cover
Contact Name
muchamad arif budiyanto
Contact Email
arifbudiyanto.sipil@gmail.com
Phone
+628122522081
Journal Mail Official
arifbudiyanto.sipil@gmail.com
Editorial Address
Jl. Perintis Kemerdekaan, Gambiran, Pandeyan Kecamatan Umbulharjo, Yogyakarta, Daerah Istimewa Yogyakarta 55161 Telp : (0274) 372274
Location
Kota yogyakarta,
Daerah istimewa yogyakarta
INDONESIA
Civil Engineering and Technology Journal
ISSN : 27984869     EISSN : 27984060     DOI : https://doi.org/10.47200/civetech.v3i1
CivETech: Civil Engineering and Technology Journal pertama kali diterbitkan pada Februari 2019 yang diterbitkan oleh Fakultas Teknik Universitas Cokroaminoto Yogyakarta (FT UCY). CivETech diterbitkan 2 (dua) kali setahun pada bulan Februari dan Agustus, diterbitkan secara online dan akses terbuka dengan Elektronik dengan P-ISSN 2798-4869 dan E-ISSN 2798-4060. CivETech berfokus pada bidang teknik sipil, termasuk rekayasa struktur dan bahan bangunan, manajemen dan teknologi konstruksi, mekanika tanah dan geoteknik, perencanaan pondasi, perencanaan dan manajemen transportasi, rekayasa dan pengembangan jalan raya, rekayasa teknik dan manajemen sumber daya air, manajemen pengelolaan air bersih dan limbah, dinamika pantai, teknologi gempa bumi dan tsunami.
Articles 60 Documents
Studi Kelayakan Biaya Dan Teknik Pada Pengembangan Kavling Perumahan Di Desa Bangunjiwo Kecamatan Kasihan Kabupaten Bantul Provinsi D.I Yogyakarta muhamad Arifin; Fajar Purwoko; Subarno Subarno
CivETech Vol 4 No 1 (2022): CivETech
Publisher : Fakultas Teknik Universitas Cokroaminoto Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47200/civetech.v4i1.1105

Abstract

Investasi properti menjamur di Indonesia dalam beberapa tahun belakangan, sebab nilai investasi kian waktu kian meningkat. Peningkatan nilai investasi selaras dengan jumlah permintaan yang meningkat, yang disebabkan oleh peningkatan jumlah penduduk. Pertumbuhan penduduk di kabupaten Bantul mengalami peningkatan sekitar 1,14% dalam satu tahun terakhir, melihat data tersebut ada sebuah peluang untuk dilakukannya investasi perumahan. Dalam proses analisa penelitian dibagi dalam beberapa tahap, diantaranya pengumpulan data primer dan sekunder, kemudian analisis ekonomi. Luas lahan yang digunakan 805 m2 direncanakan dengan total 8 unit rumah dengan type 45/77 sebanyak 2 unit dan type 55/88 sebanyak 6 unit. Berdasarkan hasil perhitungan, NPV sebesar (=) Rp 1.086.000.000,00, PP terjadi pada tahun pertama, IRR bernilai 33%, PI sebesar 1,67 > 1. Berdasarkan hasil tersebut dapat disimpulkan bahwa investasi di Pengembangan Kavling Perumahan di Desa Bangunjiwo Kecamatan Kasihan Kabupaten Bantul layak dilakukan.
Evaluasi Properti Marshall Terhadap Mutu Aspal Beton Lapangan Pada Runway Bandara Yogyakarta International Airport Suryanto Suryanto; Nurokhman Nurokhman
CivETech Vol 4 No 1 (2022): CivETech
Publisher : Fakultas Teknik Universitas Cokroaminoto Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47200/civetech.v4i1.1106

