Indonesian Journal of Cancer
Vol 17, No 1 (2023): March

Comparison of Electrons and Photons Treatment Plans in Medulloblastoma Patients

Muhammad Usman Ghani (Bannu Institute of Nuclear Medicine Oncology And Radiotherapy (BINOR), Bannu)
Aasia Razzaq (Institute of Nuclear Medicine and Oncology (INMOL) Hospital, Lahore)
Nauman Amjad (Institute of Nuclear Medicine and Oncology (INMOL) Hospital, Lahore)
Ismat Fatima (Institute of Nuclear Medicine and Oncology (INMOL) Hospital, Lahore)



Article Info

Publish Date
28 Mar 2023

Abstract

Background: The treatment of medulloblastoma involves surgery, radiotherapy, and adjuvant chemotherapy. In radiotherapy, craniospinal irradiation (CSI) is prescribed, where two lateral cranial fields and one or two spinal beams are applied in CSI. Different multi-field techniques (coplanar and/or noncoplanar) are used to register the prescribed dose. The purpose of this study was to assess plan quality in terms of dose coverage of the spine with both photon and electron beam therapy and the sparing of organs at risks (OARs).Methods: Ten pediatric patients (ages 6 to 10 years) were immobilized in the prone position for simulation. The Clinical Target Volume (CTV) of the organ under treatment, Planning Target volume (PTV) of the organ under treatment, and OARs were contoured. Prowess Panther (v4.71) was used for dose computations. Two lateral parallel-opposed 6 MV photon cranial fields with the spinal beam(s) (either 6 Photons or 21 MeV electrons) were used in planning. Electron beams were added posteriorly on the spine with parallel-opposed cranial fields. The treatment plans were computed for 3600 c Gy in 21 fractions.Results: For comparable conformity number of electron versus photons beam plans (0.68 ± 0.41 versus 0.66 ± 0.47, is not significantly different at p < 0.05) and homogeneity index (1.22 ± 0.03 versus 1.25 ± 0.04, is significantly different at p < 0.05), the photon doses were higher for underlying OARs (heart, liver, and thyroid) and were lower for partially in-field organs (lungs and kidneys) compared to electrons.Conclusions: The underlying organs i.e., thyroid, heart, and liver receive a lesser dose in case of electrons, while partially in-field organs are exposed more compared to photons mainly due to the ballooning effect in electrons. The study shows that both electrons and photons can be used for CSI. However, the electron may be preferred due to its better sparing of underlying structures.

Copyrights © 2023






Journal Info

Abbrev

ijoc

Publisher

Subject

Biochemistry, Genetics & Molecular Biology Immunology & microbiology Medicine & Pharmacology Public Health

Description

Indonesian Journal of Cancer is a peer-reviewed and open-access journal. This journal is published quarterly (in March, June, September, and December) by Dharmais Cancer Hospital - National Cancer Center. Submissions are reviewed under a broad scope of topics relevant to experimental and clinical ...