cover
Contact Name
Prof. Jimmy Pusaka
Contact Email
j_pusaka@kim.lipi.go.id
Phone
-
Journal Mail Official
jurnalinstrumentasi@gmail.com
Editorial Address
-
Location
Kota adm. jakarta selatan,
Dki jakarta
INDONESIA
Instrumentasi
ISSN : 01259202     EISSN : 24601462     DOI : -
Instrumentasi is a scientific journal with high standard of papers that issued biannually by the Research Center for Metrology (Puslit KIM) – LIPI in cooperation with the Association of Instrumentation Society of Indonesia (HiMII). In its first years, Instrumentasi was categorized as a semi-popular magazine in the field of measuring techniques and measuring instruments which has been rapidly improved towards modern technology, and consequently, upgraded to a unique scientific journal in its class. Further, it is also accredited by the Indonesian Institute of Sciences (LIPI). The scientific areas covered by Instrumentasi are those backboned by scientific measurements and thus range from instrument engineering, metrology, testing, and control. All papers submitted are refereed by bona fide reviewers from leading research institutions as well as universities prior to publication to keep their quality meet the standard of the journal. The review is carried out mainly on the basis of originality, novelty, and contribution to scientific measurement. Authors need to complete the ethical clearance form for publication.
Arjuna Subject : -
Articles 61 Documents
THE MAIN PURPOSE FOR THE APPLICATION OF DOUBLE LAYER TIPPING BUCKET SENSORS IN RAINFALL MEASUREMENTS Wijonarko, Sensus
Instrumentasi Vol 41, No 2 (2017)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (732.501 KB) | DOI: 10.14203/instrumentasi.v41i2.114

Abstract

The aim of this study was to investigate the main purpose for the application of double layer tipping bucket sensors based on the existing double layer tipping bucket sensor in Tegal Climatological Station, Indonesian Agency for Meteorology, Climatology, and Geophysics. Hydraulic to electric analogy and rainfall interception models from Calder, Rutter, and Gash were used as the investigation method. The result showed that double layer tipping bucket sensors were dedicated to measure high intensity rainfalls.
PENENTUAN NILAI ACUAN PADA UJI BANDING LABORATORIUM KALIBRASI PADA STUDI KASUS DIAL GAUGE Nugraha, Asep Ridwan; Alfiyati, Nurul
Instrumentasi Vol 41, No 1 (2017)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (4742.321 KB) | DOI: 10.14203/instrumentasi.v41i1.144

Abstract

Penentuan nilai acuan adalah langkah yang paling penting dalam menganalisis hasil uji banding laboratorium kalibrasi. Tingkat kesetaraan standar pengukuran ditentukan oleh kesetaraan nilai ukur dengan nilai acuan yang diperoleh dari pilot sebagai laboratorium acuan atau data perbandingan hasil uji banding laboratorium kalibrasi. Akibatnya, nilai acuan dan ketidakpastian pengukurannya sangat penting untuk dianalisis. Namun, tidak ada metode yang baku untuk menentukan nilai acuan, sehingga ada beberapa metode yang dapat digunakan. Makalah ini melaporkan bagaimana menentukan nilai acuan dalam uji banding laboratorium kalibrasi pada studi kasus dial gauge. Pengukuran dilakukan tiga kali, pertama ketika uji banding dimulai, kedua di tengah uji banding dan ketiga ketika uji banding selesai. Kegiatan ini dilakukan di Laboratorium Metrologi Panjang Puslit Metrologi LIPI dengan menggunakan dial gauge tester sebagai standar dan dial gauge sebagai artefak. Hasil penelitian menunjukkan penyimpangan terdapat drift pengukuran sebesar 0,002 mm. Kata kunci: dial gauge, ketidakpastian pengukuran, nilai acuan, UBLK
EVALUASI KESALAHAN PEMBACAAN PARAMETER UKUR RASIO DARI JEMBATAN KOMPARATOR ARUS SEARAH DI RENTANG 0,1 SAMPAI DENGAN 10 Khairiyati, Lukluk; Wigajatri, Retno; Faisal, Agah
Instrumentasi Vol 41, No 1 (2017)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (585.012 KB) | DOI: 10.14203/instrumentasi.v41i1.143

Abstract

Evaluasi kesalahan pembacaan dari parameter ukur rasio suatu jembatan komparator arus searah (Jembaran DCC) telah dilakukan. Hal tersebut diperlukan untuk menjamin kebenaran dari pelaksanaan kalibrasi resistor standar. Kesalahan pembacaan parameter ukur rasio Jembatan DCC tipe Guildline 6675A diukur menggunakan metode generik dan metode basis interkoneksi resistor yang dikembangkan. Pengukuran ini mencakup parameter ukur rasio pada rentang 0,1:1 sampai dengan 10:1. Berdasarkan kedua metode ini, diperoleh hasil evaluasi kesalahan pembacaan dari parameter ukur rasio dengan menggunakan metode generik diperoleh ketidaklinearan adalah sebesar (0,14 ± 1,68) ppm, sedangkan dengan menggunakan metode basis interkoneksi resistansi diperoleh ketidaklinearan adalah sebesar (0,99 ± 1,78) ppm.Kata Kunci: Jembatan DCC, kesalahan pembacaan, parameter ukur rasio, resistor.
VALIDATION OF SIMPLE UV-VIS SPECTROPHOTOMETRY METHOD BASED ON ICH Q2 (R1) GUIDELINE FOR THE ANALYSIS OF SODIUM HYPOCHLORITE USING RHODAMINE B Munir, Miftakul; Febriana, Siska; Witarti, Witarti
Instrumentasi Vol 41, No 1 (2017)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (311.891 KB) | DOI: 10.14203/instrumentasi.v41i1.80