Abstract

Pada pekerjaan runway Bandara YIA dengan lapis perkerasan aspal beton ACBC dan lapisan aus ACWC merupakan konstruksi penting dalam mendukung beban pesawat untuk landing dan take off yang harus sesuai spesifikasi yang telah ditentukan. Dalam penentuan kadar aspal yang akan berpengaruh pada kepadatan lapisan ACBC dan lapisan ACWC telah dilakukan pengujian Marshall di laboratorium untuk mendapatkan formula yang tepat agar hubungan kadar aspal dan kepadatan lapisan laston sesuai yang diharapkan. Studi bertujuan mengetahui hasil parameter pepada ngujian Marshall lapisan ACBC dan lapisan ACWC di laboratorium, menganalisis hasil pengujian pekerjaan lapisan perkerasan aspal beton sesuai dengan standar spesifikasi teknis yang ditentukan, menganalisis pengaruh property penguian Marshall terhadap tebal lapisan coredrill, mutu kadar aspal dan kepadatan laston. Metode penelitian dengan sumber data primer pengamatan langsung di laboratorium PT. ADP dan laboratorium Politeknik Negeri Semarang dan lokasi proyek serta data sekunder laporan pengujian runway pada tahap job mix design, trial dan penghamparan di lokasi runway Bandara YIA dari PT. Angkasa Pura dengan kontraktor PT. PP KSO dan Konsultan PMCC PT. Tata Guna Patria. Dari hasil penelitian pelaksanaan pekerjaan lapisan runway sebagai landasan pacu pesawat di Bandara YIA dilakukan sesuai procedure dan spesifikasi yang tercantum pada Rencan Kerja dan Syarat-syarat serta peraturan lain yang berlaku. Bahan laston berupa aspal penetration grade 60-70, agregat quarry Kokap Kulon Progo mempunyai abrasi 12,52%, kekekalan 0,14%, nilai setara pasit 98,17%, partikel pipih 9,71%, dan pada pasir kadar lumpur 1,83% memenuhi persyaratan. Hasil pengujian trial mix design dengan kadar aspal 4,5% sampai dengan 6,5% berat jenis aspal 1,03 gr/cm3 diperoleh penyerapan aspal 0,893% dan kadar aspal efektif aspal 4,757%. Properti Marshall AC-WC diproleh Stabilitas 1400 kg, flow 3,30 mm, VIM 4,00 %, VFB 77,0 %, Berat Jenis Campuran 2,280 gr/ml, VMA 17,40 %, Kadar Aspal Effektif 5,198%, Kadar dan Aspal optimim 6,11%. Dari hasil pengujian ketebalan ACWC dengan core drill pada badan runway menunjukkan tebal 5,20 - 7,40 cm telah memenuhi syarat batas tebal ACWC yaitu 4,70. Untuk ACBC yang dilakukan dalam 2 layer menunjukkan tebal rata-rata layer 1 sebesara 8,2 cm dan tebal rata-rata layer 2 sebesar 6,4 cm seingga tebal total lapisan ACBC sebsar 14,6 cm yang berada pada minimum 12,6 cm dan hasil pengujian dengan coredrill tercapai kepadatan 99,3%.
PENGARUH PENAMBAHAN LIMBAH BUBUT BESI TERHADAP KUAT TEKAN BETON Erlina Erlina; Muhammad Ryan Iskandar; Nazira Aulia Pohan
CivETech Vol 4 No 2 (2022): CivETech
Publisher : Fakultas Teknik Universitas Cokroaminoto Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47200/civetech.v4i2.1293

Abstract

Beton digunakan sebagai bahan baku kontruksi dalam proyek bangunan. Karakteristik yang dimiliki beton sangat dipengaruhi oleh bahan-bahan yang terkandung didalam campuran dan cara pengolahannya. Penelitian ini bertujuan untuk mengetahui kuat tekan beton dengan memanfaatkan limbah bubut besi sebagai bahan tambahan sebesar 0% , 5% , 10%. Penelitian dilakukan dengan membandingkan pengaruh kuat tekan, kuat lentur beton dengan serat limbah bubut besi. Pengujian yang dilaksanakan di laboratorium selanjutnya dihitung dengan formula dan prosedur yang telah ditentukan untuk menentukan besarnya kuat tekan beton dan kuat lentur. hasil pengujian dan perhitungan diperoleh nilai daya serap air berkisar 2,909% sampai 3,787% dan nilai berat jenis beton sebesar 2,29 gr/cm³ sampai 2,32 gr/cm³. Hasil penelitian menunjukkan pengujian kuat tekan beton diketahui nilai kuat tekan beton normal sebesar 22,64 MPa, kuat tekan beton dengan 5% limbah bubut besi sebesar 23,39 MPa dan kuat tekan beton dengan tambahan 10% limbah bubut besi sebesar 26,41 MPa. Semakin besar persentase penambahan limbah bubut besi, semakin besar juga kuat tekan beton tersebut.
PERBANDINGAN DAYA DUKUNG DAN PENURUNAN TANAH PADA PONDASI DANGKAL BERDASARKAN DATA SPT DAN CPT Hery Kristyanto; Fajar Purwoko; Lili Wijayanti
CivETech Vol 4 No 2 (2022): CivETech
Publisher : Fakultas Teknik Universitas Cokroaminoto Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47200/civetech.v4i2.1300

