ANALISA BEBAN PENDINGIN PRODUK PADA CONTACT PLATE FREEZER TERHADAP KINERJA KOMPRESOR DI PT. TRIMITRA MAKMUR, TARAKAN, KALIMANTAN UTARA

Samsi Samsi (Politeknik Ahli Usaha Perikanan)
Ade Hermawan (Politeknik Ahli Usaha Perikanan)
Teguh Binardi (Politeknik Ahli Usaha Perikanan)
M. Ilham (Politeknik Ahli Usaha Perikanan)
Istianto Budhi Rahardja (Politeknik Kelapa Sawit Citra Widya Edukasi Bekasi)



Article Info

Publish Date
30 Aug 2023

Abstract

Contact plate freezer (CPF) is a refrigeration machine unit to freeze products that will certainly maintain product freshness. The cooling system is running smoothly, one thing that should be noted is the cooling load on the contact plate freezer. Cooling load is the amount of heat absorbed per unit of time. Refrigeration cycle at PT. Trimitra Makmur, using a combined refrigeration cycle (multi-stage cycle), using two vapor compression cycles using two single-stage compressors. The two compressors used have the same power of 55.92 kW. As for the main components of the refrigeration system at PT. Trimitra is prosperous, among others: Compressors, condensers, expansion valves, and evaporators. The cooling load on the contact plate freezer consists of product heat load, water heat load, internal heat load, and transmission heat load. In the contact plate freezer, the load of infiltration or heat from the outside air is not calculated because at the time of production the door of the contact plate freezer is closed tightly so the value of air exchange is very small and can be ignored. In this research, it was found that the average total load on contact plate freezer 1 was 23.07079 kW, so that the average total load on all three contact plate freezers at PT. Trimitra Makmur is 69.21237 kW. From the results of data collection and calculation, the COP value in the high-stage cycle is 4.33, so the power of the high-stage compressor used is 1/4.33 of the cooling capacity of the contact plate freezer. While in the booster cycle, a COP value of 6.49 is obtained, so the booster compressor power used is equal to 1/6.49 of the cooling capacity of the contact plate freezer.

Copyrights © 2023






Journal Info

Abbrev

jurtek

Publisher

Subject

Civil Engineering, Building, Construction & Architecture Computer Science & IT Engineering

Description

This journal is a scientific journal to develop knowledge in the field of Engineering & Technology. Editors invite professionals from education and researcher to write about the progress of science in the field of Engineering & Technology. The journal is published 2 (two) times in 1 year. ...