DESAIN DAN ANALISIS KEKUATAN DUDUKAN (BRACKET) AC OUTDOOR MENGGUNAKAN METODE ELEMEN HINGGA Wibawa, Lasinta Ari Nendra
JURNAL CRANKSHAFT Vol 2, No 1 (2019): Jurnal Crankshaft
Publisher : Universitas Muria Kudus

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (561.906 KB) | DOI: 10.24176/crankshaft.v2i1.2688

Abstract

Penelitian ini mengkaji tentang perancangan dan analisis kekuatan dudukan AC outdoor menggunakan metode elemen hingga. Analisis dilakukan menggunakan software Autodesk Inventor Professional 2017. Variabel beban AC outdoor yang diterima oleh masing-masing dudukan AC yaitu 156,96; 176,58; 196,2 , dan 215,82 N. Hasil simulasi menunjukkan untuk berat AC Outdoor 156,96; 176,58; 196,2, dan 215,82 N memiliki faktor keamanan berturut-turut yaitu 2,559; 2,275; 2,047, dan 1,861.
PENGARUH BEBAN TERHADAP PREDIKSI UMUR FATIK DUDUKAN (BRACKET) AC OUTDOOR MENGGUNAKAN METODE ELEMEN HINGGA LASINTA ARI NENDRA WIBAWA
JURNAL CRANKSHAFT Vol 3, No 1 (2020): Jurnal Crankshaft Vol.3 No.1 Maret 2020
Publisher : Universitas Muria Kudus

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24176/crankshaft.v3i1.4320

Abstract

The study examines the effect of the load on fatigue life prediction of an outdoor AC bracket using the finite element method. Outdoor AC bracket design uses Autodesk Inventor Professional 2017, while finite element analysis uses Ansys Workbench. The outdoor AC bracket is subjected to a load of 20, 25, 30, and 35 kg with a fully-reserved type of loading. Gerber's mean stress theory is used to predict fatigue life. The outdoor AC bracket material uses Aluminum alloy 5052. The simulation results show that the outdoor AC bracket has a minimum fatigue life for loads of 20, 25, 30, and 35 kg, respectively is 1 x 108, 1.49 x 107, 1.93 x 106, and 6.64 x 105 cycles. Whereas the safety factor for minimum fatigue life for loads of 20, 25, 30, and 35 kg is 1.65; 1.32; 1.10; and 0.58. It shows the outdoor AC bracket can withstand the fatigue life of up to a minimum of 106 cycles for loads of 20, 25, and 30 kg because it has a safety factor of more than 1. While the 35 kg load of outdoor AC bracket fails to reach a minimum fatigue life of 106 cycles due to fatigue life prediction is only reached 6.64 x 105 cycles with a safety factor of less than 1, which is 0.58.
DESAIN DAN ANALISIS KEKUATAN DUDUKAN (BRACKET) AC OUTDOOR MENGGUNAKAN METODE ELEMEN HINGGA Lasinta Ari Nendra Wibawa
JURNAL CRANKSHAFT Vol 2, No 1 (2019): Jurnal Crankshaft Vol.2 No.1 Maret 2019
Publisher : Universitas Muria Kudus

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24176/crankshaft.v2i1.2688

Abstract

Penelitian ini mengkaji tentang perancangan dan analisis kekuatan dudukan AC outdoor menggunakan metode elemen hingga. Analisis dilakukan menggunakan software Autodesk Inventor Professional 2017. Variabel beban AC outdoor yang diterima oleh masing-masing dudukan AC yaitu 156,96; 176,58; 196,2 , dan 215,82 N. Hasil simulasi menunjukkan untuk berat AC Outdoor 156,96; 176,58; 196,2, dan 215,82 N memiliki faktor keamanan berturut-turut yaitu 2,559; 2,275; 2,047, dan 1,861.