Civil Engineering Dimension
Vol. 20 No. 2 (2018): SEPTEMBER 2018

Initial Surface Absorption of Cement Combination Concrete

Samuel Olufemi Folagbade (Department of Building, Faculty of Environmental Design and Management, Obafemi Awolowo University, Ile-Ife, 0220005, NIGERIA)



Article Info

Publish Date
08 Oct 2018

Abstract

This paper investigated the initial surface absorption (ISAT) of concrete using Portland cement (PC) and some binary and ternary cement combinations containing fly ash (FA), silica fume (SF) and metakaolin (MK) as partial replacements for PC at equal water/ cement ratios and strengths. At equal water/cement ratios, the cement combination concretes have higher ISAT values than PC concrete at 28 days and the disparity reduced with increasing curing age due to improved pozzolanic reactivity of the supplementary cementitious materials. SF and MK as binary and ternary cement components performed better than FA due to their higher fineness, improved particle packing and higher pozzolanic reactivity. At equal strengths, FA binary cement concretes have the lowest ISAT values and these reduced with increasing content of FA. At total replacement levels more than 20%, all the ternary cement concretes have lower ISAT values than PC concrete and the values reduced with increasing total replacement level due to the beneficial effect of FA.

Copyrights © 2018