Abstract

Sodium hypochlorite (NaOCl) has many functions, one of them is as an oxidizing agent in 99Mo/99mTc generator based on ZBM. However, the NaOCl has cytotoxic effect which can harm human body. Hence, there is a need for analytical procedure for its determination. This study describes the validation parameters given by International Conference on Harmonisation (ICH) Q2(R1) to ensure that the UV-Vis spectrophotometric method using rhodamine B is suitable for determination of NaOCl concentration. This method was validated in respect of linearity, specificity and sensitivity. Whereas, the parameter of accuracy and precision is need to be developed to meet the acceptable criteria. The method resulted in a range of linearity, coefficient of correlation and limit of quantification of 0.2 - 4.8 mg L-1, 0.996 and 0.2 mg L-1, respectively.
ANALYSIS ON THE INFLUENCE OF PRESSURE ADJUSTMENT REFERENCE IN PRESSURE GAUGE CALIBRATION BASED ON DKD-R 6-1: 2014 GUIDELINE Ega, Adindra Vickar; Samodro, Rudi Anggoro
Instrumentasi Vol 41, No 1 (2017)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (4632.683 KB) | DOI: 10.14203/instrumentasi.v41i1.82

Abstract

DKD-R 6-1 is a widely used reference document in pressure measuring device (PMD) calibration. However, many of the users do not understand exactly the substance of it. As for example the pressure adjustment during the calibration is based on the reference (STD) reading or the unit under test (UUT) reading, according to the DKD-R 6-1 clause 7 Calibration Method. Therefore, in this research, calibration of barometer as one of PMD, from range 850 hPa to 1050 hPa has been performed to analyze the influence of those two methods to the calibration results and the difficulty or ease in measurement process. The result shows that both methods has different correction of 0,01 hPa, relevant with the uncertainty claim of 0,06 hPa at 850 hPa and 0,05 hPa at 1050 hPa respectively. Measurement by pressure adjustment according to the UUT reading is easier to be performed since UUT has less digit resolution than the reference standard. However, the reading stability of the reference standard needs to be taken into account since it has more digit resolution, in order to get more accurate measurement results. Keywords : barometer, pressure adjustment, DKD-R 6-1, reference standard, UUT
Desain Akselerometer Menggunakan Mikrokontroler Arduino Due Purwowibowo, Purwowibowo; Prasasti, Ninuk Ragil
Instrumentasi Vol 41, No 1 (2017)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (8525.897 KB) | DOI: 10.14203/instrumentasi.v41i1.145

Abstract

Pengembangan sistem pengukuran vibrasi memiliki dampak yang besar dalam sistem pengamatan kondisi dari jalan. Agar dapat memudahkan sistem pengamatan, maka dibutuhkan akselerometer yang terkalibrasi dan dikendalikan oleh mikrokontroler untuk merekam data vibrasi yang didapat dan disimpannya secara otomatis untuk mengevaluasi hasil dari perekaman. Pembuatan akselerometer ini menggunakan open source Arduino sebagai mikrokontroler sehingga sangat mudah untuk dibuat dan dikembangkan lebih lanjut untuk memajukan teknologi pengukuran vibrasi. Hasil pengukuran dari akselerometer ini langsung ditampilkan dalam layar LCD (Liquid Crystal Display) sehingga bisa dimonitor oleh pengamat.  Akselerometer yang dibuat memiliki rentang ukur sampai dengan 16 g dan prototipe akselerometer ini dikalibrasi menggunakan reference accelerometer B&K tipe 8305 nomor seri 1499872 dari Laboratorium Akustik dan Vibrasi Pusat Penelitian Metrologi-LIPI untuk rentang ukur sampai dengan 5 g dengan prosedur ISO 16063-21 sehingga nilai pengukurannya dapat terjamin kebenarannya. Hasil kalibrasi dalam rentang pengukuran sampai dengan 5 g dalam frekuensi sampai dengan 63 Hz menunjukan bahwa sensor akselerometer ini memiliki kemungkinan deviasi sampai 0.34g. Hasil perhitngan dan pengolahan data dari kalibrasi ini menghasilkan akurasi sebesar 98.4% pada frekuensi 31.5 Hz dan 40 Hz.
THE FUTURE OF POWER SEMICONDUCTOR DEVICES ROLE IN SMART GRID IMPLEMENTATION IN INDONESIA Supono, I; Ardiatna, W
Instrumentasi Vol 39, No 2 (2015)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (499.859 KB) | DOI: 10.14203/instrumentasi.v39i2.96

