Proceeding of the Electrical Engineering Computer Science and Informatics
Vol 1: EECSI 2014

Technique and Device to Evaluate Lightning Air Terminal Collection Volume

Zainuddin Nawawi (Department of Electrical Engineering, Faculty of Engineering, Universitas Sriwijaya, Sumatera Selatan)
Hussein Ahmad (Institute of High Voltage and High Current (IVAT) Universiti Teknologi Malaysia, Johor)
Muhammad Abu Bakar Sidik (Institute of High Voltage & High Current (IVAT), Facuty of Electrical Engineering, Universiti Teknologi Malaysia (UTM), Malaysia Department of Electrical Engineering, Faculty of Engineering, Universitas Sriwijaya, Sumatera Selatan)
Lim Pai Hung (Institute of High Voltage and High Current (IVAT) Universiti Teknologi Malaysia, Johor)
Aulia . (Institute of High Voltage and High Current (IVAT) Universiti Teknologi Malaysia, Johor)
Hamizah Shahroom (Institute of High Voltage and High Current (IVAT) Universiti Teknologi Malaysia, Johor)
Muhammad ‘Irfan Jambak (Department of Electrical Engineering, Faculty of Engineering, Universitas Sriwijaya, Sumatera Selatan, Indonesia)



Article Info

Publish Date
20 Aug 2014

Abstract

Lightning air terminals are a very significant part of lightning protection system (LPS) for buildings, structures and facilities. With reference to the facilities requiring lightning protection the position, the apparent height, and the angle of protection of lightning air terminals determines the collection volume (CV) of the protected area. The CV of direct strike lightning air terminals can change due to facilities which are affected by natural disasters such as seismic tremor and flood. If such natural disasters do happen, there are possibilities that the facilities will not be fully protected from direct lightning strikes due to building and structure misalignment the aftermath of seismic tremor and flood related earth movement. So for the safety of equipment and personnel, lightning protection system efficacy assurance is necessary. Therefore, there should be a technique and device to monitor the variation of collection volume afforded by every lightning air terminal on buildings and structures after the occurrence of a natural disaster. This paper presents a new technique as well as a new device to monitor the collection volume variation. A part of the device was obtained from a recycled moveable television antenna. This approach is not only practical, portable and cost effective but also incorporating the idea of environmental protection and recycling of used plastic materials.

Copyrights © 2014






Journal Info

Abbrev

EECSI

Publisher

Subject

Computer Science & IT Electrical & Electronics Engineering

Description

Proceeding of the Electrical Engineering Computer Science and Informatics publishes papers of the "International Conference on Electrical Engineering Computer Science and Informatics (EECSI)" Series in high technical standard. The Proceeding is aimed to bring researchers, academicians, scientists, ...