Ophthalmologica Indonesiana
Vol 49 No S2 (2023): Supplement Edition

AGREEMENT OF MELBOURNE RAPID FIELDS PERIMETRY PARAMETERS TO HUMPHREY FIELD ANALYZER IN MODERATE-SEVERE GLAUCOMA PATIENTS: RELATIONSHIP BETWEEN VISUAL ACUITY AND MELBOURNE RAPID FIELDS ACCURACY: Oral Presentation - Observational Study - Resident

Yuri Dwi Mayasari (Unknown)
Virna Dwi Oktariana (Unknown)
Dewi Yunia Fitriani (Unknown)



Article Info

Publish Date
08 Apr 2024

Abstract

Introduction & ObjectivesPerimetric examination is vital for measuring visual field defects and predicting the progression ofglaucoma. The Covid-19 pandemic prompted the use of perimetry at home. Tablet or website-basedperimetry becomes an option due to unavailability of Humphrey Field Analyzer (HFA). MelbourneRapid Fields (MRF) is affordable, portable and reliable, even provide the same benefits as HFA. Thisstudy aimed to assess the agreement of MRF results to HFA in moderate-severe glaucoma patientswith impaired visual acuity. MethodsObservational study using a cross-sectional design to assess the relationship between visual acuityand the agreement of MRF vs HFA in moderate-severe glaucoma patients. Subjects were groupedinto two groups based on visual acuity. Each subject was examined with MRF and HFA, the order ofexamination was randomized using block randomization. ResultsThe test durations were shorter on MRF than HFA (265.7±26.6 vs 384.4±46.7, P<0.001). There wasno significant difference in the reliability index of the two perimetry. MRF showed a high level ofconcordance in its outcomes with HFA (R=0.931, intraclass correlation coefficient (ICC)=0.957 formean defect (MD) and R=0.941, ICC=0.974 for Visual Field Index (VFI)). MRF also showed levels oftest-retest repeatability comparable to HFA (R=0.948, ICC=0.989 for MD and R=0.946, ICC=0.989for Visual Capacity (VC)). There was no correlation between visual acuity and MRF accuracy,p>0.05. ConclusionThe perimetry results from MRF have a very stong correlation to the HFA outcomes. MRF also hastest-retest repeatability comparable to HFA. The accuracy of the MRF results does not correlate withvisual acuity.

Copyrights © 2023






Journal Info

Abbrev

journal

Publisher

Subject

Health Professions Medicine & Pharmacology Public Health

Description

Ophthalmologica Indonesiana is an open accessed online journal and comprehensive peer-reviewed ophthalmologist journal published by the Indonesian Ophthalmologist Association / Perhimpunan Dokter Spesialis Mata (PERDAMI). Our main mission is to encourage the important science in the clinical area of ...