Jurnal Imejing Diagnostik
Vol 7, No 1: JANUARY 2021

Analisis Variasi Flip Angle terhadap Informasi Citra Anatomi pada Sekuen 3D TOF MRA Brain dengan MRI 3 Tesla

Fatimah Fatimah (Jurusan Teknik Radiodiagnostik dan Radioterapi Poltekkes Kemenkes Semarang, Indonesia)
Dwi Rochmayanti (Jurusan Teknik Radiodiagnostik dan Radioterapi Poltekkes Kemenkes Semarang, Indonesia)
Fina Kristianti (Jurusan Teknik Radiodiagnostik dan Radioterapi Poltekkes Kemenkes Semarang, Indonesia)



Article Info

Publish Date
02 Feb 2021

Abstract

Background : Magnetic Resonance Angiography is a diagnostic imaging method that can display images of blood vessels. MRA imaging on MRI 3 Tesla provides high spatial resolution making blood vessel contrast increased so that the intracranial vessels are clearer. The efficient technique that does not use contrast media in MRA is Time of Flight. 3D TOF imaging is good for visualizing intracranial vessels. In this method the appropriate flip angle will produce a hyperintense picture of the blood vessels. This study aims to determine the effect of flip angle on anatomical image information on 3D TOF MRA Brain.Methods : This type of research is a quantitative experimental approach, conducted in February 2020 in Pertamina Central Hospital, South Jakarta. Research by conducting flip angle variations of 15°, 20°, 25°, 30° in the 3D TOF sequence of the Brain against 10 volunteers. Criteria for volunteers are healthy people aged 18-25 years. The results of the images were assessed by 3 respondent, including Internal Carotid Artery, Vertebral Artery, Basilar Artery, Anterior Cerebral Artery, Posterior Cerebral Artery, Middle Cerebral Artery, Anterior Communicating Artery, Posterior Communicating Artery. Then the Kappa test was carried out followed by the Friedman test to find the highest mean rank and comparison of flip angle in anatomical information of 3D TOF MRA Brain.Results : The results showed that there was an effect of changes in the values of the flip angle to the anatomical information on 3D TOF MRA Brain with p 0,05. The optimal Flip angle value is obtained based on the highest mean rank value which is flip angle 25° with a value of 3,22. The higher the value of flip angle, the greater the signal and contrast, but many slow flowing blood vessels will hypointens.Conclussion : There are difference in anatomical image information of 3D TOF sequence among 4 variation flip angle on examination MRA Brain. Flip angle 25° is better than 15°, 20° and 30° at anatomy information on 3D TOF sequences to show intracranial artery because it has a higher mean rank value. 

Copyrights © 2021






Journal Info

Abbrev

jimed

Publisher

Subject

Health Professions Medicine & Pharmacology

Description

Jurnal Imejing Diagnostik (JImeD) memuat tulisan ilmiah dalam bidang radiologi berupa hasil penelitian dan non penelitian (konseptual). Jurnal Imejing Diagnostik (JImeD) terbit 2 kali dalam satu tahun yaitu pada bulan Januari dan Juli oleh Jurusan Teknik Radiodiagnostik dan Radioterapi, Politeknik ...