Jurnal Radiografer Indonesia
ISSN : 26209950     EISSN : 28077415     DOI : https://doi.org/10.55451/jri.v1i1
Core Subject : Health,
Jurnal Radiografer Indonesia (JRI) merupakan jurnal PARI yang berisi tulisan ilmiah di bidang radiologi, antara lain Radiografi Konvensional, Radiografi Digital, CT Scan, MRI, Kedokteran Nuklir, Radioterapi dan Ilmu-ilmu terkait lainnya dalam Radiologi.
Articles 110 Documents
PERBANDINGAN INFORMASI CITRA ANTARA SEQUENCES T2 FAST FIELD ECHO DAN SUSCEPTIBILITY WEIGHTED IMAGING PADA PEMERIKSAAN MRI BRAIN IRISAN AXIAL DENGAN KASUS MICROBLEEDS Afandi; Luthfi Rusyadi; Fatimah; Jeffry Ardiyanto
JRI (Jurnal Radiografer Indonesia) Vol. 1 No. 1 (2018)
Publisher : Perhimpunan Radiografer Indonesia (PARI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (429.391 KB) | DOI: 10.55451/jri.v1i1.3

Abstract

Background : The Gradient echo sequence is a sequence using RF excitation pulse varied and with flip NMV through various angle (Instead of 900). It’s sensitive in detecting the present of hemorrhages that have susceptibility and blooming effect to hemorrhages. T2 fast field echo (T2 FFE) and susceptibility weighted imaging (SWI) are part of the gradient echo pulse sequences, in which T2 FFE sequences is conventional non- steady state imaging 2D milti-slice and SWI is 3D velocity compensated sequence gradient echo. On both the sequence is very good for asses the hemorrhages particularly microbleeds. This study aims to determine differences in image information and determine the most optimal image information between T2 FFE and SWI sequences in brain MRI axial slices with microbleeds cases. Methods : Type of research is quantitative experimental approach. The data was taken from October to November 2016 at Radiology Installation of Siloam Hospital Lippo Village. The study populations was all examinations brain MRI with the microbleeds cases, 5 samples with inclusion criteria described. Scanning by using T2 FFE and SWI sequences, then evaluation by respondents furthermore the data was processed using kappa test, and analyzing the date using wilcoxon test, and then to get an assesment of the most optimal images seen from the mean rank wilcoxon test. Results : The result was p-value 0,025 (p<0,05) means that Ho refused and Ha accepted, so that statistically showed significant differences at images information between T2 FFE and SWI sequences in examinations brain MRI axial slices with microbleeds case, with mean rank on SWI sequence is 3, and mean rank on T2 FFE is 0, so it’s can be concluded that SWI sequence produces a better images information on the examination brain MRI axial slices with microbleeds cases than T2 FFE sequence. Conclusion : there is a difference of images information between T2 FFE and SWI sequences in Brain MRI axial slices with microbleeds cases, and SWI sequences produces a better images information on the Brain MRI axial slices with microbleeds cases.
PERBEDAAN INFORMASI CITRA SEKUEN THICK-SLAB SINGLE-SHOT FAST SPIN ECHO (SS-FSE) DAN SEKUEN 3D-FAST SPIN ECHO (FSE) PADA PEMERIKSAAN MAGNETIC RESONANCE CHOLANGIOPANCREATICOGRAPHY (MRCP) Anisa Nur Istiqomah; Hermina Sukmaningtyas; Luthfi Rusyadi
JRI (Jurnal Radiografer Indonesia) Vol. 1 No. 1 (2018)
Publisher : Perhimpunan Radiografer Indonesia (PARI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (394.296 KB) | DOI: 10.55451/jri.v1i1.4

