Reconnecting Sambungan Rumah (Sr) Pada Gardu 079 Sovia Untuk Mengurangi Losses Di PT PLN (Persero) Rayon Bukittinggi (Menggunakan Aplikasi Jaringan Syaraf Tiruan) Junaidi Asrul; Firmansyah firmansyah
Elektron : Jurnal Ilmiah Vol 6 No 1 (2014): Elektron Jurnal Ilmiah
Publisher : Teknik Elektro Politeknik Negeri Padang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (375.511 KB) | DOI: 10.30630/eji.6.1.61

Abstract

Dengan melakukan reconnecting dapat mengatasi rugi-rugi energi. Pada titik sambungan percabangan disambungan rumah sampai ke kWh meter digantikan dengan compression Connector. Terminal pada kWh meter sering terjadi loss kontak. Dengan sering terjadinya loss kontak, maka terminal pada kWh meter digantikan dengan menggunakan joint sleeve bimetal. Besarnya rugi jaringan disebabkan oleh penggunaan tap connector pada titik sambungan dan terminal pada kWh meter pelanggan. Digardu 079 Sovia area kerja PT. PLN (Persero) rayon Bukittinggi mengalami rugi kWh salur pada bulan desember 2013-januari 2014 sebesar 13 %. Setelah dilakukan reconnecting, rugi kWh salur menurun menjadi 4,48% pada bulan Mei 2014. Dengan menggunakan jaringan Syaraf Tiruan, dapat dilihat kinerja untuk rugi kWh salur setelah dilakukan reconnecting lebih baik.
Reduksi Harmonisa Pada Saluran Distribusi Tenaga Listrik Dengan Filter Daya Aktif Fitriadi .; M. Imran Hamid; Herisanjani Herisanjani; Firmansyah Firmansyah; Zulka Hendri
Elektron : Jurnal Ilmiah Volume 15 Nomor 1 Tahun 2023
Publisher : Teknik Elektro Politeknik Negeri Padang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30630/eji.15.1.350

Abstract

The large use of power converters in distribution lines causes poor power quality such as high produces harmonics in an electric power system that arises due to the operation of non-linear electrical equipment. The presence of harmonics in the power system distribution results in a very large loss in the system. In this paper had been done a simulation of power quality improvement through harmonic reduction using parallel active power filter. Active power filters work with control techniques based on the concept of instantaneous power to determine the amount of compensation currents that must be generated by the power compensator power circuit. The compensating current references generated by the control circuit are used by the hysteresis type controller to provide harmonic compensation arising. From the result of simulation using Simulink MATLAB, the harmonic value (THD) decrease caused by the 3 phase rectifier load on a distribution network which is used as case example. The harmonic value before compensated on the network is 27.85% at each phase, while after computing the harmonic value of the network decreases to 1,43% in R phase, 1,49% in S phase, and 1,34% in T phase.