al Kimiya : Jurnal Ilmu Kimia dan Terapan
Vol 11, No 1 (2024): al Kimiya: Jurnal Ilmu Kimia dan Terapan

Urine Glucose Detection Via Gold Nanoparticle Formation Using 3D-Connector Microfluidic Paper Based Analytical Devices

Krista Firdaus Suwarno Putri (Department of Chemistry, Faculty of Mathematics and Natural Science, Universitas Brawijaya)
Hermin Sulistyarti (Department of Chemistry, Faculty of Mathematics and Natural Science, Universitas Brawijaya)
Akhmad Sabarudin (Department of Chemistry, Faculty of Mathematics and Natural Science, Universitas Brawijaya)



Article Info

Publish Date
01 Aug 2024

Abstract

A metabolic disorders that have experienced a significant increase in the world are diabetes mellitus. Diabetes is caused by two main factors: the first is damage to pancreatic beta cells, which prevents insulin from being produced, and the second is impaired insulin secretion and function. Chronic diabetes, if not treated properly, can lead to acute complications including eye, kidney, lung, nerve, and even death. Diabetes can be diagnosed through blood and urine. In general, glucose detection is carried out using invasive methods that use blood samples, which can cause pain and discomfort for users. Current research is developing non-invasive glucose detection using urine samples. This research aims to develop non-invasive glucose detection technology using 3D-connector μPADs (Microfluidic Paper Based Analytical Devices) which have the advantages of being safe, easy, and simple. The three-dimensional connector on the device functions as a connector to facilitate the coordination of fluid flow in the sample zone and detection zone. The glucose detection method uses gold (III) chloride as a gold nanoparticle (AuNPs) precursor, an aqueous extract of Acalypha indica Linn as a stabilizing agent, sodium hydroxide (NaOH) as a catalyst, and glucose in artificial urine as a sample. Method validation results using imageJ software indicated linearity with a coefficient of determination value (R2) of 0.9714, precision with a %RSD value (Relative Standard Deviation) of 2.69, and an accuracy level ranging from 92.22-99.23%.

Copyrights © 2024






Journal Info

Abbrev

ak

Publisher

Subject

Biochemistry, Genetics & Molecular Biology Chemical Engineering, Chemistry & Bioengineering Chemistry

Description

The scope of al Kimiya Jurnal Ilmu Kimia dan Terapan s publication included general studies and special studies The general studies are pure chemistry in general and in specific fields as follows Study of inorganic organic and biochemical substances materials that have traditionally been ...