Abstract

Backgroud:There are sequences that have the same image and assessment functions are sequences thick-slab SS- FSE and 3D-FSE. Each hospital uses a different sequences for MRCP examination. Based on the different uses of these sequences carried out research with the aim to determine differences in image information thick-slab SS- FSE and 3D-FSE sequences and also to see better sequence for MRCP examination. Methods: Type of this research is quantitative with observation approach. Ten patient have diagnose system biliaris and pancreas disease undergo MRCP with thick-slab SS-FSE and 3D-FSE sequence. Assessment images information using questionnaire that were read by three radiologist. Inter observer agreement examined by Cohen’s Kappa test. Analysis to discover the different of anatomy information, conspicuity of lesion, and artifact using cross tabulation and Wilcoxon test. To discover better sequence observe the mean rank of wilcoxon test. Results: Result of this research demonstrate that there’s significantly different between sequence thick-slab SSFSE and 3D-FSE toward anatomy information p=0,010; conspicuity of lesion p=0,013; artifact p=0,008; Cystic Duct p=0,157; intra hepatic duct p=0,405. Conclusion:There are significant image informationdifferences of Thick-slab SS-FSE and 3D-FSE sequences in MRCP examination.Better sequence for MRCP examination is thick-slab SS-FSE because short acquisition time and less artifact also showing conspicuity of lesion clearly. Sequence 3D-FSE still used to see small ductus as intra hepatic duct.
PENGARUH VARIASI ROTATION TIME TERHADAP NILAI DLP (DOSE LENGTH PRODUCT) DAN IMAGE NOISE PADA PESAWAT MSCT 128 SLICE (STUDI KASUS) Asmaul Fauziyah; Amillia Kartika Sari; Soegardo Indra P; Anggraini Dwi Sensusiati; Pramono
JRI (Jurnal Radiografer Indonesia) Vol. 1 No. 1 (2018)
Publisher : Perhimpunan Radiografer Indonesia (PARI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (686.232 KB) | DOI: 10.55451/jri.v1i1.5

Abstract

Background: The patient's dose and image noise illustrate the quality of the CT scan. DLP (Dose Lenght Product) is a dose description on a CT-Scan tool by providing a measure of the total amount of radiation exposure for a series of scans. While image noise is the difference / variation in pixel values contained in an image matrix. The use of rotation time in CT scan is the most likely to contribute to patient dose and image noise. Method: Toshiba Aquilion 128 MSCT aircraft and Acrilyc phantom were used as material in this study. The parameters on the CT-Scan tool used are the suitability test parameters, namely at kV 120, 400mA, slice thickness 2 mm, FOV 240. Rotation time variations on CT scan imaging that can be selected are in the range of values ​​of 0.35s, 0.375s, 0.4s , 0.45s, 0.5s, 0.6s, 0.75s, 1.0s while the other parameters are the same. From each rotation time value, the estimated dose value is the DLP value on the CT Scan monitor screen (Summary). Furthermore, the scanning results measure the noise value by measuring the ROI on the middle side of the area around a diameter of 2-3 cm2. The measurement results are recorded and entered into tables, graphs and tests with statistics, and test the effect (regression) as hypothesis testing with a significant value (α) <0.05. This research was conducted in the Radiology IRD unit of Dr. RSU. Soetomo. Results: Obtained DLP values ​​of 37.3 mGy.cm, 28.4 mGy.cm, 23.1 mGy.cm, 19.5 mGy.cm, 17.8 mGy.cm, 16 mGy.cm, 15.1 mGy.cm and 14.2 mGy.cm at rotation times of 1.0s, 0.75s, 0.6s, 0.5s, 0.45s, 0.4s, 0.375s, 0.35s. For the assessment of image noise the results are 5.6 HU, 5.5 HU, 5.3 HU, 5.1 HU, 4.8 HU, 4.5 HU, 4.1 HU and 3.4 HU at rotation time 0 , 35s, 0.375s, 0.4s, 0.45s, 0.5s, 0.6s, 0.75s, 0.5s, and 1s. From the above results obtained the value of DLP at the lowest radiation dose on the use of rotation time of 0.35 sec which is 14.2 mGy.cm and the largest at 1.0 sec is 37.3 mGy.cm, with a regression coefficient of 1,785 + 35,507 with a value of 0,000 so that the effect is very significant . In this case it shows that the contribution of rotation time effect on optimization of the estimated DLP value is 100%. Noise value at the variation of rotation time values ​​found that 0.35 s produces an optimum noise of 5.6 HU and 1.0 sec produces the smallest noise of 3.4 HU. This can be seen from the regression coefficient of 6,637 - 3,344 with a value (α) <0.05. In this case it shows that the contribution of rotation time to the image noise value is 97.8% while the remaining 2.2% is influenced by other variables contained in the model. Conclusion: The use of slower rotation time is still recommended to produce optimal image quality in certain cases, because the noise value is close to zero and is still within the limits of the normal noise value. Each increase in rotation time of one unit will increase the optimization value of the estimated DLP by 35.507, so that it can be said there is no significant difference even though the measurement looks very varied in value.
ANALISIS TINGKAT PAPARAN RADIASI DI AREA SETINGGI MATA DOKTER OPERATOR SELAMA PEMERIKSAAN DIAGNOSTIK CORONARY ANGIOGRAPHY DI RUANG CATHLAB Devi Aprilia Primaningtyas; Soegardo Indra Praptono; Lailatul Muqmiroh
JRI (Jurnal Radiografer Indonesia) Vol. 1 No. 1 (2018)
Publisher : Perhimpunan Radiografer Indonesia (PARI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (430.406 KB) | DOI: 10.55451/jri.v1i1.6

