cover
Contact Name
Remigildus Cornelis
Contact Email
remi@staf.undana.ac.id
Phone
+6281295357255
Journal Mail Official
forteks@undana.ac.id
Editorial Address
Jl. Adisucipto, Penfui-Kupang, Lasiana, Klp. Lima, Kota Kupang, Nusa Tenggara Timur., Indonesia
Location
Kota kupang,
Nusa tenggara timur
INDONESIA
Jurnal Forum Teknik Sipil
ISSN : 27766012     EISSN : 27768155     DOI : 10.35508
Jurnal Forum Teknik Sipil (ForTekS) adalah jurnal Teknik Sipil yang bertujuan untuk menyebarluaskan hasil riset-riset ataupun kajian pustaka pada bidang Teknik Sipil. Artikel-artikel pada jurnal ini difokuskan kepada bidang teknik sipil atau aplikasinya. Beberapa bidang teknik sipil spesifik yang diterima adalah : Struktur dan kegempaan Hidro Transportasi Geoteknik Manajemen Konstruksi Lingkungan dan lahan kering
Articles 37 Documents
Analisis Kinerja Struktur Rangka Beton Bertulang Beraturan Dengan Penambahan Tingkat Menggunakan Struktur Baja Hilario Alberto Kono; Partogi H Simatupang; Ruslan Ramang
JURNAL FORUM TEKNIK SIPIL (J-ForTekS) Vol 1 No 2 (2021): Volume 1 Nomor 2 September 2021
Publisher : Universitas Nusa Cendana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (839.203 KB) | DOI: 10.35508/forteks.v1i2.4847

Abstract

The change of plans on gradually development in building structure can be occur with building operational consideration and owner financial. The purpose of this study was to determine the level of performance of the reinforced concrete frame structure with additional levels using steel structures with different span variations. The results of the analysis are used to determine how big the deviation is between levels and to control the level of structure performance. The conclusion of the study shows that the performance level of the structural model analyzed is immediate occupancy (IO) with a total drift ratio and interstorey drift ratio value of the initial building structure (C3S0) in the x direction and y direction of 0.0004, and for variations in building structure with the addition of levels using steel structures (C3S1, C3S2, C5S1, C5S2, C7S1, C7S2) in the x direction ranging from 0.0005-0.0007 and in the y direction ranging from 0.0010-0.0024.
Studi Pengaruh Tangga pada Pemodelan Struktur Bangunan Beraturan Akibat Beban Gempa dengan Menggunakan Software Etabs Jendrianus Hendro Takesan; Partogi H Simatupang; Wilhelmus Bunganaen
JURNAL FORUM TEKNIK SIPIL (J-ForTekS) Vol 1 No 2 (2021): Volume 1 Nomor 2 September 2021
Publisher : Universitas Nusa Cendana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (610.46 KB) | DOI: 10.35508/forteks.v1i2.4886

Abstract

Dalam mendesain dan menganalisis struktur gedung menggunakan software, seringkali tangga itu ditiadakan, sehingga kurang diketahui bagaimana perbedaan dan dampak dari masing-masing respon struktur. Oleh karena itu, penelitian ini bertujuan untuk mendapatkan dampak dan perbedaan dari struktur gedung yang didesain menggunakan software. Metode yang digunakanan adalah analisis respon spektrum berdasarkan SNI 2019. Struktur gedung didesain menjadi 3 jenis, yaitu struktur gedung tanpa tangga, struktur gedung tanpa tangga dengan void, dan struktur gedung dengan tangga. Dalam penelitian ini analisis strukturnya menggunakan Software Etabs 2016. Berdasarkan hasil penelitian dapat diketahui bahwa terdapat perbedaan dari 3 jenis struktur yang telah dianalisis, yaitu pada gaya geser dasarnya. Model 3 memiliki nilai yang lebih besar dari model 1 dan model 2 (Model 3: 2521,7 kN > Model 1: 1713,5 kN > Model 2: 1661,04 kN). Kemudian untuk gaya dalamnya juga menunjukan perbedaan yang cukup besar, hal ini akan berpengaruh pada jumlah tulangan-tulangannya. Dan yang terakhir untuk nilai perpindahan, pada gedung tanpa tangga menunjukan nilai perpindahan yang lebih besar daripada gedung dengan tangga, hal ini disebabkan oleh tangga yang mengakibatkan nilai kekakuan menjadi lebih besar dari nilai perpindahannya. Perbedaan juga ada pada gedung pertama yang memiliki nilai perpindahan yang lebih besar dari gedung kedua, hal ini disebabkan karena terdapat bukaan void pada gedung kedua.
Studi Parametrik Balok Tinggi Beton Bertulang dengan Bukaan (Web Openings) Menggunakan Metode Strut and Tie Fransiskus Lidyo Kapitan; Remigildus Cornelis; Sudiyo Utomo
JURNAL FORUM TEKNIK SIPIL (J-ForTekS) Vol 2 No 2 (2022): Volume 2 No.2 September 2022
Publisher : Universitas Nusa Cendana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1194.21 KB) | DOI: 10.35508/forteks.v2i2.4924

