Majalah Ilmiah Teknologi Elektro
Vol 22 No 2 (2023): (Juli - Desember) Majalah Ilmiah Teknologi Elektro

Perbaikan Jaringan Tegangan Rendah Dengan Sisip Trafo Distribusi Fase Tunggal Untuk Mengurangi Overload dan Jatuh Tegangan PT PLN (Persero) ULP Yogyakarta Kota

Muhammad Dwi Cahyo Ramadhan (Unknown)
Nina Loenca Br Ginting (Unknown)
Haidar Nabil Muflih (Unknown)
Nur Risya Difa Kusuma Ningrum (Unknown)
Candra Febri Nugraha (Unknown)



Article Info

Publish Date
24 Jan 2024

Abstract

Distribution transformers play a crucial role in the distribution network by transforming electrical energy from the source to the customers. This is closely related to issues in the process of distributing electrical energy. According to PLN standards, a transformer is considered overloaded when the load exceeds 80% of its installed capacity. Overloading can lead to increased transformer temperature, potentially damaging the insulation and causing power supply disruptions to consumers. A B&D 50kVA distribution transformer has been installed on pole 17A/U3-30 in the Belibis Street, Wonocatur, Banguntapan, Yogyakarta area. The transformer is currently experiencing a load of 112.5%. In this study, the insertion of an additional transformer is proposed as a solution to reduce the overload percentage and voltage drop. The transformer insertion has already been implemented in the field, and this study aims to analyze its impact by determining the optimal location through simulations. Based on the simulation results using ETAP 12.6.0, the transformer insertion on pole 1/S3-19 in the field can improve the voltage value at the customer end to 0.94 p.u., with a load of 86.6% on the inserted transformer and 35.6% on the existing transformer. However, an optimal location determination is found on pole 18/S3-17 based on the best voltage value at the customer end, which is 0.94 p.u., with the existing transformer operating at 58.1% load and the inserted transformer operating at 65.3% load. The inserted transformer can effectively reduce overload and voltage drop for customers, and by determining the optimal location, it can enhance the efficiency of analyzing load development and voltage values. Keywords— transformer; overload; drop voltage; ETAP; optimal

Copyrights © 2023






Journal Info

Abbrev

mite

Publisher

Subject

Computer Science & IT Control & Systems Engineering Electrical & Electronics Engineering Energy Engineering

Description

Majalah Ilmiah Teknologi Elektro (MITE) is peer review journal, published twice a year by the Study Program of Magister Electrical Engineering, Faculty of Engineering, Universitas Udayana. This journal discusses the scientific works containing results of research in the field of electrical, include ...