Abstract

Background : The radiation exposure of interventional cardiology can provide biological effects on patients and workers that is deterministic and stochastic effects. One organ that accepts the possibility of deterministic effects are the eyes. To find out the possibility of cataracts is measuring the level of radiation exposure in the area of radiation workers at eye level during the diagnostic coronary angiography procedures. Method: the measurement of the level of radiation exposure in the area of physician eye-level using a survey meter directly at the physician position. Measurements were made on the variation of the projection during diagnostic coronary angiography examination including PA-Cranial, LAO-Cranial, LAO-Caudal, RAO-Cranial, RAO-Caudal, RAO and LAO. Result: Measuring the level of radiation exposure in the area at physician eye-level during diagnostic coronary angiography obtained on sample A of 15.34 μSv for 69.17 seconds (1 minute 9.17 seconds and sample B of 25.11 μSv for 46 seconds. The total dose, DAP (dose Area Product) and fluoroscopy time of the operator A is higher than the operator B. Conclusion: The level of radiation exposure in the area of physician eye-level during diagnostic coronary angiography examination obtained does not exceed the dose limit value (NBD) is 75 μSv /h.
PENGARUH VARIASI BERAT BADAN TERHADAP KENAIKAN TEMPERATUR TUBUH DAN NILAI SPECIFIC ABSORPTION RATE PADA PEMERIKSAAN MRI BRAIN Dimas Prakoso; Fatimah; Bagus Abimanyu; Dartini
JRI (Jurnal Radiografer Indonesia) Vol. 1 No. 1 (2018)
Publisher : Perhimpunan Radiografer Indonesia (PARI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (412.683 KB) | DOI: 10.55451/jri.v1i1.7

Abstract

Background : MRI brain is a routine examination, after finished examination will felt warm and sweaty on the back. The heat produced by the SAR effect affected by the body weight examined. This research to determine increasing body temperature and SAR value after MRI brain examination based on different body weight. Methods :The kind of this research is experiment. Research has been done at thirteen (13) samples with characteristic as follows : consisted of 3 men and 10 women with variation of body weight 45 kg until 75 kg. Samples had normal body temperature, no abnormalities in the head, and no claustrophobia. Each samples measure body weight and body temperature before MRI examination, then performed examination of MRI brain used brain routine protocol during 19 minutes 49 seconds. After that, measure body temperature again to find the increasing body temperature and saw the SAR value on SAR information. Then analyzed the affection of the variation of body weight and increasing body temperature, and variation of body weight and SAR value. Data were analysed statistically by using Linear Regression test. Results : The results showed that there were significant affection between variation of body weight and increasing body temperature (p value<0,05) significant with very strong influence (R Square=0,889) and negative correlation with equation y=2,098–0,024x.On variation of body weight and SAR value showed that there were significant affection (p value<0,05) with medium influence (R Square=0,596) and positive correlation with equation y=0,214+0,004x. Conclusion : Based on these results indicate thatmore body weight, increase body temperature will decrease due to the fat in people overweight and more body weight, SAR value will increase according the amount of RF exposure required
PERBEDAAN PEMBOBOTAN T2 TURBO SPIN ECHO (TSE) MRI BRAIN POTONGAN AXIAL ANTARA PENGGUNAAN SENSITIVITY ENCODING (SENSE) DENGAN TANPA SENSE : EVALUASI PADA SIGNAL TO NOISE RATIO (SNR) DAN SCAN TIME Fani Susanto; Gunawan Santoso; Bagus Abimanyu
JRI (Jurnal Radiografer Indonesia) Vol. 1 No. 1 (2018)
Publisher : Perhimpunan Radiografer Indonesia (PARI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1118.911 KB) | DOI: 10.55451/jri.v1i1.8