Abstract

Tujuan penelitian ini adalah untuk mengetahui pengaruh bukaan (web opening) terhadap perilaku struktur, konfigurasi penulangan, dan perilaku mekanik pada balok tinggi menggunakan Metode Strut-and-Tie. Model balok tinggi yang digunakan berperletakan sederhana dengan panjang 6 m dan tinggi 2 m. Variasi pemodelan diterapkan pada posisi bukaan yaitu pada daerah geser dan daerah lentur. Hasil dari penelitiaan menunjukan bukaan pada daerah geser menyebabkan peningkatan perilaku struktur yang cukup besar sehingga diperlukan tulangan tambahan pada setiap sisi bukaan. Pada balok tinggi beton bertulang yang didesain untuk menahan beban yang sama, bukaan pada daerah geser menyebabkan struktur balok tinggi beton bertulang semakin getas sedangkan bukaan pada daerah lentur menyebabkan struktur balok tinggi beton bertulang semakin daktail.
Evaluasi Pembiayaan Pembangunan Infrastruktur Pedesaan Danang Gunarto; Trimawan .
JURNAL FORUM TEKNIK SIPIL (J-ForTekS) Vol 2 No 1 (2022): Volume 2 Nomor 1 Mei 2022
Publisher : Universitas Nusa Cendana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (412.472 KB) | DOI: 10.35508/forteks.v2i1.5462

Abstract

Volume estimation and the financial project are essential as technical calculations. This research is to study urban project finances held without proper planning, and the research sample is nine urban. The research method compares the budget available and the estimation calculation based on field observation according to field observation. Unit price analysis use SNI (Standart Nasional Indonesia) method. From the analysis results, the calculated cost and budget ceiling are different. According to field observation, the average budget ceiling is Rp 116,000,000.00, higher than the computed cost of Rp 105,900,000.00. However, according to field observation, the standard deviation of estimation calculation is Rp 46,400,000.00, and the budget is Rp 15,700,000.00. This matter shows that the quality of urban infrastructure projects is varied.
Analisis Indeks Kekeringan Menggunakan Standardized Precipitation Index (SPI) Method pada Daerah Kabupaten Timor Tengah Selatan Willybrordus Kurniawan Hima; I Made Udiana; Judi K. Nasjono
JURNAL FORUM TEKNIK SIPIL (J-ForTekS) Vol 2 No 1 (2022): Volume 2 Nomor 1 Mei 2022
Publisher : Universitas Nusa Cendana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1015.566 KB) | DOI: 10.35508/forteks.v2i1.5464

Abstract

Due to the low rainfall, it is relatively uneven in each sub-district in Timor Tengah Selatan (TTS) Regency. It causes some rivers to be drought-prone in the dry season. This study aims to determine the largest drought index and map the drought distribution in the South Central Timor (TTS) Regency. The drought index analysis uses the Standardized Precipitation Index (SPI) Method. The data used is monthly rainfall data for ten years (2009-2018) of ten rain stations. Then, mapping of drought distribution rainfall using ArcGIS Software. The results of the drought index analysis showed that in the 1-month deficit period, the largest drought index was -3.61, which occurred in March 2014 at the Oeekam Rain Station. In the 3-month deficit period, the largest drought index was -3.19, which occurred in March 2010 at the Nulle Rain Station and in November 2015 at the Kesetnana Rain Station. The findings of the drought distribution map study suggest that during the 1-month shortfall period, all sub-districts experienced drought in January, February, and April. Meanwhile, in the 3-month deficit period, drought occurs evenly for all sub-districts only in June.
Analisis Perbandingan Kinerja Seismik dari Struktur Gedung dengan Pelat Konvensional, Waffle Slab, dan Flat Slab Yohanes Alexander Rupidara; Remigildus Cornelis; Tri M.W. Sir
JURNAL FORUM TEKNIK SIPIL (J-ForTekS) Vol 2 No 1 (2022): Volume 2 Nomor 1 Mei 2022
Publisher : Universitas Nusa Cendana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (983.601 KB) | DOI: 10.35508/forteks.v2i1.5496

