Jurnal Perangkat Nuklir
Vol 8, No 1 (2014): Juni 2014

PENENTUAN JARAK MINIMUM ANTAR CARRIER YANG BERURUTAN DI LINTASAN GERAK PADA IRADIATOR GAMMA IR-200 K

Achmad Suntoro (PRFN -BATAN)



Article Info

Publish Date
24 Mar 2015

Abstract

PENENTUAN JARAK MINIMUM ANTAR CARRIER YANG BERURUTAN DI LINTASAN GERAK PADA IRADIATOR GAMMA IR-200 K. Desain untuk menentukan jarak minimum antar carrier pada lintasan instalasi iradiator gamma IR-200K dilakukan. Kesetimbangan antara gaya sentrifugal dari carrier pada lintasan melingkar dan gaya beratnya serta dimensi dari carrier digunakan sebagai parameter dalam menentukan jarak minimum tersebut. Ditetapkan jarak minimum antar carrier dalam desain 1.2 meter. Jarak ini 11.5% lebih besar dari jarak minimumantar carrier menurut perhitungan teoritis yaitu 1.076 meter. Toleransi kesalahan dalam konstruksi/instalasi lintasan serta hal lain tak terduga dalam operasi menjadi pertimbangan untuk memperbesar jarak tersebut dari nilai teoritisnya. Kondisi ini tidak akan mempengaruhi throuhput dan efisiensi penggunaan radiasi karena pada segmen lintasan yang lurus tidak perlu mengikuti jarak minimum antar carrier ini, karena segmen lintasan carrier disekitar sumber radiasi lurus.Katakunci: jarak antar carrier, iradiator gamma, kesetimbangan gaya, jarak minimum.MINIMUM DISTANCE DETERMINATION BETWEEN CONSECUTIVE CARRIERS IN THEGAMMA IRRADIATOR IR-200 K TRAJECTORY. A design to determine the minimum distance between the consecutive carriers at the trajectory of gamma irradiators IR-200K is implemented. Equilibrium between centrifugal force of a moving carrier in circular trajectory and its gravity force as well as carrier dimensions are used as parameters in determining such a minimum distance. The minimum distance between the consecutive carriers in the design is defined 1.2 meters. The distance is 11.5% greater than the minimum distance theoretically calculated, namely 1,076 meters. Errors tolerance in construction/installation of the trajectory and other unexpected things during irradiator’s operation are part of the consideration to enlarge the minimum distance from itstheoretical value. The distance between the consecutive carriers will not affect throuhput and efficiency of using radiation due to the straight trajectory segments do not need to follow such the minimum distance between the carriers, as the trajectory segments around the iradiation sources are straight.Keyword: distance between carriers, gamma irradiator, equilibrium forces, minimum distance.

Copyrights © 2014






Journal Info

Abbrev

jpn

Publisher

Subject

Energy

Description

Jurnal Perangkat Nuklir (Journal of Nuclear Equepments), terbit dua kali setiap tahun bulan Mei dan November sejak 2007. Partisipasi aktif berupa saran dan pendapat maupun kritik yang bersifat membangun sangat diharapkan untuk meningkatkan kualitas jurnal. Alamat: Gedung 71, Kawasan Puspiptek ...