Abstract

Backgroud: MRI examination of brain often find patients who are less cooperative, thus requiring rapid acquisition techniques. Parallel imaging technique sensitivity encoding (SENSE) utilizing the spatial information RF coil phased array to reduce the acquisition time by reducing the number of sampling lines K space therefore produce quality and good spatial resolution, but its has the limitations, namely the reduction of signal to noise ratio (SNR). SENSE is used along with pulse sequence one of turbo spin echo (TSE). The purpose of this research was to determine the differences in SNR and scan time on T2 weighted TSE MRI of brain axial slices between use SENSE with no SENSE. Methods: This research is a quantitative study with an experimental approach. Data were collected from May to June 2016 in Radiology Unit Premier Bintaro Hospital by calculating the SNR value through software for the region of interest (ROI) and calculate the scan time through the scan timer on the workstation monitor. Data was analyzed by statistical tests with SPSS 16 software using paired T-test and descriptive. Results: From the statistical test result known that the SNR on T2 TSE between use SENSE with no SENSE the p-value 0,000 (p <0,05). This is because the encoding between the two images are different, the image of the T2 TSE without SENSE contained use of pulses in 1800 approached TE effectively so shallow gradients produce echo maximum, while the image of the T2 TSE using SENSE there is a reduction in line phase encoding in the K space and their g-factor causing reduced SNR. From the analysis descriptively known that the scan time on T2 TSE between use SENSE with no SENSE by reducing scan time for 1 minute 24 seconds (49,01%). This is because the acquisition techniques are different between the two images, the image without SENSE T2 TSE contained ETL in the filling K space, while the T2 TSE images using SENSE R-factors are causing sampling did not fill all the K space so that the scanning time is reduced. Conclusion: There is a difference in SNR and scan time of T2 weighted TSE MRI of brain axial slices between use SENSE with no SENSE
ANALISA PERBEDAAN INFORMASI ANATOMI THORAKS PADA PROYEKSI ANTERO POSTERIOR (AP) SUPINE ANTARA PENYUDUTAN ARAH SUMBU SINAR 50 CAUDAD DAN VERTIKAL TEGAK LURUS Nugroho Yudho Susilo; Bagus Abimanyu
JRI (Jurnal Radiografer Indonesia) Vol. 1 No. 1 (2018)
Publisher : Perhimpunan Radiografer Indonesia (PARI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (329.153 KB) | DOI: 10.55451/jri.v1i1.9

Abstract

Backgroud: A finding about different central ray arrangement in the AP supine projection which are using 5° caudad and vertically central ray that occur in the clinical practice hospital turns into the reason of developing this research. A research has been carried out in the clinical practice hospital about thorax x - ray examination with AP supine projection that used 5° caudad and vertically central ray in order to reveal the anatomical information differences between thorax x-ray examination with AP supine projection with the variation of central ray angulation and also to determine the most effective degree of central ray which can demonstrate anatomical information accurately. Methods: The method of this research is quantitative with survey approachment, and qualitative approachment in addition. Data collected by copying 60 thorax x-ray radiograph, admission filling of questioner and interview. The questioner filled by 3 respondents who are radiologist. Those data from the respondents are processed and analysed by using statistical analysis. Results: Interviewing data analysed by data reduction, data presentation, drawing of conclusion and verification. Based on the result of the SPSS statistical Mann-Whitney analysis test, it has been revealed that there are differences of anatomical information between thorax x -ray examination with AP supine projection which are using 5° caudad and vertically central ray, demonstrated by magnification of clavicle, foreshortening of clavicle, foreshortening of costae’s distance, superposition of 1st-5th costae by clavicle, and superposition between anterior and superior co stae. It has been determined that vertically central ray radiograph can demonstrate anatomical information of thorax x - ray examination with AP supine projection accurately by the highest value of Mann -Whitney mean rank 44,68.
PERBANDINGAN KESETARAAN NILAI DOSIS SERAP BOLUS LILIN DAN CONFORMAL BOLUS TERHADAP JARINGAN LUNAK PADA PERENCANAAN TEKNIK RADIOTERAPI Yudha Aries Pratama; Muhammad Fadli
JRI (Jurnal Radiografer Indonesia) Vol. 1 No. 1 (2018)
Publisher : Perhimpunan Radiografer Indonesia (PARI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (438.384 KB) | DOI: 10.55451/jri.v1i1.10

