Indonesian Journal of Physics (IJP)
Vol 31 No 1 (2020): Vol 31 No 1 (2020)

Measurement of Oxygen Concentration in Static and Flowing Liquid Pb-Bi by Using Zirconia Based Sensor

Pribadi Mumpuni Adhi (Department of Mechanical Engineering, Politeknik Negeri Jakarta, Jl. Prof. G. A. Siwabessy, Kampus UI, Depok 16425, INDONESIA)
Dianta Mustofa Kamal (Department of Mechanical Engineering, Politeknik Negeri Jakarta, Jl. Prof. G. A. Siwabessy, Kampus UI, Depok 16425, INDONESIA)
Muslimin Muslimin (Department of Mechanical Engineering, Politeknik Negeri Jakarta, Jl. Prof. G. A. Siwabessy, Kampus UI, Depok 16425, INDONESIA)
Andrei Vilcu (Politechnica University of Bucharest, Str. Splaiul Independentei nr 313, District 6, Bucharest, 060042 ROMANIA)
Masatoshi Kondo (Laboratory for Advanced Nuclear Energy, Institute Innovative Research, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo, 152-8550, JAPAN)
Minoru Takahashi (Laboratory for Advanced Nuclear Energy, Institute Innovative Research, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo, 152-8550, JAPAN)



Article Info

Publish Date
21 Jan 2020

Abstract

Liquid Lead-Bismuth Eutectic (LBE) has been proposed as one of the coolant for the Generation IV nuclear reactor. However, the oxygen should be controlled adequately to suppress the corrosion rate of the LBE. A device called oxygen sensor made of zirconia as solid electrolyte has been used to monitor the oxygen concentration online in order to control the oxygen concentration. The principle of this sensor is based on electrochemistry method where the difference oxygen activitiy between reference electrode (RE) and working electrode (in liquid LBE) can make potential difference. The potential difference is measured by electrometer and can be converted into oxygen concentration based on Nernst equation. Iron (Fe)/Magnetite (Fe3O4) was used as material for RE in this study. Measurement of oxygen concentration was conducted at 450 - 600°C for the static condition of LBE and around 390°C for the dynamic condition of flowing LBE. The oxygen concentration for both two experiment conditions were set in oxygen saturated condition of Pb-Bi. The oxygen sensor based on zirconia solid electrolyte with Fe/Fe3O4 as RE can measured the oxygen concentration in liquid LBE. The results showed that the measurement was agreed with the Nernst equation theoretical calculation.

Copyrights © 2020






Journal Info

Abbrev

ijp

Publisher

Subject

Astronomy Computer Science & IT Earth & Planetary Sciences Electrical & Electronics Engineering Energy Engineering

Description

Indonesian Journal of Physics welcomes full research articles in the area of Sciences and Engineering from the following subject areas: Physics, Mathematics, Astronomy, Mechanical Engineering, Civil and Structural Engineering, Chemical Engineering, Electrical Engineering, Geotechnical Engineering, ...