Pengaruh Setting Tap Transformator Terhadap Profil Tegangan Pada Jaringan IEEE 14 Bus

Radiktyo Nindyo Sumarno (Universitas Muhammadiyah Semarang)
Laily Muntasiroh (Universitas Muhammadiyah Semarang)
Dina Mariani (Universitas Muhammadiyah Semarang)



Article Info

Publish Date
14 Jul 2022

Abstract

Adanya jarak yang jauh dari pusat pembangkit ke beban pada sistem penyaluran tenaga listrik menyebabkan profil tegangan pada sisi terima atau sisi konsumen kadang turun kualitas tegangannya. Salah satu dari penurunan kualitas tegangan adalah penurunan level tegangan. Standar penurunan level tegangan pada setiap negara berbeda-beda tetapi secara umum penurunan level tegangan yang diijinkan kurang lebih tidak boleh lebih dari 10%. Tujuan penelitian ini adalah mengetahui pengaruh setting tap pada transformator untuk mengoptimalkan penurunan level tegangan pada sisi terima atau pada sisi konsumen. Dengan setting tap transformator diharapkan memperbaiki aliran daya dan profil tegangan pada masing-masing bus. Profil tegangan tidak hanya dipengaruhi oleh nilai setting tap transformator saja, tetapi bentuk dari jaringan juga berpengaruh. Hasil penelitian ini adalah dengan mengubah setting tap transformator dapat menghasilkan perubahan aliran daya dan profil tegangan. Setting tap yang paling optimal didapatkan pada nilai yang optimal, bukan nilai tap transformator yang semakin kecil atau semakin besar nilainya. Rata-rata penurunan level tegangan paling kecil diantara 3 skenario yang diterapkan didapatkan hasil yaitu rata-rata penurunan sebesar 5,137 % pada skenario dengan tap setting 0,95.  The long distance from the power plant to the load on the electric power distribution system causes the voltage profile on the receiving side or the consumer side to sometimes decrease the quality of the voltage. One of the decrease in the quality of the voltage is a drop voltage. The standard drop in voltage level varies from country to country but in general the allowable drop in voltage level should not be more than 10%. The purpose of this study was to determine the effect of setting tap on the transformer to optimize the voltage level drop on the receiving side or on the consumer side. By setting the tap transformer, it is expected to improve the power flow and voltage profile on each bus. The voltage profile is not only affected by the transformer tap setting value, but the shape of the network also has an effect. The result of this research is that changing the transformer tap settings can result in changes in the power flow and voltage profile. The most optimal tap setting is obtained at the optimal value, not the smaller the transformer tap value or the larger the value. The smallest average drop voltage level among the 3 scenarios applied, the results obtained are an average decrease of 5.137% in the scenario with a tap setting of 0.95. 

Copyrights © 2022






Journal Info

Abbrev

jjeee

Publisher

Subject

Computer Science & IT Control & Systems Engineering Electrical & Electronics Engineering Energy Engineering

Description

Jambura Journal of Electrical and Electronics Engineering (JJEEE) is a peer-reviewed journal published by Electrical Engineering Department Faculty of Engineering, State University of Gorontalo. JJEEE provides open access to the principle that research published in this journal is freely available ...