Abstract

The use of power semiconductor devices as interfaces of distributed power generators in the smart grid is the key justification for the device advancement. It is the important forthcoming energy scheme for Indonesia to overcome the national electrical power shortage. The study of semiconductor devices focuses on their application in circuit breaker based on power semiconductor device, (solid-state circuit breaker/SSCB), which is a key element for the safety system in the smart grid scheme. An investigation on several devices in the market recommends a power semiconductor device type to be promoted in the near future for this specified application. The associated standardization infrastructure for the future of power device research, development and manufacturing in Indonesia is also presented. This paper presents the benefit of strengthening the role of power semiconductor devices in the electrical energy sector in Indonesia. It also shows that the IGCT will be the most promising device to be implemented in circuit breakers for transmission and distribution system.
PERBANDINGAN ANTARA METODE HIDROTERMAL DAN METODE PENGADUKAN UNTUK PEMBUATAN GOETHITE DENGAN PARAMETER KEMURNIAN Kartika, Nadya Larasati; Nugroho, A. Agung
Instrumentasi Vol 39, No 2 (2015)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (882.978 KB) | DOI: 10.14203/instrumentasi.v39i2.95

Abstract

Struktur kristal goethite dapat berubah pada temperatur yang cukup rendah, seperti sedikit struktur hematite (α-Fe2O3) yang terbentuk pada temperatur 140oC. Pada penelitian ini, goethite (α-FeOOH) disintesis melalui dua metode, yaitu metode hidrotermal dan metode pengadukan. Hasil pengukuran difraksi X-ray dari kedua metode dibandingkan satu sama lain untuk mendapatkan metode sintesis yang paling optimal. Berdasarkan hasil fitting antara hasil pengukuran dan literatur melalui metode rietveld, metode pengadukan memiliki parameter kecocokan pola difraksi yang lebih baik dibandingkan metode hidrotermal. Metode pengadukan menghasilkan parameter GOF sebesar 3,8, sedangkan metode hidrotermal sebesar 122 akibat munculnya fase baru yang tumbuh, yaitu hematite (Fe2O3).
KETERSEDIAAN DAN KEBUTUHAN PERANGKAT UKUR NANO DI INSTITUSI PUSAT PENELITIAN ILMU PENGETAHUAN DAN TEKNOLOGI (PUSPIPTEK) Febrian, Rizki; Nugraha, Asep Ridwan; Pusaka, Jimmy
Instrumentasi Vol 39, No 2 (2015)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (520.642 KB) | DOI: 10.14203/instrumentasi.v39i2.94

Abstract

Secara luas, terminologi nanoteknologi berarti bidang sains dan rekayasa material di dalam rentang ukur nanometer (10-9 meter). Di dalam rentang ukur tersebut bisa diamati properti dari material yang selama ini tidak diketahui dalam rentang mikrometer–nanometer (μm–nm). Oleh karena itu, perangkat-perangkat ukur yang akurat pun dibutuhkan. Survei dilakukan melalui kuesioner tentang perangkat ukur pada institusi yang ada di kawasan Puspiptek dan lembaga metrologi nasional di negara lain sebagai informasi pembanding. Perangkat ukur dengan jumlah penggunaan yang tinggi di Puspiptek adalah scanning electron microscopy (SEM) sebesar 39,24%, X-ray diffraction (XRD) sebesar 14,75%, dan transmission electron microscopy (TEM) sebesar 14,12%. Digunakan pada kegiatan rekayasa presisi, elektronik, optik, dan ilmu bahan, perangkat ukur ini memiliki standar acuan berupa reference material berdasarkan cara kerja perangkat ukur tersebut.
PENGEMBANGAN HMI UNTUK SISTEM OTOMASI PENGOLAHAN AIR GAMBUT Muchlis, Imamul
Instrumentasi Vol 39, No 2 (2015)
Publisher : LIPI Press, Anggota IKAPI

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (891.796 KB) | DOI: 10.14203/instrumentasi.v39i2.93

Abstract

Human Machine Interface (HMI) adalah perangkat lunak antarmuka yang menjadi penghubung antara manusia dan mesin atau proses. Sistem proses yang otomatis tanpa HMI menyulitkan operator untuk mengetahui keadaan proses dan melaksanakan langkah-langkah segera untuk mengatasi setiap penyimpangan. Pada kegiatan penelitian kompetitif tahun 2014, HMI dibuat untuk sistem pengolahan air-gambut otomatis. Tahap pengembangan HMI pada personal computer meliputi teknik antarmuka pengguna secara grafis, pemrograman HMI dengan menetapkan tag elemen layar, integrasi ke dalam perangkat PLC menggunakan ethernet, dan uji coba HMI terhadap sistem pengolahan air-gambut otomatis. Hasil pembuatan HMI berupa visualisasi secara grafis di layar komputer tentang pengolahan air-gambut, status peralatan, dan variabel proses. Melalui layar HMI, operator dapat menjalankan dan menghentikan sistem pengolah serta mengatur parameter pengendalian. Adanya HMI membuat pengoperasian pengolahan air-gambut menjadi mudah, efisien, dan menyenangkan.