Abstract

Pondasi merupakan komponen struktur yang berfungsi untuk meneruskan beban bangunan ke lapisan tanah di bawahnya tanpa adanya resiko kelongsoran geser atau terjadinya penurunan yang melampaui batas yang diijinkan. Kapasitas daya dukung tanah adalah kemampuan tanah dalam mendukung beban pondasi yang bekerja di atasnya. Penelitian ini bertujuan untuk mengetahui besarnya kapasitas daya dukung dan penurunan tanah pada pondasi dangkal berdasarkan hasil Standar Penetration Test (SPT) dan Cone Penetration Test (CPT), pada elevasi pondasi -1 meter dan -2 meter. Hasil perhitungan memperlihatkan bahwa kapasitas daya dukung tanah pada pondasi dangkal berdasarkan data SPT pada titik BH1 elevasi -1 meter dan -2 meter berturut-turut yaitu sebesar 90 kN/m2 dan 140 kN/m2 dengan penurunan tanah berturut-turut sebesar 0,435 inch dan 0,447 inch. Besar kapasitas daya dukung tanah pada pondasi dangkal berdasarkan data CPT pada titik SB1 elevasi -1 meter dan -2 meter berturut-turut sebesar 437,380 kN/m2 dan 596,244 kN/m2 dengan penurunan tanah berturut-turut sebesar 0,796 inch dan 0,318 inch, sedangkan pada titik SB2 elevasi -1 meter dan elevasi -2 meter daya dukung tanah berturut-turut sebesar 334,410 kN/m2 dan 502,101 kN/m2 dengan penurunan tanah sebesar 1,082 inch dan 0,465 inch. Kapasitas daya dukung tanah berdasarkan hasil CPT memperlihatkan nilai yang lebih besar dibandingkan hasil SPT, dan keduanya menunjukan hasil penurunan tanah yang hampir sama pada kedalaman -2 meter.
OPTIMALISASI KAPASITAS VOLUME TAMPUNGAN EMBUNG TUGU KABUPATEN KEBUMEN Muchamad Arif Budiyanto; Indra Suharyanto
CivETech Vol 4 No 2 (2022): CivETech
Publisher : Fakultas Teknik Universitas Cokroaminoto Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47200/civetech.v4i2.1301

Abstract

Kebumen District area has a tendency to rainfall which is uneven in rainfall throughout the year, namely the rainy season where there is surplus water, whereas the dry season results in deficit of water. Tugu village one if village in Kebumen, Central Java, Indonesia has a location that has the potential to be developed into a reservoir. The purpose of this study was to determine the optimal storage capacity of the reservoir. Based on the Guide to Small Pond Design Criteria for Semi-Dry Areas in Indonesia in 1997 the capacity of the reservoir is carried out by taking into account water needs, water availability and topography. After calculating, it is found that the storage capacity based on water needs (Vn) is 48,935.70 m3. Based on the analysis of water availability (potential) during the rainy season (Vh), the volume of water that can be accommodated is 7,500.00 m3. The design capacity of a reservoir (Vd), which is equal to Vd = 7,500.00 m3 with height of dam 3.00 m.
KAJIAN PENENTUAN LAJU EROSI TAHUNAN, PENETAPAN STATUS TINGKAT BAHAYA EROSI DAN MUATAN SEDIMEN DI DAS BUNTUNG, DAS DOHO DAN DAS KEDUNGJAMBAL, KABUPATEN SUKOHARJO, JAWA TENGAH Muhamad Arifin; Rajib Khafif Arruzzi; Evita Pramudianti
CivETech Vol 4 No 2 (2022): CivETech
Publisher : Fakultas Teknik Universitas Cokroaminoto Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47200/civetech.v4i2.1302

Abstract

Banjir yang sering terjadi di wilayah Kabupaten Sukoharjo khususnya di sekitar Sungai Doho, Sungai Buntung, dan Sungai Kedungjambal disebabkan kapasitas sungai yang sudah tidak bisa menampung limpasan air hujan. Salah satu penyebab dari penyempitan kapasitas sungai adalah faktor erosi dan sedimentasi yang terjadi di ketiga DAS tersebut. Untuk mengetahui seberapa besar laju erosi tahunan, status tingkat bahaya erosi, dan muatan sedimen yang terjadi di ketiga DAS tersebut perlu dilakukan kajian yang tepat dan komprehensif. Dalam kajian ini digunakan metode USLE untuk melakukan analisis terhadap laju erosi dan muatan sedimen yang terjadi. Hasil dari analisis di ketiga DAS tersebut diperoleh bahwa DAS Buntung laju erosi tahunan sebesar 262,096 Ton/Ha/Th dan tingkat bahaya erosi termasuk dalam kelas sangat ringan, sedangkan muatan sedimen sebesar 13.515,68 m3/Th. DAS Doho diperoleh laju erosi sebesar 94,139 Ton/Ha/Th dengan tingkat bahaya erosi dominan masuk kelas sangat ringan, dan muatan sedimen sebesar 4.073,68 m3/Th. Sedangkan untuk DAS Kedungjambal diperoleh laju erosi sebesar 177,88 Ton/Ha/Th dengan tingkat bahaya erosi dominan masuk kelas sangat ringan dan memiliki muatan sedimen sebesar 7.549,61 m3/Th.
STUDI KADAR ASPAL, KEPADATAN DAN TEBAL LAPISAN LASTON AC-BC HASIL COREDRILL PADA RUAS JALAN KSPN BOROBUDUR Nurokhman Nurokhman; Suryanto Suryanto; Akhmad Rizki Tsany
CivETech Vol 4 No 2 (2022): CivETech
Publisher : Fakultas Teknik Universitas Cokroaminoto Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47200/civetech.v4i2.1303