Abstract

Indonesia is a country with high earthquake risk because it is located in the path of the most active earthquake in the world. It makes Indonesia situated in a region with a high earthquake intensity. The study aimed to determine the seismic performance levels of building structures with conventional slabs, waffle slabs, and flat slabs with the time history analysis method. There are three models of structures studied, namely building structures with conventional plates, building structures with waffle slabs, and building structures with flat slabs, with a 5-story structure system, where the longest and shortest span has the same size of 20 m and the height of each level 4 m. This study showed the largest displacement was 235.82 mm in building structures with waffle slabs and the smallest displacement was 146.49 mm in building structures with flat slabs. The largest drift is 0.012 on a building structure with a waffle slab, and the smallest drift is 0.007 on a building structure with a flat slab. The level of seismic performance produced from all three types of structures varies from immediate occupancy (IO) to damage control (DC).
Analisis Faktor Pemilihan dan Tingkat Kepuasan Pengguna Jasa Angkutan Umum Kota Kupang pada Pandemi COVID19 John H Frans; Ananda Cicelya Afny Saranga; Jusuf J.S. Pah
JURNAL FORUM TEKNIK SIPIL (J-ForTekS) Vol 2 No 2 (2022): Volume 2 No.2 September 2022
Publisher : Universitas Nusa Cendana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (322.597 KB) | DOI: 10.35508/forteks.v2i2.6317

Abstract

Angkutan umum tidak terlepas dari berbagai masalah. Penelitian ini bertujuan untuk mengetahui faktor – faktor yang mempengaruhi pemilihan angkutan umum dan tingkat kepuasan terhadap kinerja angkutan umum di Kota Kupang. Analisis yang digunakan dalam penelitian ini adalah analisis mean, analisis faktor dan analisis Quality Function Deployment (QFD). Analisis faktor – faktor yang mempengaruhi pemilihan angkutan umum di Kota Kupang berdasarkan hasil analisis mean didapat nilai mean tertinggi adalah 4,45 untuk faktor X17sedangkan nilai mean terendah adalah 3,34 untuk faktor X8. Hasil analisis faktor didapat presentase tertinggi untuk faktor kesehatan dengan nilai varimax rotation 38,932% sedangkan presentase terendah untuk faktor biaya dengan nilai varimax rotation 6,210%. Analisis untuk tingkat kepuasan dengan analisis Quality Function Deployment (QFD) didapat nilai untuk tingkat kepuasan lebih kecil daripada nilai target sehingga perlu dilakukan perbaikan terhadap kinerja pelayanan. Dimana langkah – langkah perbaikan yang menjadi prioritas paling pertama adalah penerapan protokol kesehatan Covid 19 dengan nilai absolut parameter teknik 106,907 sedangkan yang menjadi prioritas terakhir adalah tingkat keamanan dan kenyamanan penumpang dalam angkutan dengan nilai absolut 521,251.
Pengaruh Variasi Girder Terhadap Perilaku Struktur Atas Jembatan Beton Prategang Akibat Gempa Horizontal Septiano H.E. Tefa; Dantje A.T Sina; Andi Kumalawati
JURNAL FORUM TEKNIK SIPIL (J-ForTekS) Vol 2 No 1 (2022): Volume 2 Nomor 1 Mei 2022
Publisher : Universitas Nusa Cendana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (532.144 KB) | DOI: 10.35508/forteks.v2i1.6624

Abstract

Earthquakes are dangerous natural disasters and cause damage on a large scale. Therefore, this study aimed to determine the mass participation of the structure, structure capacity, and performance levels. The analysis was carried out based on the spectral response, pushover, and FEMA-356 methods. In anticipation of the damage, the design of earthquake-resistant structures has become essential in structural design, especially in the bridge structure design. The bridge samples in this study were type I prestressed concrete bridges with a length of 37 m and a width of 4 m using ten variations of girders located at the Temef Dam. The results obtained are the most critical structural conditions occur in the transverse direction. The base shear maximum capacity is more significant in the longitudinal direction than in the transversal direction. The maximum displacement capacity is higher in the transversal direction than in the longitudinal direction. The effect of cross-sectional area and cross-sectional inertia of the beam girder on the structural’s capacity is the greater the cross-sectional area and inertia of the beam girder, the greater the capacity of the structures. All of The structure performance levels were Immediate Occupancy (IO).
Pengaruh Fly Ash pada Stabilisasi Lempung Ekspansive Terhadap Nilai Tegangan Geser dan CBR Elsy E. Hangge; Remigildus Cornelis; Antonius Y. Dom
JURNAL FORUM TEKNIK SIPIL (J-ForTekS) Vol 2 No 1 (2022): Volume 2 Nomor 1 Mei 2022
Publisher : Universitas Nusa Cendana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (312.367 KB) | DOI: 10.35508/forteks.v2i1.6702

