Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : Lontara: Journal of Health Science and Technology

Perbedaan Derajat Osteoartritis Sendi Lutut pada Hasil Radiografi Posisi AP Supine dan AP Erect di Instalasi Radiologi Rumah Sakit Akademis Jaury Jusuf Putera Makassar A.AR.Rakhmansya Iskandar; Rusman Achmad; Imran Amin
Lontara Journal of Health Science and Technology Vol 1 No 1 (2020): Ilmu dan Teknologi Kesehatan
Publisher : Lembaga Penelitian dan Pengabdian Masyarakat Politeknik Kesehatan Muhammadiyah Makassar

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53861/lontarariset.v1i1.27

Abstract

Osteoarthritis is a degenerative joint disease that is associated with damage to joint cartilage. One way to diagnose mild pain or the onset of OA early is to do a rontgen examination. The aim of the study was to determine the differences in the degree of osteoarthritis of the knee joint AP position erect with the AP supine position. This research was conducted in the hospital. Academic Jaury Jusuf Putera Makassar April - June 2019. This type of research is descriptive analytical, data collection techniques using questionnaires, sampling techniques carried out by accidental sampling analysis. Data analysis using statistics Presentation of data is presented in the form of graph tables accompanied by narration. Based on the results of the study it can be concluded that the Erect Position has an assessment score with an average of 7.20 while the Supine position with an average of 8.00. From the results of the statistical test obtained p value (0.455)> 0.05 means that there is no statistically significant difference in scores between Erect and Supine positions. It is expected that the radiology officer chooses the right projection that is in accordance with the patient's general condition. If it is possible for the patient to be examined with the projection of AP Weight-Bearing Standing, the officer uses the projection, otherwise the officer can use the AP Supine or AP Erect position because the two positions have no significant differences based on the results of the existing research.
Efektivitas Rancang Bangun Alat Fiksasi Pada Pemeriksaan Os Femur Di Instalasi Radiologi RSUD H. Padjonga Dg. Ngalle Takalar A.AR.Rakhmansya Iskandar; Nurbeti Salam; Yusran Basra
Lontara Journal of Health Science and Technology Vol 1 No 1 (2020): Ilmu dan Teknologi Kesehatan
Publisher : Lembaga Penelitian dan Pengabdian Masyarakat Politeknik Kesehatan Muhammadiyah Makassar

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53861/lontarariset.v1i1.33

Abstract

Radiology Fixation Tool is a tool made from a specially designed iron plate which is expected to be able to function which contains a report that can be used by the radiologist who handles patients with a femur pryection examination table for non-cooperative patients. This study was designed to obtain information about os femur fixation design assistance in the Radiology Installation of H. Padjonga Regional Hospital, Ngalle Takalar, to obtain information about fixation devices that are made very effective or effective for tool design, patient care, and required radiographic results. This research was conducted in April - May 2019. The type of this research is Deskritiptif where the population and samples that are the object of this research come from radiology radiographers at RSUD H. Padjonga Dg. Ngalle Takalar as many as 8 respondents Based on the results of data collection using a questionnaire in the Radiology Installation of H. Padjonga Hospital in Ngalle Takalar in terms of the Design Tools Obtained results of 100 percent or according to the excellent category of this tool, it is very easy, easy and easy to use for users. For aspects of the Patient Acceptance aspect, the results are 95 percent or in a very good category. While for the Radiographic Results aspect, the results obtained are 75 percent or in the Good category. Preferably the procurement of radiological fixation devices is a necessity. With a fixation tool, it can reduce image sharpness due to movement / thus helping radiographers to produce high quality photos.