Abstract

Pelaksanaan rehabilitasi Ruas jalan KSPN Borobudur sebagai akses utama destinasi wisata Candi Borobudur dan sekitarnya menjadikan jalan ini sangat vital yang harus dimonitoring aspek kualitas dan target ketepatan waktu. Pada pekerjaan mayor rehabilitasi Jalan KSPN Borobudur, konstruksi jalan dengan lapis perkerasan aspal beton AC-BC telah ditetapkan spesifikasi yang harus dilakukan. Studi bertujuan mengetahui kualitas setiap tahapan pekerjaan apsal beton di laboratorium dan lapangan dan menganalisis hasil pengujian pekerjaan lapisan perkerasan aspal beton sesuai dengan standar spesifikasi teknis Bina Marga. Dari hasil penelitian pekerjaan mayor terdapat pengaruh kadar aspal beton AC-BC campuran 5,70% terhadap property Marshall seperti penyerapan aspal 0,79 % < 1,2 %, rongga dalam campuran (VMM) Marshall 4,4 % (batasan 3-5 %), rongga dalam mineral Agg (VMA) Marshall 15,6 % > 14% , rongga terisi aspal (VFB) Marshall 72,0% > 65% , stabilitas Marshall 920 kg > 800 kg, kepadatan 2,342 ton/m2 dan quantient Marshall 310 kg > 250 kg/mm. Pengaruh pemadatan dengan passing 2-12 dengan kepadatan rata-rata 98,17%, untuk passing 2-14 kepadatannya 98,47% dan untuk passing 2-16 kepadatannya 98,60% yang semuanya dalam syarat kepadatan menurut Spesifikasi Umum Bina Marga Tahun 2010 adalah 98% sehingga hasil kepadatan lapangan tersebut memenuhi syarat. Untuk nilai berat jenis laboratorium didapat dari Job Mix Formula (JMF) dengan cara yang sama. Dari pengujian lapangan core drill ketebalan Laston AC-BC rata-rata 6,6 cm minimum 5,8 cm memenuhi syarat batas minimum 5,6 cm.
ANALISIS STRUKTUR ATAS RANGKA BAJA PADA BANGUNAN INDUSTRI PETERNAKAN UNGGAS Singgih Subagyo; Nurokhman Nurokhman; Indra Suharyanto
CivETech Vol 4 No 2 (2022): CivETech
Publisher : Fakultas Teknik Universitas Cokroaminoto Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47200/civetech.v4i2.1304

