Putih, seperti: biaya awal, biaya pengoperasian dan biaya pemeliharaan selama tahun 2017 sampai 2020 serta mengevaluasi biaya pemeliharaan jembatan selama 100 tahun mendatang. Metode life cycle cost dengan pendekatan nilai ekuivalensi sebagai metode penelitian. Hasil dari penelitian ini untuk total life cycle cost dari Jembatan Merah Putih yaitu biaya awal sebesar Rp731.578.760.000 (96,26%), biaya operasional sebesar Rp2.338.600.000 (0,31%) dan biaya pemeliharaan sebesar Rp27.138.274.698 (3,43%), sehingga diperoleh total biaya life cycle cost sebesar Rp761.055.634.698. Komponen biaya pemeliharaan struktur sebagai komponen biaya tertinggi yang perlu dipertimbangkan agar pembiayaan terhadap pemeliharaan Jembatan Merah Putih di Kota Ambon dapat terjaga. Kata kunci: jembatan, life cycle cost, nilai ekuivalensi   Abstract The rapid development of infrastructure is the main thing for the government in Ambon City to increase the community's economic growth. One of the infrastructures that are a priority for the local government is the Merah Putih Bridge in Ambon, which was built in 2011. This study aims to identify cost components, such as initial costs, operating costs, and maintenance costs from 2017 to 2020, and evaluate bridge maintenance costs for the next 100 years. The life cycle cost method with an equivalence value approach as a research method. The results of this study for the total life cycle cost of the Merah Putih Bridge are initial costs of Rp731,578,760,000 (96.26%), operational costs of Rp2,338,600,000 (0.31%) and maintenance costs of Rp27,138,274,698 (3.43%), so that the total life cycle costs of Rp761,055,634,698 were obtained. The structural maintenance cost component is the highest cost component that needs to be considered so that the financing for the maintenance of the Merah Putih Bridge in Ambon city can be maintained. Keywords: bridge, life cycle cost, equivalence value