Abstract

Backgroud: The purpose of this paper is to measure equality volue of wax bolus and conformal bolus againts soft tissue. This research is qualitative descriptive. This study is observed at Radiotherapy Department MRCCC Siloam Hospitals Semanggi. The methode of this research is measure, comparing a result and the research instrument used is electrometer and paper work to notice a result of measuement. Methods: The device used is linear accelerator with type Clinac iX, ionization chamber adn electrometer. please note the room temperature and room preasure before measuring. Stack 10 plate of slab phantom with 1cm thickness and 30x30cm2 wide on the linac table. After that put ionization chamber into the 10th slab phantom, add more 9 plate of slab phantom with same thickness and 1 plate of slab phantom with 0.5cm thickness. Arrange the stack of slab phantom until the position in the middle of lasser in that room. Connect the ionization chamber with electrometer who locate in oprator room. In order to we can see the result at oprator room. Stacks a slab phantom , paraffin wax bolus and conformal bolus each having a thickness 0.5cm alternately. Measuring 5 times in every material with 6MV and 15MV energy. Result: The result is in 10-8C. That result must be converted into absorb dose (cGy). Compare the result of wax bolus and conformal bolus against the result of slab phantom.
PERBEDAAN INFORMASI ANATOMI PADA SEKUEN T1WI TSE POST GADOLINIUM DENGAN FATSATURASI MAUPUN TANPA FAT SATURASI PADA PEMERIKSAAN MRI LUMBAL Marichatul Jannah; Sugiyanto; Irwan Katili; Edy Susanto
JRI (Jurnal Radiografer Indonesia) Vol. 1 No. 1 (2018)
Publisher : Perhimpunan Radiografer Indonesia (PARI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (485.126 KB) | DOI: 10.55451/jri.v1i1.11

Abstract

Backgroud: Fat Saturation is useful in MR Imaging to supress high signal from fatty tissues. When Fat Saturation is used in combination with gadolinium, enhancing lessions become more conspicuous. T1 post-contrast examination usually does not require fat saturation, in Dr. Hasan Sadikin Hospital Bandung combined with fat saturation. Another interesting things are the tumor, metastasis and inflammation will be isointense on T1 enhance contrast but still added Fat Saturation. The objectives of this research is to find out anatomy information differences between TIWI TSE Post Gadolinium with and without Fat Saturation and acknowledge which better anatomy information between two pulse sequences. Methods: The research uses quantitative method with experimental approach and questionnaire. The research takes place at Radiology Unit RSUP Dr. Hasan Sadikin Bandung on May-June 2013 with 20 patients with a variety of cases using gadolinium and 5 respondents. Data analysis uses univariate method, wilcoxon test, and friedman test Results: The research result shows that are differences anatomy information between TIWI TSE Post Gadolinium with and without Fat Saturation by P value 0,000 (sig.<0,05). The anatomy information has good present on the first treatment T1WI TSE Post Gadolinium with Fat Saturation pulse by mean rank 2,99
PERBEDAAN INFORMASI CITRA DIAGNOSTIK ANTARA SEKUEN T2 TSE STIR DAN T2 TSE DIXON PADA PEMERIKSAAN MRI LUMBAL POTONGAN SAGITAL DENGAN KASUS RADICULOPATHY Fisnandya Meita Astari; Rasyid; Fatimah
JRI (Jurnal Radiografer Indonesia) Vol. 1 No. 1 (2018)
Publisher : Perhimpunan Radiografer Indonesia (PARI)

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (733.958 KB) | DOI: 10.55451/jri.v1i1.12

Abstract

Backgroud: T2 Weighted Image Turbo Spin Echo Short Tau Inversion Recovery (T2 TSE STIR) is a sequence to get the image pathologic which can reveal of tissue along surrounding pathology with fat suppresion technique. T2 Weighted Image Turbo Spin Echo Dixon is a sequence to get the image pathologic whic can reveal of tissue along surrounding pathology with fat and water suppresion technique. Based on observations at Dr. Hasan Sadikin Bandung Hospital, in the examination of MRI Lumbal using T2 TSE sequence with Dixon fat suppresion technique, while according to The American College of Radiology (2012), using STIR fat suppresion technique. The purpose of this research was to know the difference of information diagnostic image that is produced between T2 TSE STIR and T2 TSE Dixon sequences on the examination of MRI lumbal sagittal slice with Radiculopathy case. Methods: This research of type is experiment. The study was conducted with a 1,5 Tesla MRI at Installation Radiology of General Hospital Dr. Hasan Sadikin Bandung. The research took from of the 22 images of MRI lumbal sagittal slice from T2 TSE STIR and T2 TSE Dixon sequences with Radiculopathy cases. Assesment of the image was done by two respondents and Kappa test was conducted. Furthermore, the results of respondents assessment was analyzed by Wilcoxon different test. Results: The results showed that the research result Ho rejected and Ha accepted which mean there is a differences of information diagnostic image between T2 TSE STIR and T2 TSE Dixon sequences on the examination of MRI lumbal sagittal slices with Radiculopathy case with p value = 0,001 (p <0,05). Conclusion: T2 Sequence TSE Dixon can produce MRI images with more specific and homogeneous fat suppresion, thus providing more informative diagnostic information than T2 TSE STIR sequences.

Page 1 of 11 | Total Record : 110