Jurnal Teknologi dan Sistem Komputer
Volume 9, Issue 2, Year 2021 (April 2021)

Sistem sensor untuk pemantauan kadar oksigen terlarut berbasis galvanik pada kolam budidaya ikan air tawar

Damar Wicaksono (Department of Computer Engineering, Universitas Nahdlatul Ulama Yogyakarta. Jl. Lowanu No.47, Sorosutan, Kec. Umbulharjo, Daerah Istimewa Yogyakarta 55162|Universitas Nahdlatul Ulama Yogyakarta)
Tatag Lindu Bhakti (Department of Computer Engineering, Universitas Nahdlatul Ulama Yogyakarta. Jl. Lowanu No.47, Sorosutan, Kec. Umbulharjo, Daerah Istimewa Yogyakarta 55162|Universitas Nahdlatul Ulama Yogyakarta)
Restiadi Bayu Taruno (Department of Computer Engineering, Universitas Nahdlatul Ulama Yogyakarta. Jl. Lowanu No.47, Sorosutan, Kec. Umbulharjo, Daerah Istimewa Yogyakarta 55162|Universitas Nahdlatul Ulama Yogyakarta)
Melvin Rahma Sayuga Subroto (Department of Computer Engineering, Universitas Nahdlatul Ulama Yogyakarta. Jl. Lowanu No.47, Sorosutan, Kec. Umbulharjo, Daerah Istimewa Yogyakarta 55162|Universitas Nahdlatul Ulama Yogyakarta)
Anita Mustikasari (Department of Management, Universitas Negeri Yogyakarta. Jl. Colombo Yogyakarta No.1, Caturtunggal, Kec. Depok, Daerah Istimewa Yogyakarta 55281|Universitas Negeri Yogyakarta)



Article Info

Publish Date
30 Apr 2021

Abstract

This study aims to develop low-cost and environmentally friendly material galvanic-based dissolved oxygen sensors. A Dissolved oxygen (DO) sensor has been designed and fabricated on an 85 x 205 mm galvanic-based. The sensor structure device consists of Al-Zn reference layer electrode, Ag/AgCl active electrode, 120ml KCl electrolyte solvent 0,1 M, and closed by TiO2 membrane (PTFE). The Al-Zn formation reference electrode was done by Ag layer chlorination using FeCl3, and the TiO2 membrane was formed by TiO2 paste screen printing. The test was done to measure the sensor’s performance based on the current-voltage characteristics between 1.0 and 1.8 V. The results showed that a stable diffusion current was obtained when the input voltage was 1.5 V, resulting in the best sensor performance with a sensitivity of 0.7866 μA L/mg and a stable step response time of 3 mins. This prototype sensor showed high potential for prototyping for a low-cost water quality monitoring system.

Copyrights © 2021






Journal Info

Abbrev

JTSISKOM

Publisher

Subject

Computer Science & IT Electrical & Electronics Engineering

Description

Jurnal Teknologi dan Sistem Komputer (JTSiskom, e-ISSN: 2338-0403) adalah terbitan berkala online nasional yang diterbitkan oleh Departemen Teknik Sistem Komputer, Universitas Diponegoro, Indonesia. JTSiskom menyediakan media untuk mendiseminasikan hasil-hasil penelitian, pengembangan dan ...