Abstract

Expansive clay soils are categorized as poor as subgrades because of their low capacity for bearing soil. Therefore, it needed to stabilize with added lime and fly ash materials. This study aimed to determine the effect of adding lime and fly ash on the bearing capacity of expansive clay in the form of shear stress and CBR values. The research method used is observation, namely testing of physical and mechanical properties in the laboratory. The tests were carried out on the original soil, and soil was stabilized using 5% lime, and the fly ash content was 10%, 20%, 30%, 40%, and 50%. The biggest change in the value of the CBR test occurred in the CBR value that was not submerged after seven days of curing on a variation of a mixture of 5% lime (fixed) and 50% fly ash, which was 11.74% of the original soil CBR value of 1.39%. The largest increase in soil bearing capacity (qu) and undrained soil cohesion (cu) was obtained in the composition of the original soil mixture, 5% lime and 50% fly ash, namely 0.368 kg/cm2 and 0.184 kg/cm2. The results showed that the stabilization of expansive clay using lime and fly ash increased the bearing capacity of the soil.
Studi Perbandingan Penulangan Balok dan Kolom pada Gedung Biro Logistik POLDA NTT Berdasarkan SNI Gempa 2012 dan SNI Gempa 2019 Hernanda A.S. Manalu; Dantje A.T. Sina; Dolly W. Karels
JURNAL FORUM TEKNIK SIPIL (J-ForTekS) Vol 2 No 2 (2022): Volume 2 No.2 September 2022
Publisher : Universitas Nusa Cendana

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (460.521 KB) | DOI: 10.35508/forteks.v2i2.6741

Abstract

Dalam penelitian ini hendak dilakukan perbandingan analisis gempa dinamik berdasarkan SNI Gempa 2012 dan SNI Gempa 2019 menggunakan software ETABS2016, untuk mengetahui pengaruhnya terhadap luas tulangan balok dan luas tulangan kolom. Gedung yang ditinjau adalah gedung Biro Logistik POLDA NTT, gedung dibuat menjadi 4 variasi tingkat yaitu 3 tingkat, 4 tingkat, 5 tingkat dan 6 tingkat, untuk mengetahui pengaruh analisis gempa terhadap luas tulangan akibat variasi kenaikan tingkat. Hasil penelitian ini menunjukkan bahwa luas tulangan untuk semua variasi tingkat dengan SNI Gempa 2019 lebih besar dari SNI Gempa 2012. Perbedaan luas tulangan rata-rata longitudinal balok sebesar 461 mm2, sedangkan perbedaan luas tulangan terbesar longitudinal balok terdapat pada balok B5A sebesar 1614 mm2. Perbedaan luas tulangan rata-rata geser balok sebesar 454 mm2/m, sedangkan perbedaan luas tulangan terbesar geser balok terdapat pada balok B5A sebesar 1460 mm2/m. Perbedaan luas tulangan rata-rata utama kolom sebesar 4448 mm2, sedangkan perbedaan luas tulangan terbesar utama kolom terdapat pada kolom K2 sebesar 6943 mm2. Perbedaan luas tulangan rata-rata geser kolom sebesar 1099 mm2/m, sedangkan perbedaan luas tulangan terbesar geser kolom terdapat pada kolom K4 sebesar 1904 mm2/m. Selanjutnya didapat perbandingan kenaikan luas tulangan rata-rata longitudinal balok antar variasi tingkat adalah 2,25. Perbandingan kenaikan luas tulangan rata-rata geser balok antar variasi tingkat adalah 1,43. Luas tulangan utama kolom antar variasi tingkat pada SNI Gempa 2012 tidak terdapat kenaikan luas tulangan, sehingga tidak dapat dibandingkan. Perbandingan luas tulangan rata-rata geser kolom antar variasi tingkat adalah 1,90.

Page 2 of 4 | Total Record : 37