Jurnal Ilmu Pertanian Indonesia
Vol. 28 No. 4 (2023): Jurnal Ilmu Pertanian Indonesia

Keamanan Mikrobiologis Air Minum Isi Ulang dan Perubahannya Selama Penyimpanan

Tasya Fitri Yunada (Sekolah Pascasarjana, Program Studi Ilmu Pangan, IPB University, Kampus IPB Darmaga, Bogor 16680)
Winiati Pudji Rahayu (Departemen Ilmu dan Teknologi Pangan, Fakultas Teknologi Pertanian, Kampus IPB Darmaga, Bogor 16680
South-East Asia Food and Agricultural Science and Technology (SEAFAST) Center LPPM IPB, Kampus IPB Darmaga, Bogor 16680)

Dian Herawati (Departemen Ilmu dan Teknologi Pangan, Fakultas Teknologi Pertanian, Kampus IPB Darmaga, Bogor 16680
South-East Asia Food and Agricultural Science and Technology (SEAFAST) Center LPPM IPB, Kampus IPB Darmaga, Bogor 16680)



Article Info

Publish Date
16 Jun 2023

Abstract

Indonesians use refilled drinking water which can be obtained at depots because of practical and affordable reasons. Low levels of sanitation and hygiene and storage of refilled drinking water for an extended period can lead to the possibility of the growth of indicator and pathogenic microorganisms such as Coliform and Escherichia coli (E. coli). This study aims to evaluate the application of drinking water refilling stations (DWRS) sanitary hygiene, microbiological quality and safety of refilled drinking water and its changes during storage. Samples of refilled drinking water were taken from two DWRSs for each region in five areas of DKI Jakarta including West, East, South, North, and Central Jakarta. The treatments in this study were refilled drinking water storage in gallons of closed and open-closed conditions at room temperature (28 + 2°C) for 0, 7, and 14 days. The results of observations showed that 30% (n=30) of depots complied with hygiene sanitation standards according to Permenkes RI No. 43 of 2014 (>70%). The analysis results showed that refilled drinking water at 0 days of storage, 100% met the TPC (5 Log CFU/mL), 20% met the total Coliform standard (0 Log CFU/mL), and 80% met the E. coli standard (0 Log CFU/mL) according to Permenkes RI No. 492 of 2010. Storage times of 0, 7, and 14 days of refilled drinking water had a significant effect on TPC and total Coliform (P < 0.05), but had no significant effect on E. coli (P > 0.05) in gallons with closed and open-closed conditions. Keywords: Coliform, DWRS, E. coli, refilled drinking water

Copyrights © 2023






Journal Info

Abbrev

JIPI

Publisher

Subject

Agriculture, Biological Sciences & Forestry

Description

Artikel yang dimuat meliputi hasil-hasil penelitian, analisis kebijakan, dan opini-opini yang berhubungan dengan pertanian dalam arti luas, seperti agronomi, ilmu tanah, hama dan penyakit tanamam, ilmu kehewanan, kedokteran veteriner, keteknikan pertanian, teknologi industri, teknologi pangan, ilmu ...