Abstract

Dalam pembangunan industri peternakan unggas, umumnya struktur bangunan yang digunakan adalah struktur baja. Jarak antar kolom dapat dibuat pada lebar yang cukup besar, hal ini karena kebutuhan jarak antar kolom yang jauh sedangkan atap biasanya merupakan atap metal yang ringan seperti galvalume atau sejenisnya. Material baja juga memeiliki kekakuan sekitar 10x lipat dari kekakuan beton sehingga jika digunakan strutkur ukurannya bisa lebih kecil dan ringan. Untuk bentang antar kolom yang tidak terlalu panjang misal 10 m, bisa digunakan baja profil biasa, sedangkan jika lebih panjang dapat digunakan castileted, yaitu profil baja misal baja I/WF (wide flange). Pada studi kasus perencanaan bangunan industri PT. Widodo Makmur Unggas umumnya digunakan konstruksi baja gabler dengan bentang 18 m dan penutup atap baja metal. Pemilihan konstruksi diharapkan cepat pelaksanaannya dengan tetap memperhatikan aspek kekuatan dan efisiensi. Tujuan penelitian untuk mengetahui struktur atas rangka baja sebagai model banguanan industri untuk fungsi usaha peternakan ungags dan menganalisis hasil perencanaan struktur atas dengan mempertimbangkan terhadap tegangan-tegangan yang diijinkan. Dalam perencanaan bangunan industry dengan konstruksi baja perlu dipertimbangkan kominasi pembebanan yang dominan besar untuk menentukan hasil gaya-gaya batang dalam menentukan dimensi elemen struktur. Pembebanan dengan memperhitungkan kombinasi gaya batang maksimum pada elemen ikatan angin, kolom, pengaku balok, pengaku kolom, dan pelat dasar kolom. Konstruksi baja dengan bentang portal 18 m dipilih rangka atap dicoba profil C 125.50.20.3,2 mm, profil balok baja kran C32, profil kolom baja WF 450.300.11.18 mm. Hasil analisis pemilihan profil perencanaan pembangunan gedung industry telah memenuhi persyaratan dibawah tegangan ijin dalam menahan gaya tarik, gaya tekan dan momen lentur.
PERBANDINGAN MUTU BETON K-250 DENGAN MENGGUNAKAN PASIR PUTIH DARI DARAT DAN PASIR BEKAS GALIAN BAUKSIT Erlina Erlina; Hery Kristiyanto; Muhamad Defan Zulfikar
CivETech Vol 5 No 1 (2023): CivETech
Publisher : Fakultas Teknik Universitas Cokroaminoto Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47200/civetech.v5i1.1551

Abstract

Pasir merupakan salah satu bahan yang digunakan untuk campuran beton, adapun fungsi dari pasir dalam adukan beton adalah sebagai bahan pengisi dalam campuran beton. Pasir putih dari daratan bintan ini merupakan pasir yang diambil di daerah daratan di bintan dan pasir bekas galian bauksit ini merupakan pasir hasil bekas pertambangan bauksit di wilayah kepri. Akan tetapi sayangnya pasir ini tidak di manfaatkan oleh masyarakat setempat dalam pembuatan bangunan gedung. Penelitian ini bertujuan untuk mencari perbandingan antara pasir putih dari daratan bintan dan pasir bekas galian bauksit manakah yang lebih baik untuk digunakan. Penelitian ini menggunakan beton dengan mutu k-250, yang diuji pada umur 3,7,14,21 dan 28 hari. Penelitian ini menggunakan metode eksperimental yang diuji langsung pada Laboratorium PUPRP serta PT. Seraya Beton Perkasa. Dari perbandingan hasil pengujian kuat tekan beton pada umur 3,7,14,21 dan 28 hari, pasir putih daratan bintan menghasilkan kuat tekan dengan nilai yang tinggi yaitu 345.66 kg/cm² sedangkan pasir bekas galian bauksit menghasilkan nilai kauat tekan 317.24 kg/cm². Yang dimana dapat diketahui bahwa pasir putih daratan bintan lebih baik dibandingkan pasir bekas galian bauksit. dan juga, kedua pasir ini dapat digunakan untuk bangunan gedung karena sudah memenuhi persyaratan.
IDENTIFIKASI RESIKO KECELAKAAN PERLINTASAN SEBIDANG DI JALAN SOROWAJAN BARU, KOTA YOGYAKARTA Suryanto Suryanto; Indra Suharyanto; Aulia Ull Umam
CivETech Vol 5 No 1 (2023): CivETech
Publisher : Fakultas Teknik Universitas Cokroaminoto Yogyakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47200/civetech.v5i1.1552

Abstract

Untuk mengetahui kinerja perlintasan sebidang diperlukan identifikasi resiko kecelakaan perlintasan sebidang yang menyangkut evaluasi perlintasan sebidang, prediksi dan probabilitas kecelakaan. Evaluasi Perlintasan Sebidang dinyatakan dengan perbandingan kondisi perlintasan Perlintasan sebidang JPL 348, Jalan Sorowajan Baru, Kota Yogyakarta yang ada dengan standar teknis menurut Peraturan Direktur Jenderal Perhubungan Darat Nomor : SK.770/KA.401/DRJD/2005, terdiri data teknis, rambu, marka dan isyarat. Tidak semua kinerja Perlintasan sebidang JPL 348 memenuhi standar teknis menurut Peraturan, Resiko kecelakaan dihitung berdasarkan Departemen Perhubungan AS, Federal Administrasi Jalan Raya meliputi prediksi tumbukan awal, tumbukan per tahun di perlintasan a= 4935, Probabilitas Kecelakaan Fatal= P(FA | A) =0,1492, Probabilitas kecelakaan cedera= P(IA/A)= 0,2658